Objectives This in vitro study examined the effect of different implant drilling template designs on heat generation during osteotomy and on cooling fluid distribution. Material and methods Five different template designs were investigated in a standardized setup against a control group and a negative control group: Occlusal-splint-design (OSD), OSD-covering, OSD-lateral opening, Bar design, and Orientation template. Pilot and one consecutive drill were run at 800 rpm with external irrigation and 2-kg load. Thermocouples recorded temperature changes at depths of 3, 6, and 9 mm in a bovine rib model. In the second experimental setup, the drill channel of one rib sample was perforated, and the irrigation volume passing through the drill channel was collected separately over time. Results Following mean temperature rises occurred [in degrees C]: control, 4.9; negative control, 12; OSD, 5.6; OSD-covering, 4.7; OSD-lateral opening, 3.8; Bar design, 5.1; and Orientation template, 4.9. The highest temperature increases were found at a drilling depth of 6 mm (p < .006). The 2.2-mm drill resulted in a significantly higher temperature rise than the 2.8-mm drill (p < .001). The mean volume (ml/min) of irrigation through the drill channel was Control group-flow, 28.5; OSD, 4.1; OSD-covering, 2; OSD-lateral opening; 5.8; bar design, 4; and Orientation template, 24.1. Conclusion Within the limitations, it was shown that fully guided drilling templates reduce the amount of cooling liquid at the point of osteotomy. The template design had an influence on the effective volume of the cooling liquid. However, this did not seem to increase the intraosseous temperature significantly.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 22 条
  • [1] External cooling efficiently controls intraosseous temperature rise caused by drilling in a drilling guide system: an in vitro study
    Boa, Kristof
    Varga, Endre, Jr.
    Pinter, Gabor
    Csonka, Akos
    Gargyan, Istvan
    Varga, Endre
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2015, 53 (10) : 963 - 967
  • [2] 10-Year Survival and Success Rates of 511 Titanium Implants with a Sandblasted and Acid-Etched Surface: A Retrospective Study in 303 Partially Edentulous Patients
    Buser, Daniel
    Janner, Simone F. M.
    Wittneben, Julia-Gabriela
    Braegger, Urs
    Ramseier, Christoph A.
    Salvi, Giovanni E.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) : 839 - 851
  • [3] Incidental findings of implant complications on postimplantation CBCTs: A cross-sectional study
    Clark, Danielle
    Barbu, Horia
    Lorean, Adi
    Mijiritsky, Eitan
    Levin, Liran
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 776 - 782
  • [4] Measurement of thermal conductivity of bovine cortical bone
    Davidson, SRH
    James, DF
    [J]. MEDICAL ENGINEERING & PHYSICS, 2000, 22 (10) : 741 - 747
  • [5] Evaluation of Bone Heating, Drill Deformation, and Drill Roughness After Implant Osteotomy: Guided Surgery and Classic Drilling Procedure
    dos Santos, Pamela Leticia
    Queiroz, Thallita Pereira
    Margonar, Rogerio
    Gomes de Souza Carvalho, Abrahao Cavalcante
    Betoni, Walter, Jr.
    Rodrigues Rezende, Regis Rocha
    dos Santos, Paulo Henrique
    Garcia, Idelmo Rangel, Jr.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 51 - 58
  • [6] TEMPERATURE THRESHOLD LEVELS FOR HEAT-INDUCED BONE TISSUE-INJURY - A VITAL-MICROSCOPIC STUDY IN THE RABBIT
    ERIKSSON, AR
    ALBREKTSSON, T
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (01) : 101 - 107
  • [7] Fortin T, 2009, INT J ORAL MAX IMPL, V24, P96
  • [8] Comparison of heat generation between guided and conventional implant surgery for single and sequential drilling protocols-An in vitro study
    Froesch, Leonie
    Mukaddam, Khaled
    Filippi, Andreas
    Zitzmann, Nicola U.
    Kuehl, Sebastian
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (02) : 121 - 130
  • [9] The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: an exvivo study
    Gehrke, Sergio Alexandre
    Aramburu Junior, Jaime Sarda
    Martinez, Carlos Perez-Albacete
    Ramirez Fernandez, Maria Piedad
    Mate Sanchez de Val, Jose Eduardo
    Calvo-Guirado, Jose Luis
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (07) : 772 - 778
  • [10] Intraosseous Temperature Changes During Implant Site Preparation: In Vitro Comparison of Thermocouples and Infrared Thermography
    Harder, Soenke
    Egert, Christopher
    Freitag-Wolf, Sandra
    Mehl, Christian
    Kern, Matthias
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 72 - 78