Simple and sensitive detection cell for capillary electrophoresis-chemiluminescence analysis using peroxyoxalate reagent

被引:0
|
作者
Tsukagoshi, K [1 ]
Otsuka, M
Hashimoto, M
Nakajima, R
Kimoto, H
机构
[1] Doshisha Univ, Fac Engn, Dept Chem Engn & Mat Sci, Kyoto 6100321, Japan
[2] Kimoto Ekectr Co Ltd, Tennoji Ku, Osaka 5430024, Japan
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Simple and conveniens batch-type detection cells were developed for the capillary electrophoresis with chemiluminescence detection using peroxyoxalate reagent. A fused-silica capillary was directly inserted into the cell, and a grounding electrode was also done into it. The cell could be easily combined with capillary electrophoresis without any complex construction and expensive implements. A mixture of Dnsyl-amino acids was satisfactorily separated. Dnsyl-Trp was detected with the detection limit of 1 x 10(-8) M by use of a glass cuvette-type cell.
引用
收藏
页码:98 / 99
页数:2
相关论文
共 50 条
  • [31] Development of a compact capillary electrophoresis-chemiluminescence system with ultra-fast peroxyoxalate reaction to monitor the hydrolysis of rhodamine 6G
    Zhu, Jinkun
    Shu, Lu
    Zhang, Fan
    Li, Zicheng
    Wang, Qingjiang
    He, Pingang
    Fang, Yuzhi
    LUMINESCENCE, 2012, 27 (06) : 482 - 488
  • [32] Determination of Sulfonamides Residues in Food by Capillary Zone Electrophoresis-Chemiluminescence Method
    Dai Ting-Ting
    Lin Hua-Ping
    Duan Jie
    Xu Xiang-Dong
    Shi Hong-Mei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (05) : 747 - 753
  • [33] Use of capillary electrophoresis with chemiluminescence detection for sensitive determination of homocysteine
    Mu, Xiaomei
    Zhao, Shulin
    Huang, Yong
    Ye, Fanggui
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (02) : 280 - 285
  • [34] HIGHLY SENSITIVE DETECTION OF PROTEINS SEPARATED BY CAPILLARY ZONE ELECTROPHORESIS USING ONLINE CHEMILUMINESCENCE DETECTION
    HARA, T
    NISHIDA, H
    NAKAJIMA, R
    ANALYTICAL SCIENCES, 1994, 10 (05) : 823 - 825
  • [35] Capillary electrophoresis with chemiluminescence detector using on-capillary detection
    Tsukagoshi, K
    Fujii, T
    Nakajima, R
    CHEMISTRY LETTERS, 2004, 33 (08) : 1000 - 1001
  • [36] PEROXYOXALATE CHEMILUMINESCENCE DETECTION WITH CAPILLARY LIQUID-CHROMATOGRAPHY
    WEBER, AJ
    GRAYESKI, ML
    ANALYTICAL CHEMISTRY, 1987, 59 (10) : 1452 - 1457
  • [37] Chemiluminescence detection for capillary electrophoresis and microchip capillary electrophoresis
    Huang, XY
    Ren, JC
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (02) : 155 - 166
  • [38] CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS
    DADOO, R
    COLON, LA
    ZARE, RN
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1992, 15 (02): : 133 - 135
  • [39] CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS
    BAEYENS, WRG
    LING, BL
    IMAI, K
    CALOKERINOS, AC
    SCHULMAN, SG
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (03) : 195 - 206
  • [40] Chemiluminescence detection in capillary electrophoresis
    Staller, TD
    Sepaniak, MJ
    ELECTROPHORESIS, 1997, 18 (12-13) : 2291 - 2296