Simple and sensitive detection cell for capillary electrophoresis-chemiluminescence analysis using peroxyoxalate reagent

被引:0
|
作者
Tsukagoshi, K [1 ]
Otsuka, M
Hashimoto, M
Nakajima, R
Kimoto, H
机构
[1] Doshisha Univ, Fac Engn, Dept Chem Engn & Mat Sci, Kyoto 6100321, Japan
[2] Kimoto Ekectr Co Ltd, Tennoji Ku, Osaka 5430024, Japan
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Simple and conveniens batch-type detection cells were developed for the capillary electrophoresis with chemiluminescence detection using peroxyoxalate reagent. A fused-silica capillary was directly inserted into the cell, and a grounding electrode was also done into it. The cell could be easily combined with capillary electrophoresis without any complex construction and expensive implements. A mixture of Dnsyl-amino acids was satisfactorily separated. Dnsyl-Trp was detected with the detection limit of 1 x 10(-8) M by use of a glass cuvette-type cell.
引用
收藏
页码:98 / 99
页数:2
相关论文
共 50 条
  • [1] PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS
    WU, NA
    HUIE, CW
    JOURNAL OF CHROMATOGRAPHY, 1993, 634 (02): : 309 - 315
  • [2] Development and Evaluation of a Rotary Cell for Capillary Electrophoresis-Chemiluminescence Detection
    Wang, Junhua
    Li, Linmei
    Huang, Weihua
    Cheng, Jieke
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5380 - 5383
  • [3] Peroxyoxalate chemiluminescence detection for capillary electrophoresis using membrane collection
    Shultz, LL
    Shippy, S
    Nieman, TA
    Sweedler, JV
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (04) : 329 - 337
  • [4] Compact detection cell using optical fiber for sensitization and simplification of capillary electrophoresis-chemiluminescence detection
    Hashimoto, M
    Tsukagoshi, K
    Nakajima, R
    Kondo, K
    JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) : 191 - 202
  • [5] Batch-type detection cell using a peroxyoxalate chemiluminescence system for capillary electrophoresis
    Dept. of Chem. Eng. and Mat. Science, Faculty of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan
    Anal. Sci., 12 (1257-1260):
  • [6] Batch-type detection cell using a peroxyoxalate chemiluminescence system for capillary electrophoresis
    Tsukagoshi, K
    Otsuka, M
    Hashimoto, M
    Nakajima, R
    Kondo, K
    ANALYTICAL SCIENCES, 1999, 15 (12) : 1257 - 1260
  • [7] Batch-Type Detection Cell Using a Peroxyoxalate Chemiluminescence System for Capillary Electrophoresis
    Kazuhiko Tsukagoshi
    Miwa Otsuka
    Masahiko Hashimoto
    Riichiro Nakajima
    Kazuo Kondo
    Analytical Sciences, 1999, 15 : 1257 - 1260
  • [8] Improvement of a capillary electrophoresis-chemiluminescence detection system for using a polyacrylamide-coated capillary
    Tsukagoshi, K
    Kimura, T
    Fuji, T
    Nakajima, R
    Arai, A
    ANALYTICAL SCIENCES, 2001, 17 (02) : 345 - 347
  • [9] Direct detection of biomolecules in a capillary electrophoresis-chemiluminescence detection system
    Tsukagoshi, K
    Nakahama, K
    Nakajima, R
    ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4410 - 4415
  • [10] Simple and convenient cell for chemiluminescence detection in capillary electrophoresis
    Dept. of Chem. Eng. and Mat. Science, Faculty of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan
    Anal. Sci., 11 (1047-1048):