摘要
The center of mass (CoM) and the center of pressure (CoP) are two variables that are crucial in assessing energy expenditure and stability of human walking. The purpose of this study is to estimate the CoM displacement continuously using an ambulatory measurement system. The measurement system consists of instrumented shoes with 6 DOF force/moment sensors beneath the heels and the forefeet. Moreover, two inertial sensors are rigidly attached to the force/moment sensors for the estimation of position and orientation. The estimation of CoM displacement is achieved by fusing low-pass filtered Col? data with high-pass filtered double integrated CoM acceleration, both estimated using the instrumented shoes. Optimal cutoff frequencies for the low-pass and high-pass filters appeared to be 0.2 Hz for the horizontal direction and 0.5 Hz for the vertical direction. The CoM estimation using this ambulatory measurement system was compared to CoM estimation using an optical reference system based on the segmental kinematics method. The rms difference of each component of the CoM displacement averaged over a hundred trials obtained from seven stroke patients was (0.020 +/- 0.007) m (mean standard deviation) for the forward x-direction, (0.013 +/- 0.005) m for the lateral y-direction, and (0.007 +/- 0.001) m for the upward z-direction. Based on the results presented in this study, it is concluded that the instrumented shoe concept allows accurate and continuous estimation of CoM displacement under ambulatory conditions.
引用
收藏
页码:1189 / 1195
页数:7
相关论文
共 28 条
[1]  
Benda B. J., 1994, IEEE Transactions on Rehabilitation Engineering, V2, P3, DOI 10.1109/86.296348
[3]   Why we walk the way we do [J].
Breniere, Y .
JOURNAL OF MOTOR BEHAVIOR, 1996, 28 (04) :291-298
[4]   Estimating the centre of gravity of the body on the basis of the centre of pressure in standing posture [J].
Caron, O ;
Faure, B ;
Brenière, Y .
JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) :1169-1171
[5]   FORCE PLATFORMS AS ERGOMETERS [J].
CAVAGNA, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (01) :174-179
[6]  
CHANDLER RF, 1975, HS801430 DOT NAT TEC
[7]   Simultaneous positive and negative external mechanical work in human walking [J].
Donelan, JM ;
Kram, R ;
Kuo, AD .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :117-124
[8]   Comparing methods of estimating the total body centre of mass in three-dimensions in normal and pathological gaits [J].
Eames, MHA ;
Cosgrove, A ;
Baker, R .
HUMAN MOVEMENT SCIENCE, 1999, 18 (05) :637-646
[9]   Comparison of kinematic and kinetic methods for computing the vertical motion of the body center of mass during walking [J].
Gard, SA ;
Miff, SC ;
Kuo, AD .
HUMAN MOVEMENT SCIENCE, 2004, 22 (06) :597-610
[10]   Comparison and evaluation of two common methods to measure center of mass displacement in three dimensions during gait [J].
Gutierrez-Farewik, Elena M. ;
Bartonek, sa ;
Saraste, Helena .
HUMAN MOVEMENT SCIENCE, 2006, 25 (02) :238-256