Cluster stability in the analysis of mass cytometry data

被引:19
作者
Melchiotti, Rossella [1 ,2 ]
Gracio, Filipe [1 ,2 ]
Kordasti, Shahram [3 ]
Todd, Alan K. [1 ,2 ]
de Rinaldis, Emanuele [1 ,2 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, 16th Floor,Tower Wing Guys Hosp, London SE1 9RT, England
[2] Kings Coll London, Translat Bioinformat Platform, R&D Dept, Biomed Res Ctr, London SE1 9RT, England
[3] Kings Coll London, Rayne Inst, Canc Studies Div, Dept Haematol Med, London SE5 9NU, England
关键词
CyTOF; data analysis; automated clustering; cluster stability; SPADE; PhenoGraph; FLOCK; AUTOMATED IDENTIFICATION; CELL SUBSETS; IMMUNE;
D O I
10.1002/cyto.a.23001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Manual gating has been traditionally applied to cytometry data sets to identify cells based on protein expression. The advent of mass cytometry allows for a higher number of proteins to be simultaneously measured on cells, therefore providing a means to define cell clusters in a high dimensional expression space. This enhancement, whilst opening unprecedented opportunities for single cell-level analyses, makes the incremental replacement of manual gating with automated clustering a compelling need. To this aim many methods have been implemented and their successful applications demonstrated in different settings. However, the reproducibility of automatically generated clusters is proving challenging and an analytical framework to distinguish spurious clusters from more stable entities, and presumably more biologically relevant ones, is still missing. One way to estimate cell clusters' stability is the evaluation of their consistent re-occurrence within- and between-algorithms, a metric that is commonly used to evaluate results from gene expression. Herein we report the usage and importance of cluster stability evaluations, when applied to results generated from three popular clustering algorithms - SPADE, FLOCK and PhenoGraph - run on four different data sets. These algorithms were shown to generate clusters with various degrees of statistical stability, many of them being unstable. By comparing the results of automated clustering with manually gated populations, we illustrate how information on cluster stability can assist towards a more rigorous and informed interpretation of clustering results. We also explore the relationships between statistical stability and other properties such as clusters' compactness and isolation, demonstrating that whilst cluster stability is linked to other properties it cannot be reliably predicted by any of them. Our study proposes the introduction of cluster stability as a necessary checkpoint for cluster interpretation and contributes to the construction of a more systematic and standardized analytical framework for the assessment of cytometry clustering results. (c) 2016 International Society for Advancement of Cytometry
引用
收藏
页码:73 / 84
页数:12
相关论文
共 50 条
  • [31] Flow Plex-A tool for unbiased comprehensive flow cytometry data analysis
    Nowatzky, Johannes
    Resnick, Ezra
    Manasson, Julia
    Stagnar, Cristy
    Al-Obeidi, Arshed Fahad
    Manches, Olivier
    IMMUNITY INFLAMMATION AND DISEASE, 2019, 7 (03) : 105 - 111
  • [32] Multiparameter Analysis of Stimulated Human Peripheral Blood Mononuclear Cells: A Comparison of Mass and Fluorescence Cytometry
    Nicholas, Katherine J.
    Greenplate, Allison R.
    Flaherty, David K.
    Matlock, Brittany K.
    Juan, Juan San
    Smith, Rita M.
    Irish, Jonathan M.
    Kalams, Spyros A.
    CYTOMETRY PART A, 2016, 89A (03) : 271 - 280
  • [33] BCyto: A shiny app for flow cytometry data analysis
    Bonilha, Caio Santos
    MOLECULAR AND CELLULAR PROBES, 2022, 65
  • [34] Data Analysis in Flow Cytometry: The Future Just Started
    Lugli, Enrico
    Roederer, Mario
    Cossarizza, Andrea
    CYTOMETRY PART A, 2010, 77A (07) : 705 - 713
  • [35] Comparison of Batch Effect Removal Methods for High Dimensional Mass Cytometry Data
    Suwalska, Aleksandra
    du Plessis-Burger, Nelita
    van der Spuy, Gian
    Polanska, Joanna
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING, PT II, 2022, : 399 - 410
  • [36] Platinum-conjugated Antibodies for Application in Mass Cytometry
    Mei, Henrik E.
    Leipold, Michael D.
    Maecker, Holden T.
    CYTOMETRY PART A, 2016, 89A (03) : 292 - 300
  • [37] Single-cell Analysis of Immunophenotype and Cytokine Production in Peripheral Whole Blood via Mass Cytometry
    Baxter, Ryan M.
    Kong, Daniel S.
    Garcia-Perez, Josselyn E.
    O'Gorman, William E.
    Hsieh, Elena W. Y.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (136):
  • [38] Analysis of cell surface and intranuclear markers on non-stimulated human PBMC using mass cytometry
    Dzangue-Tchoupou, Gaelle
    Corneau, Aurelien
    Blanc, Catherine
    Benveniste, Olivier
    Allenbach, Yves
    PLOS ONE, 2018, 13 (03):
  • [39] Dual-labelled antibodies for flow and mass cytometry: A new tool for cross-platform comparison and enrichment of target cells for mass cytometry
    Baumgart, Sabine
    Schulz, Axel R.
    Peddinghaus, Anette
    Stanislawiak, Silke
    Gillert, Sarah
    Hirseland, Heike
    Krauthaeuser, Susanne
    Dose, Christian
    Mei, Henrik E.
    Gruetzkau, Andreas
    EUROPEAN JOURNAL OF IMMUNOLOGY, 2017, 47 (08) : 1377 - 1385
  • [40] SwiftReg cluster registration automatically reduces flow cytometry data variability including batch effects
    Rebhahn, Jonathan A.
    Quataert, Sally A.
    Sharma, Gaurav
    Mosmann, Tim R.
    COMMUNICATIONS BIOLOGY, 2020, 3 (01)