Electrochemical sensor based on molecularly imprinted polymer/reduced graphene oxide composite for simultaneous determination of uric acid and tyrosine

被引:101
作者
Zheng, Weihua [1 ]
Zhao, Min [1 ]
Liu, Weifen [1 ]
Yu, Shangmin [1 ]
Niu, Liting [1 ]
Li, Gengen [1 ]
Li, Haifeng [1 ]
Liu, Weilu [1 ]
机构
[1] Shenyang Pharmaceut Univ, Sch Pharm, Shenyang 110016, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
Molecularly imprinted polymer; Reduced graphene oxide; 2-amino-5-mercapto-1; 3; 4-thiadiazole; Uric acid; Tyrosine; GLASSY-CARBON ELECTRODE; BIOLOGICAL-FLUIDS; COPOLYMER; DOPAMINE; POLYMERS; FILMS;
D O I
10.1016/j.jelechem.2018.02.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reported a molecularly imprinted polymer (MIP)/reduced graphene oxide (RGO) composite for simultaneous determination of uric acid and tyrosine. The MW layer was electropolymerized on the RGO modified electrode using a novel monomer of 2-amino-5-mercapto-1, 3, 4-thiadiazole and the dual template of uric acid and tyrosine. The integration of MIP with RGO resulted in the regular nanostructure and large surface area of the sensing interface. The sensing mechanism of the sensor can be explained by first recognizing the target molecules and then catalyzing the oxidation reactions on the MIP/RGO composite. The, electrochemical behavior of uric acid and tyrosine on the MIP/RGO composite was evaluated. Influencing factors, including the electropolymerization scanning cycles, monomer/template ratio, and pH values were optimized. Under the optimal condition, the sensor exhibits wide linear ranges for uric acid (0.01 mu M-100 mu M) and tyrosine (0.1 mu M-400 mu M) with detection limits of 0.0032 mu M and 0.046 mu M, respectively. In addition, this MIP/RGO composite was applied to detect uric acid and tyrosine in serum and urine samples.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 35 条
[21]   Hierarchical polystyrene@reduced graphene oxide-Pt core-shell microspheres for nonenzymatic detection of hydrogen peroxide [J].
Liu, Weilu ;
Li, Cong ;
Zhang, Peng ;
Tang, Liu ;
Gu, Yue ;
Zhang, Yujing ;
Zhang, Jianqing ;
Liu, Zhongbo ;
Sun, Guoxiang ;
Zhang, Zhiquan .
RSC ADVANCES, 2015, 5 (90) :73993-74002
[22]   A novel electrochemical sensor based on a molecularly imprinted polymer for the determination of epigallocatechin gallate [J].
Liu, Yanrui ;
Zhu, Lili ;
Hu, Yue ;
Peng, Xinsheng ;
Du, Jiangyan .
FOOD CHEMISTRY, 2017, 221 :1128-1134
[23]   Preparation of molecularly imprinted polymeric microspheres based on distillation-precipitation polymerization for an ultrasensitive electrochemical sensor [J].
Liu, Yuan ;
Zhang, Lu ;
Zhao, Na ;
Han, Yajie ;
Zhao, Feilang ;
Peng, Zhengchun ;
Li, Yingchun .
ANALYST, 2017, 142 (07) :1091-1098
[24]  
MAPLES KR, 1988, J BIOL CHEM, V263, P1709
[25]   Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode [J].
Motghare, Ramani V. ;
Tadi, Kiran Kumar ;
Dhawale, Payal ;
Deotare, Samiksha ;
Kawadkar, Aruna K. ;
Chillawar, Rakesh ;
Khan, Shirinaz .
ELECTROANALYSIS, 2015, 27 (03) :825-832
[26]   Electric field effect in atomically thin carbon films [J].
Novoselov, KS ;
Geim, AK ;
Morozov, SV ;
Jiang, D ;
Zhang, Y ;
Dubonos, SV ;
Grigorieva, IV ;
Firsov, AA .
SCIENCE, 2004, 306 (5696) :666-669
[27]   Simultaneous determination of vitamins B2, B9 and C using a heterocyclic conducting polymer modified electrode [J].
Revin, S. Brillians ;
John, S. Abraham .
ELECTROCHIMICA ACTA, 2012, 75 :35-41
[28]   Electropolymerization of 3-amino-5-mercapto-1,2,4-triazole on glassy carbon electrode and its electrocatalytic activity towards uric acid [J].
Revin, S. Brillians ;
John, S. Abraham .
ELECTROCHIMICA ACTA, 2011, 56 (24) :8934-8940
[29]   Ultraviolet absorption spectra of nitrogenous heterocycles VII The effect of hydroxy substitutions on the ultraviolet absorption of the series hypoxanthine, xanthine and uric acid [J].
Stimson, MM ;
Reuter, MA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1943, 65 :153-155
[30]   Fabrication of Ni-Fe2O3 magnetic nanorods and application to the detection of uric acid [J].
Suresh, R. ;
Giribabu, K. ;
Manigandan, R. ;
Stephen, A. ;
Narayanan, V. .
RSC ADVANCES, 2014, 4 (33) :17146-17155