Amperometric bienzyme electrodes with horseradish peroxidase (HRP) and glucose oxidase (GOx) co-immobilized on polymethylferrocenyl dendrimers deposited onto platinum electrodes have been used for determination of the hydrogen peroxide produced by the oxidase during the enzymatic reaction. The redox dendrimers consist of flexible poly(propylenimine) dendrimer cores functionalised with octamethylferrocenyl units. The effects of dendrimer generation, the thickness of the dendrimer layer, substrate concentration, interferences, and reproducibility on the response of the sensors were investigated. The new bienzyme biosensors respond to substrate at work potential values between 200 and 50 mV (vs. SCE), have good sensitivity, and are resistant to interferences.
引用
收藏
页码:1209 / 1217
页数:9
相关论文
共 42 条
  • [1] Preparation of biosensors based in a siloxane homopolymer with interacting ferrocenes for the amperometric detection of peroxides
    Armada, MPG
    Losada, J
    Cuadrado, I
    Alonso, B
    González, B
    Casado, CM
    Zhang, JB
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2) : 143 - 149
  • [2] Armada MPG, 2003, SENSOR ACTUAT B-CHEM, V88, P190, DOI 10.1016/S0925-4005(02)00326-X
  • [3] ARMADA MPG, IN PRESS BIOELECTROC
  • [4] THIN-FILM BIENZYME AMPEROMETRIC BIOSENSORS BASED ON POLYMERIC REDOX MEDIATORS WITH ELECTROSTATIC BIPOLAR PROTECTING LAYER
    BOGUSLAVSKY, L
    KALASH, H
    XU, Z
    BECKLES, D
    GENG, L
    SKOTHEIM, T
    LAURINAVICIUS, V
    LEE, HS
    [J]. ANALYTICA CHIMICA ACTA, 1995, 311 (01) : 15 - 21
  • [5] CARDOSI MF, 1991, ADV BIOSENSORS MEDIA, V1
  • [6] Redox-active ferrocenyl dendrimers and polymers in solution and immobilised on electrode surfaces
    Casado, CM
    Cuadrado, I
    Morán, M
    Alonso, B
    García, B
    González, B
    Losada, J
    [J]. COORDINATION CHEMISTRY REVIEWS, 1999, 185-6 : 53 - 79
  • [7] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [8] Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode
    Charpentier, L
    ElMurr, N
    [J]. ANALYTICA CHIMICA ACTA, 1995, 318 (01) : 89 - 93
  • [9] POLYMERIC REDOX MEDIATOR ENZYME ELECTRODES FOR ANAEROBIC GLUCOSE MONITORING
    CHEN, CJ
    LIU, CC
    SAVINELL, RF
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 348 (1-2): : 317 - 338
  • [10] Cosnier S, 2000, ELECTROANAL, V12, P356, DOI 10.1002/(SICI)1521-4109(20000301)12:5<356::AID-ELAN356>3.3.CO