A low-cost miniaturized potentiostat for point-of-care diagnosis

被引:129
作者
Cruz, Andres Felipe Diaz [1 ]
Norena, Nicolas [1 ]
Kaushik, Ajeet [2 ]
Bhansali, Shekhar [1 ]
机构
[1] Florida Int Lab, BioMEMS Microsyst Lab, Miami, FL 33174 USA
[2] Florida Int Univ, Herbert Wertheim Coll Med, Inst Neuroimmune Pharmacol, Ctr Personalized Nanomed,Dept Immunol, Miami, FL 33199 USA
关键词
Miniaturized potentiostat; Point-of-care; Personalized health monitoring/diagnostic; Electrochemical immunosensing; Cortisol; INTERDIGITATED ARRAY MICROELECTRODES; PORTABLE POTENTIOSTAT; LABEL-FREE; BIOSENSORS; TECHNOLOGIES; SENSORS; SYSTEMS; DESIGN;
D O I
10.1016/j.bios.2014.06.053
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a novel approach of using a miniaturized potentiostat (M-P) chip (LMP91000) to perform full range cyclic voltammetry (CV) measurements for the detection of biomarkers. The LMP91000 evaluation board was reconfigured to perform three-electrode CV measurements in order to achieve electrochemical cortisol immunosensing. The microelectrodes for cortisol estimation were fabricated by immobilizing monoclonal anti-cortisol antibody (Anti-M-Cab) onto self-assembled monolayer (SAM) modified Au microelectrodes. The results obtained using the M-P were compared to those obtained using a conventional potentiostat. The M-P was successful in measuring cortisol levels in the range of pM. The outcomes of the studies suggest that M-P can effectively perform biochemical measurements on three electrode systems, enabling the development of miniature systems for point-of-care (POC) diagnosis. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:249 / 254
页数:6
相关论文
共 36 条
[1]   Disposable Smart lab on a chip for point-of-care clinical diagnostics [J].
Ahn, CH ;
Choi, JW ;
Beaucage, G ;
Nevin, JH ;
Lee, JB ;
Puntambekar, A ;
Lee, JY .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :154-173
[2]   Recent advances in ZnO nanostructures and thin films for biosensor applications: Review [J].
Arya, Sunil K. ;
Saha, Shibu ;
Ramirez-Vick, Jaime E. ;
Gupta, Vinay ;
Bhansali, Shekhar ;
Singh, Surinder P. .
ANALYTICA CHIMICA ACTA, 2012, 737 :1-21
[3]   Antibody functionalized interdigitated μ-electrode (IDμE) based impedimetric cortisol biosensor [J].
Arya, Sunil K. ;
Chornokur, Ganna ;
Venugopal, Manju ;
Bhansali, Shekhar .
ANALYST, 2010, 135 (08) :1941-1946
[4]   Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol [J].
Arya, Sunil K. ;
Chornokur, Ganna ;
Venugopal, Manju ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (10) :2296-2301
[5]   Design of a low-cost portable potentiostat for amperometric biosensor [J].
Blanco, J. R. ;
Ferrero, F. J. ;
Campo, J. C. ;
Anton, J. C. ;
Pingarron, J. M. ;
Reviejo, A. J. ;
Manso, J. .
2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, :690-+
[6]   Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins [J].
Choi, Seokheun ;
Goryll, Michael ;
Sin, Lai Yi Mandy ;
Wong, Pak Kin ;
Chae, Junseok .
MICROFLUIDICS AND NANOFLUIDICS, 2011, 10 (02) :231-247
[7]   Large-area interdigitated array microelectrodes for electrochemical sensing [J].
Cohen, AE ;
Kunz, RR .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (01) :23-29
[8]   Point of Care Diagnostics: Status and Future [J].
Gubala, Vladimir ;
Harris, Leanne F. ;
Ricco, Antonio J. ;
Tan, Ming X. ;
Williams, David E. .
ANALYTICAL CHEMISTRY, 2012, 84 (02) :487-515
[9]   A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprinting [J].
Huang, Chun-Yueh ;
Syu, Mei-Jywan ;
Chang, Yong-Shuen ;
Chang, Chih-Hung ;
Chou, Tse-Chuan ;
Liu, Bin-Da .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (08) :1694-1699
[10]   Optimized growth and integration of silica nanowires into interdigitated microelectrode structures for biosensing [J].
Huey, Eric ;
Krishnan, Subramanian ;
Arya, Sunil K. ;
Dey, Abhishek ;
Bhansali, Shekhar .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 175 :29-33