Sensitive indoor air monitoring of monoterpenes using different adsorbents and thermal desorption gas chromatography with mass-selective detection

被引:22
|
作者
Hollender, J [1 ]
Sandner, F [1 ]
Möller, M [1 ]
Dott, W [1 ]
机构
[1] Rhein Westfal TH Aachen Klinikum, Inst Hyg & Umweltmed, D-52074 Aachen, Germany
关键词
thermal desorption; air analysis; adsorbents; monoterpenes; terpenes;
D O I
10.1016/S0021-9673(02)00511-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method using active trapping on adsorbents and thermal desorption followed by GC-MS analysis was developed for the indoor air monitoring of monoterpenes. The study was carried out using a dynamically generated atmosphere consisting of 11 monoterpenes: camphene, camphor, Delta(3)-carene, 1,8-cineol, limonene, linalool, alpha-pinene, beta-pinene, alpha-terpinene, gamma-terpinene, fenchyl alcohol. The influence of the different adsorbents Tenax TA, Tenax GR, Carbosieve SIII, Chromosorb 106 on the yield of six selected monoterpenes at indoor air concentrations was studied. The adsorbent Tenax GR gave relatively the best yields followed by Tenax TA. Detection limits of approximately 1 mug m(3) were determined with Tenax GR for most of the monoterpenes. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 50 条