Methods to reduce the CO2 concentration of educational buildings utilizing internal ventilation by transferred air

被引:4
作者
Kalema, T. [1 ]
Viot, M. [1 ]
机构
[1] Tampere Univ Technol, FIN-33101 Tampere, Finland
关键词
Indoor air quality; CO2; concentration; Transferred air; School buildings; Internal openings; Modeling; Measurements;
D O I
10.1111/ina.12059
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this study is to develop internal ventilation by transferred air to achieve a good indoor climate with low energy consumption in educational buildings with constant air volume (CAV) ventilation. Both measurements of CO2 concentration and a multi-room calculation model are presented. The study analyzes how to use more efficiently the available spaces and the capacity of CAV ventilation systems in existing buildings and the impact this has on the indoor air quality and the energy consumption of the ventilation. The temperature differences can be used to create natural ventilation airflows between neighboring spaces. The behavior of temperature-driven airflows between rooms was studied and included in the calculation model. The effect of openings between neighboring spaces, such as doors or large apertures in the walls, on the CO2 concentration was studied in different classrooms. The air temperatures and CO2 concentrations were measured using a wireless, internet-based measurement system. The multi-room calculation model predicted the CO2 concentration in the rooms, which was then compared with the measured ones. Using transferred air between occupied and unoccupied spaces can noticeably reduce the total mechanical ventilation rates needed to keep a low CO2 concentration.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 50 条
  • [41] Use of Low-Cost Devices for the Control and Monitoring of CO2 Concentration in Existing Buildings after the COVID Era
    Pastor-Fernandez, Andres
    Cerezo-Narvaez, Alberto
    Montero-Gutierrez, Paz
    Ballesteros-Perez, Pablo
    Otero-Mateo, Manuel
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [42] Definition of Optimal Ventilation Rates for Balancing Comfort and Energy Use in Indoor Spaces Using CO2 Concentration Data
    Franco, Alessandro
    Schito, Eva
    BUILDINGS, 2020, 10 (08)
  • [43] Evaluation of the humidity performance of a carbon dioxide (CO2) capture device as a novel ventilation strategy in buildings
    Kim, Moon Keun
    Baldini, Luca
    Leibundgut, Hansjurg
    Wurzbacher, Jan Andre
    APPLIED ENERGY, 2020, 259
  • [44] Spatial Analysis of Mangrove Forest Management to Reduce Air Temperature and CO2 Emissions
    Sumarmi, Sumarmi
    Purwanto, Purwanto
    Bachri, Syamsul
    SUSTAINABILITY, 2021, 13 (14)
  • [45] Environmental effects of pig house ventilation controlled by animal activity and CO2 indoor concentration
    Haeussermann, A
    Hartung, E
    Jungbluth, T
    Precision Livestock Farming '05, 2005, : 57 - 64
  • [46] Evaluating the potential impact of global warming on the UAE residential buildings - A contribution to reduce the CO2 emissions
    Radhi, Hassan
    BUILDING AND ENVIRONMENT, 2009, 44 (12) : 2451 - 2462
  • [47] Amine-Based Latex Coatings for Indoor Air CO2 Control in Commercial Buildings
    Krishnamurthy, Anirudh
    Salunkhe, Buddhabhushan
    Zore, Ashish
    Rownaghi, Ali
    Schuman, Thomas
    Rezaei, Fateme
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (18) : 16594 - 16604
  • [48] Energy - Environmental methods to reduce CO2 emissions in Romanian iron and steel industry
    Melinte, Ion
    Balanescu, Mihaela
    RECENT ADVANCES IN ENERGY AND ENVIRONMENT: PROCEEDINGS OF THE 4TH IASME/WSEAS INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT (EE'09), 2009, : 195 - +
  • [49] CO2 concentration as an indicator of indoor ventilation performance to control airborne transmission of SARS-CoV-2
    Park, Sowoo
    Song, Doosam
    JOURNAL OF INFECTION AND PUBLIC HEALTH, 2023, 16 (07) : 1037 - 1044
  • [50] Production Ecophysiology of Hungarian Green Pepper Under Elevated Air CO2 Concentration
    Helyes, Lajos
    Tuba, Zoltan
    Balogh, Janos
    Reti, Katalin
    JOURNAL OF CROP IMPROVEMENT, 2005, 13 (1-2) : 333 - 344