Transient model of a vertical freezer with door openings and defrost effects

被引:31
作者
Mastrullo, R. [1 ]
Mauro, A. W. [1 ]
Menna, L. [1 ]
Palma, A. [1 ]
Vanoli, G. P. [2 ]
机构
[1] Univ Naples Federico II, Dipartimento Ingn Ind Sez ETEC, I-80125 Naples, Italy
[2] Univ Sannio, DING, I-82100 Benevento, Italy
关键词
Freezer; Temperature; Control; Frost; Defrost; Energy saving; TUBE HEAT-EXCHANGERS; FROST FORMATION; HOUSEHOLD REFRIGERATORS; PERFORMANCE; SIMULATION;
D O I
10.1016/j.apenergy.2014.01.069
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cabinet temperature evolution and energy consumption are two parameters of primary importance for food/medicals preservation and energy savings in cold appliances. In this paper, a transient model of a vertical freezer is developed to study the trend of cabinet temperature and of energy consumption with time, taking also into account door openings, air leakage, frost formation and defrost effect. The model is validated with the experimental data, both with in-house data and with data available in the open literature for frost formation. The results are presented with varying operating conditions, such as air temperature, air humidity, frequency of door opening and defrosting. A qualitative comparison of the trends of air temperature inside the cabinet and of power consumption showed a good agreement between the experimental and simulated profiles; a good agreement was also found in the statistical analysis of errors, with maximum absolute errors on the time averaged temperature of air inside the cabinet of the order of 4 K and maximum relative error on the time averaged power consumption of the order of 4%. Sensitivity analyses are reported as examples to exploit the potential of the model as a tool for design of systems, for settings for defrost parameters and for preventing fault events for food/medical preservation. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:38 / 50
页数:13
相关论文
共 36 条
  • [1] Developing new test procedures for domestic refrigerators: harmonisation issues and future R&D needs - a review
    Bansal, PK
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (07): : 735 - 748
  • [2] Thermal analysis of the defrost cycle in a domestic freezer
    Bansal, Pradeep
    Fothergill, David
    Fernandes, Ryan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (03): : 589 - 599
  • [3] WHEN TO DEFROST A REFRIGERATOR, AND WHEN TO REMOVE THE SCALE FROM THE HEAT-EXCHANGER OF A POWER-PLANT
    BEJAN, A
    VARGAS, JVC
    LIM, JS
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (03) : 523 - 532
  • [4] Transient simulation of household refrigerators: A semi-empirical quasi-steady approach
    Borges, Bruno N.
    Hermes, Christian J. L.
    Goncalves, Joaquim M.
    Melo, Claudio
    [J]. APPLIED ENERGY, 2011, 88 (03) : 748 - 754
  • [5] Building Energy Databook, 2010, US DAT YEAR
  • [6] Fan supplied heat exchanger fin performance under frosting conditions
    Chen, H
    Thomas, L
    Besant, RW
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01): : 140 - 149
  • [7] Chojnacky M., COLD CHAIN MANAGEMEN
  • [8] A new time- and space-dependent model for predicting frost formation
    Cui, J.
    Li, W. Z.
    Liu, Y.
    Jiang, Z. Y.
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (04) : 447 - 457
  • [9] Experimental study of frost accumulation on fan-supplied tube-fin evaporators
    da Silva, Diogo L.
    Hermes, Christian J. L.
    Melo, Claudio
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (6-7) : 1013 - 1020
  • [10] Modeling and performance analyses of evaporators in frozen-food supermarket display cabinets at low temperatures
    Getu, H. M.
    Bansal, P. K.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (07): : 1227 - 1243