Sensitive and selective electrochemical detection of Cd2+ by using bimetal oxide decorated Graphene oxide (Bi2O3/Fe2O3@GO) electrode

被引:42
作者
Das, Trupti R. [1 ]
Sharma, Prashant K. [1 ]
机构
[1] Indian Inst Technol, Indian Sch Mines, Dept Appl Phys, Funct Nanomat Res Lab, Dhanbad 826004, Jharkhand, India
关键词
Bi2O3/Fe2O3@GO; Electrocatalytic activity; Linear range; LOD; Sensitivity; Stability; ANODIC-STRIPPING VOLTAMMETRY; BISMUTH OXIDE; PHOTOCATALYTIC DEGRADATION; CARBON; COMPOSITE; CADMIUM; NANOCOMPOSITE; LEAD; SENSOR; FILM;
D O I
10.1016/j.microc.2019.04.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bimetal oxide decorated graphene oxide (Bi2O3/Fe2O3@GO) was synthesized by a simple hydrothermal method and used as an electrochemical sensor for sensing the toxic cadmium (Cd2+) ion. For comparative analysis graphene oxide (GO), Iron oxide nanoparticle decorated on GO sheets (Fe2O3@GO) and bismuth oxide nanoparticle decorated on GO sheets (Bi2O3@GO) were synthesized. Structurally and morphologically two different nanoparticles of Bi2O3 and Fe2O3 on GO sheets were confirmed from XRD, FESEM techniques respectively. Latter the inter planner spacing of the nanoparticles and GO sheets were calculated from the HRTEM techniques, which matched with the exact value obtained through XRD analysis. Functional groups like hydroxyl, epoxide, carbonyl, and carboxyl were investigated through FT-IR techniques. Detection of Cd2+ was performed through square wave voltammetry (SWV) technique with an optimized pH (5.0), deposition potential ( - 1.0 V) and deposition time (90 s). The Bi2O3/Fe2O3@GO modified electrode shows the better electro-catalytic property with more no. of active sites which facilitate the electron transfer between the electrode and species. The nanocomposite Bi2O3/Fe2O3@GO was found to be more sensitive than blank, GO, Fe2O3@GO and Bi2O3@GO modified electrodes. The Bi2O3/Fe2O3@GO modified electrode exhibits a linear range of 6.2 ng L-1 to 1160.2 ng L-1 and limit of detection of 1.85 ng L-1 towards the detection of Cd2+. A very high sensitivity of 2034.2 A cm(-2) g(-1) L was recorded for the Bi2O3/Fe2O3@GO electrode. The interference study explains the Bi2O3/Fe2O3@GO electrode is selective towards Cd2+ among various biomolecules and heavy metal ions. Real sample analysis study confirms the ability of the Bi2O3/Fe2O3@GO electrode for detecting Cd2+ present in water, fruits, soil, and biological samples. The Bi2O3/Fe2O3@GO electrode has good stability up to 40 days exhibiting without any current loss.
引用
收藏
页码:1203 / 1214
页数:12
相关论文
共 55 条
[1]   Photocatalytic degradation of paracetamol over magnetic flower-like TiO2/Fe2O3 core-shell nanostructures [J].
Abdel-Wahab, Aboel-Magd ;
Al-Shirbini, Al-Sayed ;
Mohamed, Omima ;
Nasr, Osama .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2017, 347 :186-198
[2]   Synthesis, structural and optical properties of gold nanoparticle-graphene-selenocysteine composite bismuth ultrathin film electrode and its application to Pb(II) and Cd(II) determination [J].
Al-Hossainy, Ahmed Farouk ;
Abd-Elmageed, A. A. I. ;
Ibrahim, Ahmed Th. A. .
ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (08) :2853-2863
[3]  
[Anonymous], 1980, ADV INORGANIC CHEM
[4]   A simple approach for simultaneous detection of cadmium(II) and lead(II) based on glutathione coated magnetic nanoparticles as a highly selective electrochemical probe [J].
Baghayeri, Mehdi ;
Amiri, Amirhassan ;
Maleki, Behrooz ;
Alizadeh, Zahra ;
Reiser, Oliver .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 :1442-1450
[5]   Covalently functionalized reduced graphene oxide by organically modified silica: a facile synthesis of electrically conducting black coatings on glass [J].
Bhowmik, Koushik ;
Pramanik, Sourav ;
Medda, Samar Kumar ;
De, Goutam .
JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (47) :24690-24697
[6]   Gold-coated nanostructured carbon tape for rapid electrochemical detection of cadmium in rice with in situ electrodeposition of bismuthin paper-based analytical devices [J].
Bi, Xiao-Mei ;
Wang, He-Ru ;
Ge, Li-Qiang ;
Zhou, Dong-Mei ;
Xu, Jin-Zhong ;
Gu, Hai-Ying ;
Bao, Ning .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 :475-479
[7]   A voltammetric sensor based on the glassy carbon electrode modified with multi-walled carbon nanotube/poly(pyrocatechol violet)/bismuth film for determination of cadmium and lead as environmental pollutants [J].
Chamjangali, M. Arab ;
Kouhestani, H. ;
Masdarolomoor, F. ;
Daneshinejad, H. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 :384-393
[8]   Molecular composition of iron oxide nanoparticles, precursors for magnetic drug targeting, as characterized by confocal Raman microspectroscopy [J].
Chourpa, I ;
Douziech-Eyrolles, L ;
Ngaboni-Okassa, L ;
Fouquenet, JF ;
Cohen-Jonathan, S ;
Soucé, M ;
Marchais, H ;
Dubois, P .
ANALYST, 2005, 130 (10) :1395-1403
[9]   Polymeric iron oxide-graphene nanocomposite as a trace level sensor of vitamin C [J].
Das, Trupti R. ;
Jena, Suchit Kumar ;
Madhuri, Rashmi ;
Sharma, Prashant K. .
APPLIED SURFACE SCIENCE, 2018, 449 :304-313
[10]   Bismuth oxide decorated graphene oxide nanocomposites synthesized via sonochemical assisted hydrothermal method for adsorption of cationic organic dyes [J].
Das, Trupti R. ;
Patra, Santanu ;
Madhuri, Rashmi ;
Sharma, Prashant K. .