Modeling of CO2 post-combustion capture using membrane contactors, comparison between one- and two-dimensional approaches

被引:36
作者
Zaidiza, David Albarracin [1 ]
Billaud, Joseph [1 ]
Belaissaoui, Bouchra [1 ]
Rode, Sabine [1 ]
Roizard, Denis [1 ]
Favre, Eric [1 ]
机构
[1] Univ Lorraine, ENSIC, Lab React & Genie Proc, UMR 7274, F-54001 Nancy, France
关键词
Carbon dioxide capture; Modeling; Hollow fiber membrane contactor; Reactive absorption; Intensification; CARBON-DIOXIDE ABSORPTION; GAS; REMOVAL;
D O I
10.1016/j.memsci.2013.12.012
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This work presents a numerical comparison between a one-dimensional and a two-dimensional model for CO2 capture through solvent absorption with chemical reaction in a hollow fiber membrane contactor. The relevance of the two approaches is discussed. Industrially relevant operational conditions of postcombustion capture using MEA as reactive solvent were applied for both models. Variable gas and liquid mass transfer resistances, depending on the concentrations and the fluids velocity, were employed for the one-dimensional approach, while differential mass balances considering convection, diffusion and reaction contributions were employed for the two-dimensional approach. The space averaged specific molar CO2 absorbed flux estimated by both models was almost identical, with a maximum relative difference of 5.735 for membrane permeabilities (epsilon/tau) comprised between 0.001 and 02 and external fiber radiuses comprised between 0.2 and 0.9 mm. Thus it turns out that the one-dimensional approach provides results similar to a two-dimensional approach in the investigated domain with significant lower calculation Limes. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 74
页数:11
相关论文
共 24 条
[1]  
[Anonymous], 2016, CARBON DIOXIDE CAPTU
[2]  
BEEK W J., 1999, Transport Phenomena
[3]   A modeling study on the effects of membrane characteristics and operating parameters on physical absorption of CO2 by hollow fiber membrane contactor [J].
Boributh, Somnuk ;
Assabumrungrat, Suttichai ;
Laosiripojana, Navadol ;
Jiraratananon, Ratana .
JOURNAL OF MEMBRANE SCIENCE, 2011, 380 (1-2) :21-33
[4]   Carbon dioxide absorption by monoethanolamine in hollow fiber membrane contactors: A parametric investigation [J].
Boucif, Noureddine ;
Corriou, Jean Pierre ;
Roizard, Denis ;
Favre, Eric .
AICHE JOURNAL, 2012, 58 (09) :2843-2855
[5]   Modeling strategies of membrane contactors for post-combustion carbon capture: A critical comparative study [J].
Chabanon, E. ;
Roizard, D. ;
Favre, E. .
CHEMICAL ENGINEERING SCIENCE, 2013, 87 :393-407
[6]  
Cheng S., 1996, HYDROCARBON PROCESS, V75
[7]   Modeling and simulation of CO2 removal from power plant flue gas by PG solution in a hollow fiber membrane contactor [J].
Eslami, S. ;
Mousavi, S. M. ;
Danesh, S. ;
Banazadeh, H. .
ADVANCES IN ENGINEERING SOFTWARE, 2011, 42 (08) :612-620
[8]   Significance of gas velocity change during the transport of CO2 through hollow fiber membrane contactors [J].
Faiz, Rami ;
El-Naas, Muftah. H. ;
Al-Marzouqi, M. .
CHEMICAL ENGINEERING JOURNAL, 2011, 168 (02) :593-603
[9]   VISCOUS FLOW RELATIVE TO ARRAYS OF CYLINDERS [J].
HAPPEL, J .
AICHE JOURNAL, 1959, 5 (02) :174-177
[10]   Modeling and experimental study of carbon dioxide absorption in aqueous alkanolamine solutions using a membrane contactor [J].
Hoff, KA ;
Juliussen, O ;
Falk-Pedersen, O ;
Svendsen, HF .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (16) :4908-4921