Measurement of the thermal conductivity of argon and methane:: a test of a transient hot-wire apparatus

被引:18
|
作者
Pátek, J [1 ]
Klomfar, J [1 ]
机构
[1] Acad Sci Czech Republ, Inst Thermomech, CZ-18200 Prague 8, Czech Republic
关键词
thermal conductivity; pure; transient hot-wire apparatus; argon; methane;
D O I
10.1016/S0378-3812(01)00763-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
A transient hot-wire apparatus for absolute measurements of the thermal conductivity of gases has been constructed and tested with argon and methane. The apparatus operates at temperatures from about 300 to 473 K and pressures up to 60MPa. To evaluate the capability of the apparatus. measurements were per-formed (i) with argon along five isotherms at temperatures between 300 and 425 K with pressures up to 15 MPa. and (ii) with methane along seven isotherms at temperatures between 290 and 360 K with pressures up to 15 MPa. The experimental thermal conductivity data and the results of their low-density analysis are compared with results of other investigators. The total experimental uncertainty of the measurements is estimated to be +/- 0.00 1 x p in pressure and +/- 0.005 K in temperature, The relative uncertainty of the measurements at 95% level is estimated to be 1.2% for argon and 0.7% for methane. The reproducibility of the results measured by the standard deviation from the polynomial lambda(rho) relation along isotherms is 0.3% for argon and 0.2% for methane. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:147 / 163
页数:17
相关论文
共 50 条
  • [21] Radiation effects in the transient hot-wire techniqueMeasurement of the thermal conductivity of n-pentane
    Y. Shi
    L. Sun
    J. E. S. Venart
    R. C. Prasad
    Journal of Thermal Analysis and Calorimetry, 2006, 86 : 585 - 590
  • [22] Correct Use of the Transient Hot-Wire Technique for Thermal Conductivity Measurements on Solids
    Antoniadis, Konstantinos D.
    Assael, Marc J.
    Wakeham, William A.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2024, 45 (12)
  • [23] Correct Use of the Transient Hot-Wire Technique for Thermal Conductivity Measurements on Fluids
    Marc J. Assael
    Konstantinos D. Antoniadis
    Danai Velliadou
    William A. Wakeham
    International Journal of Thermophysics, 2023, 44
  • [24] Correct Use of the Transient Hot-Wire Technique for Thermal Conductivity Measurements on Fluids
    Assael, Marc J.
    Antoniadis, Konstantinos D.
    Velliadou, Danai
    Wakeham, William A.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2023, 44 (06)
  • [25] A new transient hot-wire thermal conductivity apparatus and measurements of helium at temperatures from 20 K to 300 K
    Zhao, Xiufang
    Wang, Xian
    Dong, Xueqiang
    Wang, Yunxiao
    Zhao, Yanxing
    Sheng, Bowen
    Gong, Maoqiong
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2024, 192
  • [26] Absolute steady-state thermal conductivity measurements by use of a transient hot-wire system
    Roder, HM
    Perkins, RA
    Laesecke, A
    de Castro, CAN
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2000, 105 (02): : 221 - 253
  • [27] Thermal Conductivity Measurement of Semitransparent Solids by Hot-Wire Technique1
    F. Yu
    X. Zhang
    G. Gao
    International Journal of Thermophysics, 2000, 21 : 465 - 478
  • [28] Measurements of the thermal conductivity of molten lead using a new transient hot-wire sensor
    Bilek, Jaromir
    Atkinson, John
    Wakeham, William
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2007, 28 (02) : 496 - 505
  • [29] RADIATIVE HEAT-TRANSFER IN TRANSIENT HOT-WIRE MEASUREMENTS OF THERMAL-CONDUCTIVITY
    DECASTRO, CAN
    PERKINS, RA
    RODER, HM
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1991, 12 (06) : 985 - 997
  • [30] Measurements of the Thermal Conductivity of Molten Lead Using a New Transient Hot-Wire Sensor
    Jaromir Bilek
    John Atkinson
    William Wakeham
    International Journal of Thermophysics, 2007, 28 : 496 - 505