Effect of offset-frequency step size and interpolation methods on chemical exchange saturation transfer MRI computation in human brain

被引:5
作者
Debnath, Ayan [1 ,2 ]
Gupta, Rakesh Kumar [3 ]
Reddy, Ravinder [2 ]
Singh, Anup [1 ,4 ]
机构
[1] Indian Inst Technol Delhi, Ctr Biomed Engn, Room 299, New Delhi 110016, India
[2] Univ Penn, Dept Radiol, CMROI, Philadelphia, PA 19104 USA
[3] Fortis Mem Res Inst, Delhi, India
[4] All India Inst Med Sci, Delhi, India
关键词
APT; B-0 inhomogeneity correction; CEST; Cr‐ w; Glu‐ interpolation; MRI; offset‐ frequency step size;
D O I
10.1002/nbm.4468
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Chemical exchange saturation transfer (CEST) MRI is a non-invasive molecular imaging technique with potential applications in pre-clinical and clinical studies. Applications of amide proton transfer-weighted (APT-w), glutamate-weighted (Glu-w) and creatine-weighted (Cr-w) CEST, among others, have been reported. In general, CEST data are acquired at multiple offset-frequencies. In reported studies, different offset-frequency step sizes and interpolation methods have been used during B-0 inhomogeneity correction of data. The objective of the current study was to evaluate the effects of different step sizes and interpolation methods on CEST value computation. In the current study, simulation (Glu-w, Cr-w and APT-w) and experimental data from the brain were used. Experimental CEST data (Glu-w) were acquired from human volunteers at 7 T and brain tumor patients (APT-w) at 3 T. During B-0 inhomogeneity correction, different interpolation methods (polynomial [degree-1, 2 and 3], cubic-Hermite, cubic-spline and smoothing-spline) were compared. CEST values were computed using asymmetry analysis. The effects of different step sizes and interpolation methods were evaluated using coefficient of variation (CV), normalized mean square error (nMSE) and coefficient of correlation parameters. Additionally, an optimum interpolation method for APT-w values was selected based upon fitting accuracy, T-test, receiver operating characteristic analysis, and its diagnostic performance in differentiating low-grade and high-grade tumors. CV and nMSE increase with an increase in step size irrespective of the interpolation method (except for cubic-Hermite and cubic-spline). The nMSE of Cr-w and Glu-w CEST values were least for polynomial (degree-2 and 3). The quality of Glu-w CEST maps became coarse with the increase in step size. There was a significant difference (P < .05) between low-grade and high-grade tumors using polynomial interpolation (degree-1, 2 and 3); however, linear interpolation outperforms other methods for APT-w data, providing the highest sensitivity and specificity. In conclusion, depending upon the saturation parameters and field strength, optimization of step size and interpolation should be carried out for different CEST metabolites/molecules. Glu-w, Cr-w and APT-w CEST data should be acquired with a step size of between 0.2 and 0.3 ppm. For B-0 inhomogeneity correction, polynomial (degree-2) should be used for Glu-w and Cr-w CEST data at 7 T and linear interpolation should be used for APT-w data at 3 T for a limited frequency range.
引用
收藏
页数:14
相关论文
共 39 条
[1]   In vivo GluCEST MRI: Reproducibility, background contribution and source of glutamate changes in the MPTP model of Parkinson's disease [J].
Bagga, Puneet ;
Pickup, Stephen ;
Crescenzi, Rachelle ;
Martinez, Daniel ;
Borthakur, Arijitt ;
D'Aquilla, Kevin ;
Singh, Anup ;
Verma, Gaurav ;
Detre, John A. ;
Greenberg, Joel ;
Hariharan, Hari ;
Reddy, Ravinder .
SCIENTIFIC REPORTS, 2018, 8
[2]   Mapping the alterations in glutamate with GIuCEST MRI in a mouse model of dopamine deficiency [J].
Bagga, Puneet ;
Crescenzi, Rachelle ;
Krishnamoorthy, Guruprasad ;
Verma, Gaurav ;
Nanga, Ravi Prakash Reddy ;
Reddy, Damodar ;
Greenberg, Joel ;
Detre, John A. ;
Hariharan, Hari ;
Reddy, Ravinder .
JOURNAL OF NEUROCHEMISTRY, 2016, 139 (03) :432-439
[3]   Detection of early cartilage damage: feasibility and potential of gagCEST imaging at 7T [J].
Brinkhof, Sander ;
Nizak, Razmara ;
Khlebnikov, Vitaliy ;
Prompers, Jeanine J. ;
Klomp, Dennis W. J. ;
Saris, Daniel B. F. .
EUROPEAN RADIOLOGY, 2018, 28 (07) :2874-2881
[4]   CEST signal at 2ppm (CEST@2ppm) from Z-spectral fitting correlates with creatine distribution in brain tumor [J].
Cai, Kejia ;
Singh, Anup ;
Poptani, Harish ;
Li, Weiguo ;
Yang, Shaolin ;
Lu, Yang ;
Hariharan, Hari ;
Zhou, Xiaohong J. ;
Reddy, Ravinder .
NMR IN BIOMEDICINE, 2015, 28 (01) :1-8
[5]   Mapping glutamate in subcortical brain structures using high-resolution GluCEST MRI [J].
Cai, Kejia ;
Singh, Anup ;
Roalf, David R. ;
Nanga, Ravi Prakash Reddy ;
Haris, Mohammad ;
Hariharan, Hari ;
Gur, Ruben ;
Reddy, Ravinder .
NMR IN BIOMEDICINE, 2013, 26 (10) :1278-1284
[6]   Magnetic resonance imaging of glutamate [J].
Cai, Kejia ;
Haris, Mohammad ;
Singh, Anup ;
Kogan, Feliks ;
Greenberg, Joel H. ;
Hariharan, Hari ;
Detre, John A. ;
Reddy, Ravinder .
NATURE MEDICINE, 2012, 18 (02) :302-306
[7]  
Chen YZ., 2016, Radiol Infect Dis, V3, P92, DOI DOI 10.1016/J.JRID.2016.03.006
[8]   Glutamate imaging (GluCEST) lateralizes epileptic foci in nonlesional temporal lobe epilepsy [J].
Davis, Kathryn Adamiak ;
Nanga, Ravi Prakash Reddy ;
Das, Sandhitsu ;
Chen, Stephanie H. ;
Hadar, Peter N. ;
Pollard, John R. ;
Lucas, Timothy H. ;
Shinohara, Russell T. ;
Litt, Brian ;
Hariharan, Hari ;
Elliott, Mark A. ;
Detre, John A. ;
Reddy, Ravinder .
SCIENCE TRANSLATIONAL MEDICINE, 2015, 7 (309)
[9]   Effect of offset-frequency step size and interpolation methods on chemical exchange saturation transfer MRI computation in human brain [J].
Debnath, Ayan ;
Gupta, Rakesh Kumar ;
Reddy, Ravinder ;
Singh, Anup .
NMR IN BIOMEDICINE, 2021, 34 (04)
[10]   Evaluating the Role of Amide Proton Transfer (APT)-Weighted Contrast, Optimized for Normalization and Region of Interest Selection, in Differentiation of Neoplastic and Infective Mass Lesions on 3T MRI [J].
Debnath, Ayan ;
Gupta, Rakesh Kumar ;
Singh, Anup .
MOLECULAR IMAGING AND BIOLOGY, 2020, 22 (02) :384-396