An experimental study on the hydrodynamic performance of the water-wall system of a 600 MW supercritical CFB boiler

被引:22
|
作者
Chen, Ye [1 ]
Lu, Xiaofeng [1 ]
Zhang, Wenqing [2 ]
Wang, Quanhai [1 ]
Chen, Sida [1 ]
Fan, Xuchen [1 ]
Li, Jianbo [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
[2] Sichuan Baima CFB Demonstrat Power Plant Co Ltd, Neijiang 641005, Sichuan, Peoples R China
关键词
Mass flux; Metal temperature; Supercritical CFB boiler; Thermal-hydrodynamic performance; THERMAL-HYDRAULIC CALCULATION; HEAT-TRANSFER; FLUIDIZED-BED; FUZZY-LOGIC; TUBES; FLUX; RECIRCULATION; COMBUSTION; FURNACE;
D O I
10.1016/j.applthermaleng.2018.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The temperature distribution on the backside of the water-wall tubes in the first 600 MW CFB boiler operating at 60%, 80% and 100% of the boiler Maximum Continuous Rating (MCR) loads was experimentally determined and the thermal-hydrodynamic performance of water-wall system based on the mass and energy equations using the measured temperature was calculated. The results showed that the temperature of the water-wall tubes increased as the furnace height increased, showing a positive response characteristic in the water-wall system. However, the temperature of the water-wall tubes in the upper furnace was obviously declined at the places where the superheaters and cyclone separator inlet-channels were arranged. This suggests that the arrangement of the heat-transfer surfaces in the upper furnace was significantly influenced the temperature distribution of the water-wall tubes. Meanwhile, the calculated total pressure-drop and mass flux in the water-wall system increased as the boiler's load raised, showing an energy-efficiency for the vertical once-through boiler. In addition, the metal temperature was calculated to check the working condition of the water-wall tubes and the results showed the highest metal temperature of 426.3 degrees C of the water-wall tubes was found at the tip of the fin at 100% MCR. This temperature was far below the permissible temperature of the metal, implying that a safe working condition of the metal at three loads was guaranteed. Nonetheless, analysis into the heat-transfer characteristics of the water in the water-wall reflects that the water temperature in the water-wall at 80% MCR load was adjacent to the boundary of the large specific-heat region, implying that heat-transfer deterioration was more likely to occur at such condition. Therefore, the metal temperature of the water-wall tubes operating at 80% MCR load requires the most concern and monitor to avoid overheating of the water-wall tubes.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 35 条
  • [31] Experimental Study of Sawdust Syngas Gasification in Bench-Scale Gasifier and Three-Dimensional Numerical Analysis for Syngas Cocombustion in a 600 MW Coal-Fired Boiler Furnace
    Ren, Lachun
    Shang, Xinxin
    Xie, Jingjing
    Chen, Jiechao
    Gu, Yanan
    ACS OMEGA, 2024, 9 (50): : 49387 - 49396
  • [32] Industrial experimental study on combustion characteristics and NOx emission characteristics of a 600 MWe wall-fired boiler under ultra-low excess air coefficient conditions
    Ti, Shuguang
    Deng, Shanshan
    Yang, Zhi
    Zheng, Li
    Zhu, Youjian
    Gao, Ke
    Gao, Shang
    Yang, Jinhui
    Wang, Haopeng
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [33] Design and performance study of dry cooling system for 25 MW solar power plant operated with supercritical CO2 cycle
    Ehsan, M. Monjurul
    Wang, Xurong
    Guan, Zhigiang
    Klimenko, A. Y.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 132 : 398 - 410
  • [34] EXPERIMENTAL-STUDY ON HEAT REMOVAL CHARACTERISTICS FOR WATER WALL TYPE PASSIVE CONTAINMENT COOLING SYSTEM
    KATAOKA, Y
    FUJII, T
    MURASE, M
    TOMINAGA, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1994, 31 (10) : 1043 - 1052
  • [35] Effect of non-condensable gas on the performance of steam-water ejector in a trigeneration system for hydrogen production: An experimental and numerical study
    Zhang, Yi
    Qu, Xiaohang
    Zhang, Guanmin
    Leng, Xueli
    Tian, Maocheng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (39) : 20266 - 20281