Temperature rise during Er:YAG and Nd:YAP laser ablation of dentin

被引:65
作者
Armengol, V [1 ]
Jean, A [1 ]
Marion, D [1 ]
机构
[1] UFR Odontol, Dept Odontol Conservatrice Endodont, F-44042 Nantes, France
关键词
D O I
10.1097/00004770-200003000-00002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study compared temperature rises during cavity preparation with an Er:YAG laser, Nd: YAP laser, and a high-speed handpiece, Eighteen teeth were sectioned longitudinally and divided into six groups: group 1 was treated with a carbide bur on a high-speed dental handpiece; group 2 was treated with an Er:YAG laser with an energy of 140 mJ, a pulse repetition rate of 4 Hz; and group 3 was treated with an Nd:YAP laser with an energy of 240 mJ, a pulse repetition rate of 10 Hz, In these groups no water cooling was used. Groups 4 to 6 were treated in the same way, but with water spray. Temperature increases were measured at different dentin thicknesses by a microthermocouple attached to the inner side of the pulp chamber. Water cooling was essential to reduce temperature effects in all groups. Nd:YAP laser induced significantly higher temperature rises than Er:YAG or handpiece, Temperature response to the Er:YAG laser and the handpiece seemed to be similar.