Isolated electrodeless high-frequency quartz crystal microbalance for immunosensors

被引:69
|
作者
Ogi, Hirotsugu [1 ]
Motoshisa, Kazuma [1 ]
Matsumoto, Takashi [1 ]
Hatanaka, Kenichi [1 ]
Hirao, Masahiko [1 ]
机构
[1] Osaka Univ, Grad Sch Engn Sci, Osaka 5608531, Japan
关键词
D O I
10.1021/ac061004a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a contactless technique to measure shear bulk wave resonance frequencies of an isolated quartz crystal in a flow cell. The line antenna placed outside the cell generates and detects the resonance frequencies in a wireless-electrodeless manner. It is revealed that this mechanism relies on the quasistatic electric field. A 0.3-mm-thick AT-cut quartz was used, and its overtone resonance frequencies up to 80 MHz were measured in liquids. Exact vibrational analysis was carried out for a triple-layered resonator system consisting of the adsorbed material layer, the electrode film, and the quartz plate. It predicts higher frequency sensitivity to the adsorbed material at higher modes when the electrode layer is removed. The 13th overtone (72-MHz resonance frequency) was used to detect human immunoglobulin G with concentrations between 0.1 and 20 mu g/mL captured by protein A immobilized on one side of the crystal. The real-time measurement of the frequency response yielded the equilibrium constant K-A = 5.21 x 10(7) M-1.
引用
收藏
页码:6903 / 6909
页数:7
相关论文
共 50 条
  • [1] High-frequency wireless and electrodeless quartz crystal microbalance developed as immunosensor
    Ogi, Hirotsugu
    Motohisa, Kazuma
    Hatanaka, Kenichi
    Ohmori, Toshinobu
    Hirao, Masahiko
    Nishiyama, Masayoshi
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (7B): : 4693 - 4697
  • [2] High-Frequency Electrodeless Quartz Crystal Microbalance Chip with a Bare Quartz Resonator Encapsulated in a Silicon Microchannel
    Kato, Fumihito
    Ogi, Hirotsugu
    Yanagida, Taiji
    Nishikawa, Shintaro
    Nishiyama, Masayoshi
    Hirao, Masahiko
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (07)
  • [3] Using high-frequency quartz crystal microbalance
    Kurosawa, S
    Han, DS
    Park, JW
    Aizawa, H
    Yoshimoto, M
    Nakamura, C
    Miyake, J
    Chang, SM
    PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION, 2001, : 462 - 464
  • [4] Immunosensors using a quartz crystal microbalance
    Kurosawa, S
    Aizawa, H
    Tozuka, M
    Nakamura, M
    Park, JW
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) : 1882 - 1887
  • [5] Quartz crystal microbalance immunosensors for environmental monitoring
    Kurosawa, Shigeru
    Park, Jong-Won
    Aizawa, Hidenobu
    Wakida, Shin-Ichi
    Tao, Hiroaki
    Ishihara, Kazuhiko
    BIOSENSORS & BIOELECTRONICS, 2006, 22 (04): : 473 - 481
  • [6] Miniaturized High-Frequency Humidity Sensor Based on Quartz Crystal Microbalance
    Feng, Lihui
    Shi, Zhongyu
    Yang, Jueying
    Chen, Yu
    Lu, Jihua
    Guo, Junqiang
    Tang, Yi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [7] Miniaturized High-Frequency Humidity Sensor Based on Quartz Crystal Microbalance
    Feng, Lihui
    Shi, Zhongyu
    Yang, Jueying
    Chen, Yu
    Lu, Jihua
    Guo, Junqiang
    Tang, Yi
    IEEE Transactions on Instrumentation and Measurement, 2022, 71
  • [8] High-Frequency Rheological Characterization of Homogeneous Polymer Films with the Quartz Crystal Microbalance
    DeNolf, Garret C.
    Sturdy, Lauren F.
    Shull, Kenneth R.
    LANGMUIR, 2014, 30 (32) : 9731 - 9740
  • [9] A combined nanoplasmonic and electrodeless quartz crystal microbalance setup
    Larsson, Elin M.
    Edvardsson, Malin E. M.
    Langhammer, Christoph
    Zoric, Igor
    Kasemo, Bengt
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (12):
  • [10] High-resolution gas/odor sensors using high-frequency quartz crystal microbalance
    Benemérita Universidad Autónoma de Puebla, Facultad de Ciencias Físico Matemáticas, Av. San Claudio y 18 Sur, Col. San Manuel , Puebla, Pue. CP. 72570, Mexico
    不详
    不详
    Muñoz-Aguirre, S. (smunoz@fcfm.buap.mx), 1600, M Y U Scientific Publishing Division (26):