Characterization of aqueous two phase systems by combining lab-on-a-chip technology with robotic liquid handling stations

被引:12
作者
Amrhein, Sven [1 ]
Schwab, Marie-Luise [1 ]
Hoffmann, Marc [1 ]
Hubbuch, Juergen [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Proc Engn Life Sci, Sect Biomol Separat Engn 4, D-76021 Karlsruhe, Germany
关键词
Aqueous two phase system; Tie line; Density; High throughput; Phase separation; Lab-on-a-chip; Microfluidics; LATEST DEVELOPMENTS; QUANTIFICATION; EQUILIBRIUM; POLYMER;
D O I
10.1016/j.chroma.2014.09.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last decade, the use of design of experiment approaches in combination with fully automated high throughput (HTP) compatible screenings supported by robotic liquid handling stations (LHS), adequate fast analytics and data processing has been developed in the biopharmaceutical industry into a strategy of high throughput process development (HTPD) resulting in lower experimental effort, sample reduction and an overall higher degree of process optimization. Apart from HTP technologies, lab-on-a-chip technology has experienced an enormous growth in the last years and allows further reduction of sample consumption. A combination of LHS and lab-on-a-chip technology is highly desirable and realized in the present work to characterize aqueous two phase systems with respect to tie lines. In particular, a new high throughput compatible approach for the characterization of aqueous two phase systems regarding tie lines by exploiting differences in phase densities is presented. Densities were measured by a standalone micro fluidic liquid density sensor, which was integrated into a liquid handling station by means of a developed generic Tip2World interface. This combination of liquid handling stations and lab-on-a-chip technology enables fast, fully automated, and highly accurate density measurements. The presented approach was used to determine the phase diagram of ATPSs composed of potassium phosphate (pH 7) and polyethylene glycol (PEG) with a molecular weight of 300, 400, 600 and 1000 Da respectively in the presence and in the absence of 3% (w/w) sodium chloride. Considering the whole ATPS characterization process, two complete ATPSs could be characterized within 24 h, including four runs per ATPS for binodal curve determination (less than 45 min/run), and tie line determination (less than 45 min/run for ATPS preparation and 8 h for density determination), which can be performed fully automated over night without requiring man power. The presented methodology provides a cost, time and material effective approach for characterization of ATPS phase diagram on base on highly accurate and comprehensive data. By this means the derived data opens the door for a more detailed description of ATPS towards generating mechanistic based models, since molecular approaches such as MD simulations or molecular descriptions along the line of QSAR heavily rely on accurate and comprehensive data. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 50 条
  • [41] Extraction and purification of wheat-esterase using aqueous two-phase systems of ionic liquid and salt
    Bin Jiang
    Zhibiao Feng
    Chunhong Liu
    Yingcao Xu
    Dongmei Li
    Guo Ji
    Journal of Food Science and Technology, 2015, 52 : 2878 - 2885
  • [42] High throughput screening techniques in downstream processing: Preparation, characterization and optimization of aqueous two-phase systems
    Bensch, Matthias
    Selbach, Bjorn
    Hubbuch, Juergen
    CHEMICAL ENGINEERING SCIENCE, 2007, 62 (07) : 2011 - 2021
  • [43] Liquid-liquid equilibrium of aqueous two-phase systems containing thermo-sensitive copolymer L31 and salts
    Wang, Yun
    Mao, Yanli
    Chen, Chen
    Han, Juan
    Wang, Lei
    Hu, Xiaowei
    Chen, Tong
    Ni, Liang
    Hu, Yutao
    FLUID PHASE EQUILIBRIA, 2015, 387 : 12 - 17
  • [44] Liquid-liquid equilibria of aqueous two-phase systems composed of TritonX-100 and sodium citrate or magnesium sulfate salts
    Salabat, Alireza
    Moghadam, Somayeh Tiani
    Far, Mina Rahmati
    CALPHAD-COMPUTER COUPLING OF PHASE DIAGRAMS AND THERMOCHEMISTRY, 2010, 34 (01): : 81 - 83
  • [45] Ionic-Liquid-Based Aqueous Two-Phase Systems Induced by Intra- and Intermolecular Hydrogen Bonds
    Xu, Wenzhuo
    Gao, Xinpei
    Zheng, Liqiang
    Lu, Fei
    MOLECULES, 2022, 27 (16):
  • [46] The impact of self-aggregation on the extraction of biomolecules in ionic-liquid-based aqueous two-phase systems
    Passos, Helena
    Trindade, Margarida P.
    Vaz, Tatiana S. M.
    da Costa, Luiz P.
    Freire, Mara G.
    Coutinho, Joao A. P.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 108 : 174 - 180
  • [47] Modification of NRTL-NRF model for computation of liquid-liquid equilibria in aqueous two-phase polymer-salt systems
    Haghtalab, Ali
    Joda, Marzieh
    FLUID PHASE EQUILIBRIA, 2009, 278 (1-2) : 20 - 26
  • [48] Determination and correlation of phase equilibria of chiral magnetic ionic liquid aqueous two-phase systems with different inorganic salts at 298.15 K
    Yao, Tian
    Li, Hongmei
    Yang, Jiawen
    Shi, Xiaodong
    Yan, Huiling
    Peng, Lianxin
    JOURNAL OF MOLECULAR LIQUIDS, 2022, 345
  • [49] Extraction of 1,3-propanediol from aqueous solutions using different ionic liquid-based aqueous two-phase systems
    Mueller, Anja
    Gorak, Andrzej
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 97 : 130 - 136
  • [50] A high efficiency method combining metal chelate ionic liquid-based aqueous two-phase flotation with two-step precipitation process for bromelain purification
    Han, Juan
    Cai, Yunfeng
    Wang, Lei
    Mao, Yanli
    Ni, Liang
    Wang, Yun
    FOOD CHEMISTRY, 2020, 309