Characterization of aqueous two phase systems by combining lab-on-a-chip technology with robotic liquid handling stations

被引:12
作者
Amrhein, Sven [1 ]
Schwab, Marie-Luise [1 ]
Hoffmann, Marc [1 ]
Hubbuch, Juergen [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Proc Engn Life Sci, Sect Biomol Separat Engn 4, D-76021 Karlsruhe, Germany
关键词
Aqueous two phase system; Tie line; Density; High throughput; Phase separation; Lab-on-a-chip; Microfluidics; LATEST DEVELOPMENTS; QUANTIFICATION; EQUILIBRIUM; POLYMER;
D O I
10.1016/j.chroma.2014.09.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last decade, the use of design of experiment approaches in combination with fully automated high throughput (HTP) compatible screenings supported by robotic liquid handling stations (LHS), adequate fast analytics and data processing has been developed in the biopharmaceutical industry into a strategy of high throughput process development (HTPD) resulting in lower experimental effort, sample reduction and an overall higher degree of process optimization. Apart from HTP technologies, lab-on-a-chip technology has experienced an enormous growth in the last years and allows further reduction of sample consumption. A combination of LHS and lab-on-a-chip technology is highly desirable and realized in the present work to characterize aqueous two phase systems with respect to tie lines. In particular, a new high throughput compatible approach for the characterization of aqueous two phase systems regarding tie lines by exploiting differences in phase densities is presented. Densities were measured by a standalone micro fluidic liquid density sensor, which was integrated into a liquid handling station by means of a developed generic Tip2World interface. This combination of liquid handling stations and lab-on-a-chip technology enables fast, fully automated, and highly accurate density measurements. The presented approach was used to determine the phase diagram of ATPSs composed of potassium phosphate (pH 7) and polyethylene glycol (PEG) with a molecular weight of 300, 400, 600 and 1000 Da respectively in the presence and in the absence of 3% (w/w) sodium chloride. Considering the whole ATPS characterization process, two complete ATPSs could be characterized within 24 h, including four runs per ATPS for binodal curve determination (less than 45 min/run), and tie line determination (less than 45 min/run for ATPS preparation and 8 h for density determination), which can be performed fully automated over night without requiring man power. The presented methodology provides a cost, time and material effective approach for characterization of ATPS phase diagram on base on highly accurate and comprehensive data. By this means the derived data opens the door for a more detailed description of ATPS towards generating mechanistic based models, since molecular approaches such as MD simulations or molecular descriptions along the line of QSAR heavily rely on accurate and comprehensive data. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 50 条
  • [1] Design, fabrication and characterization of drug delivery systems based on lab-on-a-chip technology
    Nam-Trung Nguyen
    Shaegh, Seyed Ali Mousavi
    Kashaninejad, Navid
    Dinh-Tuan Phan
    ADVANCED DRUG DELIVERY REVIEWS, 2013, 65 (11-12) : 1403 - 1419
  • [2] A disposable lab-on-a-chip platform with embedded fluid actuators for active nanoliter liquid handling
    Björn Samel
    Volker Nock
    Aman Russom
    Patrick Griss
    Göran Stemme
    Biomedical Microdevices, 2007, 9 : 61 - 67
  • [3] A disposable lab-on-a-chip platform with embedded fluid actuators for active nanoliter liquid handling
    Samel, Bjorn
    Nock, Volker
    Russom, Aman
    Griss, Patrick
    Stemme, Goran
    BIOMEDICAL MICRODEVICES, 2007, 9 (01) : 61 - 67
  • [4] Liquid reagent storage in self-pumping Lab-on-a-Chip systems for quick assay and biosensor integration
    Nestler, Joerg
    Haber, Nora
    Stiehl, Cornelia
    Otto, Thomas
    Gessner, Thomas
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [5] A Rapid Method for Estimation of Cariogenic Bacteria Based on a Stationary Liquid Phase Lab-on-a-chip
    Kim, Hee-Jung
    Choi, Suk-Jung
    BIOCHIP JOURNAL, 2018, 12 (01) : 52 - 58
  • [6] A Rapid Method for Estimation of Cariogenic Bacteria Based on a Stationary Liquid Phase Lab-on-a-chip
    Hee-Jung Kim
    Suk-Jung Choi
    BioChip Journal, 2018, 12 : 52 - 58
  • [7] Immunoassay of paralytic shellfish toxins by moving magnetic particles in a stationary liquid-phase lab-on-a-chip
    Kim, Myoung-Ho
    Choi, Suk-Jung
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 136 - 140
  • [8] Development of an Improved Stationary Liquid-phase Lab-on-a-chip for the Field Monitoring of Paralytic Shellfish Toxins
    Yu, Eunkyeong
    Choi, Suk-Jung
    BIOCHIP JOURNAL, 2017, 11 (01) : 30 - 38
  • [9] Development of an improved stationary liquid-phase lab-on-a-chip for the field monitoring of paralytic shellfish toxins
    Eunkyeong Yu
    Suk-Jung Choi
    BioChip Journal, 2017, 11 : 30 - 38
  • [10] Implementation of droplet-membrane-droplet liquid-phase microextraction under stagnant conditions for lab-on-a-chip applications
    Sikanen, Tiina
    Pedersen-Bjergaard, Stig
    Jensen, Henrik
    Kostiainen, Risto
    Rasmussen, Knut Einar
    Kotiaho, Tapio
    ANALYTICA CHIMICA ACTA, 2010, 658 (02) : 133 - 140