Evaluating Corneal Fluorescein Staining Using a Novel Automated Method

被引:42
作者
Amparo, Francisco [1 ]
Wang, Haobing [2 ]
Yin, Jia [1 ]
Marmalidou, Anna [1 ]
Dana, Reza [1 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear Infirm, Boston, MA 02115 USA
[2] Harvard Med Sch, Peabody Lab, Massachusetts Eye & Ear Infirm, Boston, MA 02115 USA
关键词
corneal fluorescein staining; ocular surface; dry eye; CFS; automated CFS; CFSi;
D O I
10.1167/iovs.17-21831
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate interobserver concordance in measured corneal fluorescein staining (CFS) using the National Eye Institute/Industry (NEI) grading scale and the Corneal Fluorescein Staining Index (CFSi), a computer-assisted, objective, centesimal scoring system. METHODS. We conducted a study to evaluate CFS in clinical photographs of patients with corneal epitheliopathy. One group of clinicians graded CFS in the images using the NEI while a second group applied the CFSi. We evaluated the level of interobserver agreement and differences among CFS scores with each method, level of correlation between the two methods, and distribution of cases based on the CFS severity assigned by each method. RESULTS. The level of interobserver agreement was 0.65 (P < 0.001) with the NEI, and 0.99 (P < 0.001) with the CFSi. There were statistically significant differences among clinicians' measurements obtained with the NEI (P < 0.001), but not with the CFSi (P = 0.78). There was a statistically significant correlation between the CFS scores obtained with the two methods (R = 0.72; P < 0.001). The NEI scale allocated the majority of cases (65%) within the higher quartile in the scale's severity (12-15/15). In contrast, the CFSi allocated the majority of cases (61%) within the lower quartile in the scale's severity (0-25/100). CONCLUSIONS. The CFSi is easy to implement, provides higher interobserver consistency, and due to its continuous score can discriminate smaller differences in CFS. Reproducibility of the computer-based system is higher and, interestingly, the system allocates cases of epitheliopathy in different severity categories than clinicians do. The CFSi can be an alternative for objective CFS evaluation in the clinic and in clinical trials.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 15 条
[1]  
Agoston MaxK., 2005, Computer Graphics and Geometric Modeling: Implementation and Algorithms, P300
[2]   Clinical staining of the ocular surface: Mechanisms and interpretations [J].
Bron, A. J. ;
Argueeso, P. ;
Irkec, M. ;
Bright, F. V. .
PROGRESS IN RETINAL AND EYE RESEARCH, 2015, 44 :36-61
[3]   Grading of corneal and conjunctival staining in the context of other dry eye tests [J].
Bron, AJ ;
Evans, VE ;
Smith, JA .
CORNEA, 2003, 22 (07) :640-650
[4]  
Bron AJ, 2007, OCUL SURF, V5, P108
[5]   Objective Assessment of Corneal Staining Using Digital Image Analysis [J].
Chun, Yeoun Sook ;
Yoon, Woong Bae ;
Kim, Kwang Gi ;
Park, In Ki .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) :7896-7903
[6]  
Cicchetti DV., 1994, PSYCHOL ASSESSMENTS, V6, P284, DOI [10.1037/1040-3590.6.4.284, DOI 10.1037/1040-3590.6.4.284]
[7]   A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J].
Koo, Terry K. ;
Li, Mae Y. .
JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) :155-163
[8]  
Lemp Michael A., 1995, CLAO Journal, V21, P221
[9]  
Lemp MA, 2007, OCUL SURF, V5, P75
[10]  
MAURICE D. M., 1967, INVEST OPHTHALMOL, V6, P464