The Impact of Intraaortic Balloon Counterpulsation on Bypass Graft Flow in Patients with Peripheral ECMO

被引:41
作者
Madershahian, Navid [1 ]
Liakopoulos, Oliver J. [1 ]
Wippermann, Jens [1 ]
Salehi-Gilani, Shahriar [1 ]
Wittwer, Thorsten [1 ]
Choi, Yeong-Hoon [1 ]
Naraghi, Hamid [1 ]
Wahlers, Thorsten [1 ]
机构
[1] Univ Cologne, Ctr Heart, Dept Cardiothorac Surg, D-50924 Cologne, Germany
关键词
EXTRACORPOREAL MEMBRANE-OXYGENATION; NON-PULSATILE PERFUSION; CARDIOPULMONARY BYPASS; CARDIOPLEGIC ARREST; CARDIOGENIC-SHOCK; RANDOMIZED-TRIAL; PUMP; REPERFUSION; RECOVERY;
D O I
10.1111/j.1540-8191.2009.00807.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Numerous reports have been performed to investigate the hemodynamic effects of intraaortic balloon pumping (IABP) and nonpulsatile circulatory extracorporeal membrane oxygenation (ECMO), but studies on its impact on coronary artery bypass graft flow during concomitant use of IABP and ECMO are lacking. The aim of this study was to assess the impact of additional IABP support on the degree of blood flow increase in bypass grafts in high-risk patients with nonpulsatile femoral venoarterial ECMO. Methods: In six emergency coronary artery bypass graft patients (mean age = 66.3 +/- 2.1 years, gender = five males and one female, ejection fraction = 25.0 +/- 3.0%) requiring mechanical circulatory support with ECMO hemodynamic parameters and bypass graft flows were measured with and without IABP counterpulsation. A transit time flowmeter was used for intraoperative graft flow and pulsatility index (PI) measurements. Patients provided their control values. Results: The average value of the mean arterial pressure recorded prior to IABP was 63.6 + 2.9 mmHg and during IABP support 67.8 + 2.9 mmHg (p < 0.0001). IABP augmented the mean bypass graft flow from 46.8 +/- 9.6 mL/min to 56.4 +/- 12.1 mL/min (p < 0.005), resulting in a 17% increase. The difference in the PI was not statistically significant (2.6 +/- 0.2 with IABP, 2.6 +/- 0.3 without IABP). Conclusions: We conclude that IABP-induced pulsatility significantly improves coronary bypass graft flows during nonpulsatile peripheral ECMO. (J Card Surg 2009;24:265-268).
引用
收藏
页码:265 / 268
页数:4
相关论文
共 24 条
  • [1] AKYUREKLI Y, 1980, CAN J SURG, V23, P122
  • [2] BELLOTTO F, 1992, J THORAC CARDIOV SUR, V104, P561
  • [3] PERCUTANEOUS INTRA-AORTIC BALLOON PUMPING - INITIAL CLINICAL-EXPERIENCE
    BREGMAN, D
    CASARELLA, WJ
    [J]. ANNALS OF THORACIC SURGERY, 1980, 29 (02) : 153 - 155
  • [4] PLASMA-RENIN ACTIVITY AND URINE BETA-2-MICROGLOBULIN DURING AND AFTER CARDIOPULMONARY BYPASS - PULSATILE VS NON-PULSATILE PERFUSION
    CANIVET, JL
    LARBUISSON, R
    DAMAS, P
    BLAFFART, F
    FAYMONVILLE, M
    LIMET, R
    LAMY, M
    [J]. EUROPEAN HEART JOURNAL, 1990, 11 (12) : 1079 - 1082
  • [5] A miniature implantable axial flow ventricular assist device
    DeBakey, ME
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (02) : 637 - 640
  • [6] Finlayson D C, 1987, J Cardiothorac Anesth, V1, P169, DOI 10.1016/0888-6296(87)90013-5
  • [7] EFFECT OF CARDIOPULMONARY BYPASS ON GASTROINTESTINAL PERFUSION AND FUNCTION
    GAER, JAR
    SHAW, ADS
    WILD, R
    SWIFT, RI
    MUNSCH, CM
    SMITH, PLC
    TAYLOR, KM
    [J]. ANNALS OF THORACIC SURGERY, 1994, 57 (02) : 371 - 375
  • [8] PERCUTANEOUS INTRA-AORTIC BALLOON COUNTERPULSATION - CLINICAL EFFECTIVENESS AND HAZARDS
    HAUSER, AM
    GORDON, S
    GANGADHARAN, V
    RAMOS, RG
    WESTVEER, DC
    GARG, AK
    TIMMIS, GC
    [J]. CHEST, 1982, 82 (04) : 422 - 425
  • [9] Kaul TK, 1996, J THORAC CARDIOV SUR, V111, P1001, DOI 10.1016/S0022-5223(96)70377-X
  • [10] ENHANCED RECOVERY OF ISCHEMIC MYOCARDIUM BY COMBINING PERCUTANEOUS BYPASS WITH INTRAAORTIC BALLOON PUMP SUPPORT
    LAZAR, HL
    TREANOR, P
    YANG, XM
    RIVERS, S
    BERNARD, S
    SHEMIN, RJ
    [J]. ANNALS OF THORACIC SURGERY, 1994, 57 (03) : 663 - 667