Polyamidoamine dendrimers as sweeping agent and stationary phase for rapid and sensitive open-tubular capillary electrophoretic determination of heavy metal ions

被引:16
作者
Ge, Ying [1 ]
Guo, Yujun [1 ]
Qin, Weidong [1 ]
机构
[1] Beijing Normal Univ, Coll Chem, Beijing 100875, Peoples R China
基金
中国国家自然科学基金;
关键词
Polyamidoamine dendrimer; Dual sweeping; Open-tubular capillary; electrochromatography; Heavy metal; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; CONTACTLESS CONDUCTIVITY DETECTION; POLY(AMIDOAMINE) DENDRIMERS; PSEUDOSTATIONARY PHASE; SEPARATION; PRECONCENTRATION; COMPLEXATION; 4-(2-PYRIDYLAZO)RESORCINOL; STACKING; MERCURY;
D O I
10.1016/j.talanta.2013.12.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polyamidoamine (PAMAM) dendrimer generation 2.5 was synthesized and evaluated as sweeping agent for in-column enrichment and as stationary phase for capillary electrochromatographic separation of heavy metal ions, viz., Pb(II), Cu(II), Hg(II), Zn(II) and Co(II), in a running buffer containing 4-(2-pyridylazo)resorcinol (PAR) as a chromogenic reagent. During experiment, a plug of aqueous PAMAM generation 2.5 solution was first introduced to the capillary, followed by electrokinetic injection of the heavy metal ions under a positive voltage. In this step, PAMAM acted as a sweeping agent, stacking the metal ions on the analyte/PAMAM boundary by forming metal ion-PAMAM complexes. The second preconcentration process occurred when PAR, a stronger ligand, moving toward the injection end under the electric field, reached and re-swept the metal ion-PAMAM zone, forming metal ion-PAR complexes. During separation, the neutral PAMAM moved toward the detector with the electroosmotic flow, dynamically coating the capillary wall, forming stationary phases that affected the separation of the metal ions. Due to the function of PAMAM, the detection sensitivity and resolution of the heavy metal ions improved significantly. Under the optimum conditions, the detection limits were 0.299, 0.184, 0.774, 0.182 and 0.047 mu g/L for Pb(II), Cu(II), Hg(II), Zn(II) and Co(II), respectively. The method was successfully applied to the determination of heavy metals in snow, tap and rain water samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 36 条
  • [31] Incorporation of polyamidoamine sweeping and electrokinetic supercharging for in-line DNA fragment preconcentration
    Tian, Jing
    Qiao, Jinping
    Gao, Jingjie
    Qin, Weidong
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1280 : 112 - 116
  • [32] Coprecipitation with Cu(II)-4-(2-Pyridylazo)-resorcinol for Separation and Preconcentration of Fe(III) and Ni(II) in Water and Food Samples
    Tokalioglu, Serife
    Dasdelen, Osman
    [J]. CLEAN-SOIL AIR WATER, 2011, 39 (03) : 296 - 300
  • [33] A NEW CLASS OF POLYMERS - STARBURST-DENDRITIC MACROMOLECULES
    TOMALIA, DA
    BAKER, H
    DEWALD, J
    HALL, M
    KALLOS, G
    MARTIN, S
    ROECK, J
    RYDER, J
    SMITH, P
    [J]. POLYMER JOURNAL, 1985, 17 (01) : 117 - 132
  • [34] Dual-cloud point extraction as a preconcentration and clean-up technique for capillary electrophoresis speciation analysis of mercury
    Yin, Xue-Bo
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 437 - 443
  • [35] Combination of Acid-Free Open-Vessel Wet Digestion and Poly(amidoamine) Dendrimer-Enhanced Capillary Electrophoresis for Determination of Metal Ions in Wines
    Zhang, Chenling
    Zhang, Yuan
    Qin, Weidong
    [J]. FOOD ANALYTICAL METHODS, 2014, 7 (01) : 165 - 171
  • [36] A novel isotachophoresis of cobalt and copper complexes by metal ion substitution reaction in a continuous moving chelation boundary
    Zhang, Wei
    Chen, Jian-Feng
    Fan, Liu-Yin
    Cao, Cheng-Xi
    Ren, Ji-Cun
    Li, Si
    Shao, Jing
    [J]. ANALYST, 2010, 135 (01) : 140 - 148