Reliability and Validity of the Functional Gait Assessment (German Version) in Subacute Stroke Patients

被引:53
作者
Thieme, Holm [1 ]
Ritschel, Claudia [2 ]
Zange, Christian [2 ]
机构
[1] Klin Bavaria Kreischa, Sch Physiotherapy Occupat Therapy & Speech & Lang, Sachsen, Germany
[2] Klin Bavaria Kreischa, Dept Neurol Rehabil, Sachsen, Germany
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2009年 / 90卷 / 09期
关键词
Balance; Gait; Outcome assessment; Rehabilitation; Reliability and validity; Stroke; MINI-MENTAL-STATE; PSYCHOMETRIC PROPERTIES; VESTIBULAR DYSFUNCTION; BARTHEL INDEX; BALANCE SCALE; HEALTH; REHABILITATION; RESPONSIVENESS; INDIVIDUALS; PERFORMANCE;
D O I
10.1016/j.apmr.2009.03.007
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate validity and reliability of the Functional Gait Assessment (FGA) (German version) as a measure for balance abilities during walking in subacute stroke patients. Design: Cohort study. Setting: Inpatient rehabilitation center. Participants: Ambulatory subjects (N=28) at a maximum of 6 months after stroke participated in this study. One direct observer and 2 video observers rated the FGA. Interventions: Not applicable. Main Outcome Measures: Performance of the FGA was video recorded and directly rated. For testing concurrent validity of the FGA, subjects also completed testing in the Berg Balance Scale, fast walking speed, the Functional Ambulatory Category, the Rivermead Mobility Index, and the Barthel Index. Intrarater reliability, interrater reliability, and concurrent validity of the FGA were analyzed. Results: Intrarater (intraclass correlation coefficient=.97) and interrater reliability (intraclass correlation coefficient =.94) were almost perfect for total scores. Reliability of single items varied between substantial and almost perfect values. Analysis revealed significant correlations between the FGA and other measures of gait and balance functions between Spearman rho values of .71 and .93. The FGA differs significantly between levels of gait ability (Functional Ambulatory Category) (P <=.01). Conclusions: Almost perfect intrarater and interrater reliability for total FGA scores and good concurrent validity were shown in this study. Therefore, the FGA (German version) can be used as a reliable and valid tool to assess functional gait performance of patients in subacute stages after stroke.
引用
收藏
页码:1565 / 1570
页数:6
相关论文
共 36 条
  • [1] BERG K, 1995, SCAND J REHABIL MED, V27, P27
  • [2] BERG KO, 1992, CAN J PUBLIC HEALTH, V83, pS7
  • [3] Norms for the mini-mental state examination - Adjustment of the cut-off point in population-based studies (evidences from the Bambui health aging study)
    Castro-Costa, Erico
    Fuzikawa, Cintia
    Uchoa, Elizabeth
    Araujo Firmo, Joselio Oliveira
    Lima-Costa, Maria Fernando
    [J]. ARQUIVOS DE NEURO-PSIQUIATRIA, 2008, 66 (3A) : 524 - 528
  • [4] Collen F M, 1991, Int Disabil Stud, V13, P50
  • [5] Recovery of standing balance in postacute stroke patients: A rehabilitation cohort study
    de Haart, M
    Geurts, AC
    Huidekoper, SC
    Fasotti, L
    van Limbeek, J
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (06): : 886 - 895
  • [6] MINI-MENTAL STATE - PRACTICAL METHOD FOR GRADING COGNITIVE STATE OF PATIENTS FOR CLINICIAN
    FOLSTEIN, MF
    FOLSTEIN, SE
    MCHUGH, PR
    [J]. JOURNAL OF PSYCHIATRIC RESEARCH, 1975, 12 (03) : 189 - 198
  • [7] Reliability of gait speed measured by a timed walking test in patients one year after stroke
    Green, J
    Forster, A
    Young, J
    [J]. CLINICAL REHABILITATION, 2002, 16 (03) : 306 - 314
  • [8] GAIT ASSESSMENT FOR NEUROLOGICALLY IMPAIRED PATIENTS - STANDARDS FOR OUTCOME ASSESSMENT
    HOLDEN, MK
    GILL, KM
    MAGLIOZZI, MR
    [J]. PHYSICAL THERAPY, 1986, 66 (10): : 1530 - 1539
  • [9] CLINICAL GAIT ASSESSMENT IN THE NEUROLOGICALLY IMPAIRED - RELIABILITY AND MEANINGFULNESS
    HOLDEN, MK
    GILL, KM
    MAGLIOZZI, MR
    NATHAN, J
    PIEHLBAKER, L
    [J]. PHYSICAL THERAPY, 1984, 64 (01): : 35 - 40
  • [10] Hsieh CL, 2000, SCAND J REHABIL MED, V32, P140