Development of membrane extraction with a sorbent interface-micro gas chromatography system for field analysis

被引:52
作者
Segal, A
Górecki, T
Mussche, P
Lips, J
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Chrompack, NL-4330 EA Middelburg, Netherlands
关键词
membrane extraction with a sorbent interface; membranes; extraction methods; benzene; toluene; ethylbenzene; xylenes;
D O I
10.1016/S0021-9673(99)01318-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The commercially available portable gas chromatographs have a rather limited scope of applications, typically allowing analysis of gaseous samples only, and having relatively poor sensitivity. Combination of those instruments with modern sampling/sample preparation techniques can remedy these problems. A Chrompack micro-CC system equipped with a thermal conductivity detector has been coupled to membrane extraction with a sorbent interface (MESI). The sorbent trap has replaced the GC injector. The design of the trap was also modified in order to enhance the preconcentration of analytes. The use of a thin flat sheet membrane reduces the response time, and decreases the memory effect of the system. Rapid separation times were achieved, and the sensitivity was significantly improved. MESI enables semi-continuous monitoring of both gaseous and aqueous samples, owing to the selectivity of the membrane material. The system does not use moving parts, therefore being reliable. The sensitivity of the micro-CC system was increased by a factor of more than 100 by the addition of the MESI system, even with a preconcentration time as short as 1 min. Chloroform, having a concentration lower than 1 ppb, was detected in tap water. A cup system was used to allow headspace sampling of volatile organic compounds from aqueous matrices, keeping the membrane away from interfering species that could be present in water, and improving the mass transfer. A linear calibration line was obtained, and the estimated limit of detection was 60 ppt. This represents a great improvement for the sensitivity of the micro-CC system. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:13 / 27
页数:15
相关论文
共 14 条
[1]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[2]  
ARTHUR CL, 1993, J MICROCOLUMN SEP, V5, P1
[3]  
ARTHUR CL, 1992, J ENV SCI TECHNOL, V26, P979
[4]  
ARTHUR CL, 1990, ANAL CHEM, V62, P45
[5]  
BOYDBOLAND AA, 1994, ENVIRON SCI TECHNOL, V28, P569
[6]   SAMPLE INTRODUCTION APPROACHES FOR SOLID-PHASE MICROEXTRACTION RAPID GC [J].
GORECKI, T ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3265-3274
[7]  
GORECKI T, 1999, LC GC EUR, V12, P123
[8]   DYNAMICS OF ORGANIC-COMPOUND EXTRACTION FROM WATER USING LIQUID-COATED FUSED-SILICA FIBERS [J].
LOUCH, D ;
MOTLAGH, S ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1187-1199
[9]   DETECTION OF SUBSTITUTED BENZENES IN WATER AT THE PG/ML LEVEL USING SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION TRAP MASS-SPECTROMETRY [J].
POTTER, DW ;
PAWLISZYN, J .
JOURNAL OF CHROMATOGRAPHY, 1992, 625 (02) :247-255
[10]  
VANES A, 1990, THESIS EINDHOVEN U T