Comparison of Goldmann Applanation Tonometry and Dynamic Contour Tonometry in the Measurement of Intraocular Pressure in Eyes with Different Corneal Thicknesses

被引:9
作者
Roszkowska, A. M. [1 ]
De Grazia, L. [1 ]
Cirone, M. [1 ]
Ferreri, G. [1 ]
机构
[1] Univ Messina, Ophthalmol Clin, Dept Surg Specialties, Messina, Italy
关键词
Intraocular pressure; Goldmann applanation tonometer; Dynamic contour tonometer; Corneal thickness; LASER PHOTOREFRACTIVE KERATECTOMY; IN-SITU KERATOMILEUSIS; HUMAN CADAVER EYES; GLAUCOMA; PATIENT; MYOPIA;
D O I
10.1159/000209253
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) in the evaluation of intraocular pressure (IOP) in eyes with different corneal thicknesses. Methods: GAT and DCT were performed in 70 eyes of 35 subjects aged between 21 and 59 years. Thirty eyes had normal, nonoperated corneas and 40 eyes had reduced central corneal thickness (CCT) following myopic photorefractive keratectomy. The GAT and DCT values were correlated to CCT and age and the agreement between both tonometers was determined by the Bland and Altman method. Results: GAT correlated strongly with CCT (p = 0.0002), but there was no correlation between DCT and CCT (p = 0.4388). No correlation was found between IOP values obtained with both devices and age. The Bland and Altman plot evidenced a lack of agreement between both tonometers with 95% limits of agreement between 1.6 and -5.6 mm Hg. Conclusions: GAT gives significantly lower values in the eyes with thin corneas and DCT is not influenced by CCT. DCT could be recommended to evaluate IOP in eyes with out-of-range corneal thickness. Copyright (C) 2009 S. Karger AG, Basel
引用
收藏
页码:244 / 249
页数:6
相关论文
共 50 条
  • [1] Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes
    Ceruti, P.
    Morbio, R.
    Marraffa, M.
    Marchini, G.
    EYE, 2009, 23 (02) : 262 - 269
  • [2] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    J Y F Ku
    H V Danesh-Meyer
    J P Craig
    G D Gamble
    C N J McGhee
    Eye, 2006, 20 : 191 - 198
  • [3] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    Ku, JYF
    Danesh-Meyer, HV
    Craig, JP
    Gamble, GD
    McGhee, CNJ
    EYE, 2006, 20 (02) : 191 - 198
  • [4] Dynamic contour tonometry and Goldmann applanation tonometry: correlation with intracameral assessment of intraocular pressure
    Riva, Ivano
    Quaranta, Luciano
    Russo, Andrea
    Katsanos, Andreas
    Rulli, Eliana
    Floriani, Irene
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (01) : 55 - 62
  • [5] Goldmann applanation tonometry and dynamic contour tonometry in eyes with elevated intraocular pressure (IOP): comparison in the same eyes after subsequent medical normalization of IOP
    Yoo, Chungkwon
    Eom, Young Sub
    Kim, Yong Yeon
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (11) : 1611 - 1616
  • [6] Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes
    P Ceruti
    R Morbio
    M Marraffa
    G Marchini
    Eye, 2009, 23 : 262 - 269
  • [7] Comparison of Goldmann applanation tonometry,, rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes
    Ozcura, Fatih
    Yildirim, Nilgun
    Sahin, Afsun
    Colak, Ertugrul
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (02) : 299 - 304
  • [8] Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Keratoconus
    Unterlauft, Jan Darius
    Schaedle, Nina
    Kasper, Karsten
    Klink, Thomas
    Geerling, Gerd
    CORNEA, 2011, 30 (10) : 1078 - 1082
  • [9] Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK
    Shemesh, Gabi
    Soiberman, Uri
    Kurtz, Shimon
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 1967 - 1970
  • [10] Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry
    Hsu, S-Y
    Sheu, M-M
    Hsu, A-H
    Wu, K-Y
    Yeh, J-I
    Tien, J-N
    Tsai, R-K
    EYE, 2009, 23 (07) : 1582 - 1588