We aimed to determine the reliability, accuracy and the clinical role of digital templating in the pre-operative work-up for total knee replacement. Initially a sample of ten pre-operative digital radiographs were templated by four independent observers to determine the inter- and intra-observer reliability of the process. Digital templating was then performed on the radiographs of 40 consecutive patients undergoing total knee replacement by a consultant surgeon not involved with the operation, who was blinded to the size of the implant inserted. The Press Fit Condylar Sigma Knee system was used in all the patients. The size of the implant as judged by templating was then compared to that of the size used. Good inter- and intra-observer agreement was demonstrated for both femoral and tibial templating. However, the correct size of the implant was predicted in only 48% of the femoral and 55% of the tibial components. Albeit reproducible, digital templating does not currently predict the correct size of component often enough to be of clinical benefit.
引用
收藏
页码:903 / 906
页数:4
相关论文
共 16 条
  • [1] Chin Kingsley R, 2002, J Knee Surg, V15, P213
  • [2] A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating
    Conn, KS
    Clarke, MT
    Hallett, JP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (02): : 269 - 272
  • [3] Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty
    Dutton, Andrew Quoc
    Yeo, Seng-Jin
    Yang, Kuang-Ying
    Lo, Ngai-Nung
    Chia, Kui-Un
    Chong, Hwei-Chi
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (01) : 2 - 9
  • [4] Fleiss JL., 1981, STAT METHODS RATES P, V2
  • [5] The failed total knee arthroplasty: Evaluation and etiology
    Gonzalez, MH
    Mekhail, AO
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (06) : 436 - 446
  • [6] Kinemax total knee arthroplasty - Trial by template
    Heal, J
    Blewitt, N
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (01) : 90 - 94
  • [7] Anthropometric measurements of the human knee: Correlation to the sizing of current knee arthroplasty systems
    Hitt, K
    Shurman, JR
    Greene, K
    McCarthy, J
    Moskal, J
    Hoeman, T
    Mont, MA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 115 - 122
  • [8] The role of preoperative templating in total knee arthroplasty: Comparison of three prostheses
    Howcroft, D. W. J.
    Fehily, M. J.
    Peck, C.
    Fox, A.
    Dillon, B.
    Johnson, D. S.
    [J]. KNEE, 2006, 13 (06) : 427 - 429
  • [9] Disc calibration for digital templating in hip replacement
    Kulkarni, A.
    Partington, P.
    Kelly, D.
    Muller, S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (12): : 1623 - 1626
  • [10] LASKIN RS, 2001, CONTROVERSIES TOTAL