摘要
This paper analyzes different noise components in MEMS gyroscope silicon structure, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and the improved differential interface is proposed based on weak signal detection technology, after that, the noise components in silicon structure are introduced and analyzed in sense open loop. The quadrature error (QE) signal automatically cancellation loop is proposed, and the results of the experiment indicate that the equivalent angular rates of QE and IPN are 46 degrees/s and 4.55 degrees/s respectively. The interfaces contrast experiments show that the DC noise and the useful signal amplitudes of differential and single-side detection interfaces are -49.8 dBmV, -16.8 dBmV and -39.8 dBmV (-42.1 dBmV), -22.1 dBmV (-22.2 dBmV), which confirms the differential interface has better SNR. The carrier experiments also illustrate that higher carrier frequency (from 500 kHz to 10 MHz) can restrain DC noise (from -19.8 dBmV to -54.2 dBmV) better, which demonstrate the FN is the dominant noise component of the silicon structure under normal temperature. The temperature experiments show the DC noise enhances from -48.5 dBmV to -14.6 dBmV over the range 20 degrees C to 60 degrees C while the useful signal amplitude remains around -16.6dBmV, and this phenomenon indicates the MTN and ETN become the dominant structure noise components gradually with temperature rising. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1209 / 1220
页数:12
相关论文
共 22 条
[1]   Mechanical-thermal noise in micromachined gyros [J].
Annovazzi-Lodi, V ;
Merlo, S .
MICROELECTRONICS JOURNAL, 1999, 30 (12) :1227-1230
[2]  
Bao M-H., 2000, Micro Mechanical Transducers: Pressure Sensors, Accelerometers and Gyroscopes
[3]   Investigation of a vacuum packaged MEMS gyroscope architecture's temperature robustness [J].
Cao, Huiliang ;
Li, Hongsheng .
INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2013, 41 (04) :495-506
[4]   Plasma-Sprayed Ceramic Coatings for Osseointegration [J].
Cao, Huiliang ;
Liu, Xuanyong .
INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2013, 10 (01) :1-10
[5]   Parameter optimization for a high-order band-pass continuous-time sigma-delta modulator MEMS gyroscope using a genetic algorithm approach [J].
Chen, Fang ;
Chang, Honglong ;
Yuan, Weizheng ;
Wilcock, Reuben ;
Kraft, Michael .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (10)
[6]   MECHANICAL-THERMAL NOISE IN MICROMACHINED ACOUSTIC AND VIBRATION SENSORS [J].
GABRIELSON, TB .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (05) :903-909
[7]  
Kim D, 2012, P AMER CONTR CONF, P92
[8]   Bias Prediction for MEMS Gyroscopes [J].
Kirkko-Jaakkola, Martti ;
Collin, Jussi ;
Takala, Jarmo .
IEEE SENSORS JOURNAL, 2012, 12 (06) :2157-2163
[9]   Noise analysis and characterization of a sigma-delta/capacitive microaccelerometer [J].
Külah, H ;
Chae, J ;
Yazdi, N ;
Najafi, K .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2006, 41 (02) :352-361
[10]   Mechanical-thermal noise in MEMS gyroscopes [J].
Leland, RP .
IEEE SENSORS JOURNAL, 2005, 5 (03) :493-500