Kinematics of a cementless mobile bearing posterior cruciate ligament-retaining total knee arthroplasty

被引:13
作者
Chouteau, J. [1 ,2 ,3 ,4 ,5 ]
Lerat, J. [1 ]
Testa, R. [1 ,2 ,3 ,4 ]
moyen, B. [1 ,2 ,3 ,4 ]
Fessy, M. H. [1 ,2 ,3 ,4 ]
Banks, S. A. [5 ]
机构
[1] Ctr Hosp Lyon Sud, Serv Chirurg Orthoped Traumatol & Med Sport, F-69495 Pierre Benite, France
[2] Univ Lyon 1, F-69003 Lyon, France
[3] Inst Natl Rech Transports & Leur Securite, F-69675 Bron, France
[4] Fac Med Lyon Sud, UMR T 0406, Lab Biomecan & Mecan Chocs, F-69921 Oullins, France
[5] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
关键词
Kinematics; Posterior cruciate ligament retaining; Total knee arthroplasty; Mobile bearing; IN-VIVO KINEMATICS; FLUOROSCOPIC ANALYSIS; ROTATING PLATFORM; FIXED-BEARING; DEEP FLEXION; PROSTHESIS; MOTION; REPLACEMENTS; DESIGN;
D O I
10.1016/j.knee.2008.11.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Mobile bearing (MB) total knee arthroplasty (TKA) was developed to provide low contact stress and unconstrained joint motion. We studied a consecutive series of 41 knees with mobile-bearing, posterior cruciate-retaining (CR) TKAs to determine if kinematics resembled normal knees or if kinematics changed over time. Patients were studied at 3 and 21 months average follow-up with weight-bearing radiographs at full extension, 30 degrees flexion and maximum flexion. Shape-matching techniques were used to measure TKA kinematics. Implant hyperextension, maximum flexion and total ROM increased with follow-up. Tibial rotation and condylar translations did not change with time. The medial condyle did not translate from extension to 30 degrees, but translated 5 mm anteriorly from 30 degrees to maximum flexion. Lateral condylar translation was 3 mm posterior from extension to 30 degrees, with no translation from 30 degrees to maximum flexion. Tibiofemoral kinematics in CR-MB-TKAs were stable over time, but did not replicate motions observed in healthy knees. The mobile tibial insert showed rotation and translation at both follow-up examinations, but the patterns of translation were not predictable. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 36 条
[1]   The influence of an anterior-posterior gliding mobile bearing on range of motion after total knee arthroplasty - A prospective, randomized, double-blinded study [J].
Aigner, C ;
Windhager, R ;
Pechmann, M ;
Rehak, P ;
Engeleke, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2257-2262
[2]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[3]   Implant design affects knee arthroplasty kinematics during stair-stepping [J].
Banks, SA ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :187-193
[4]   Making sense of knee arthroplasty kinematics: News you can use [J].
Banks, SA ;
Harman, MK ;
Bellemans, J ;
Hodge, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :64-72
[5]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[6]   Mechanism of anterior impingement damage in total knee arthroplasty [J].
Banks, SA ;
Harman, MK ;
Hodge, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A :37-42
[7]   Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[8]   The influence of tibial slope on maximal flexion after total knee arthroplasty [J].
Bellemans, J ;
Robijns, F ;
Duerinckx, J ;
Banks, S ;
Vandenneucker, H .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) :193-196
[9]   Effects of radiograph projection parameter uncertainty on TKA kinematics from model-image registration [J].
Chouteau, J. ;
Lerat, J. L. ;
Testa, R. ;
Moyen, B. ;
Banks, S. A. .
JOURNAL OF BIOMECHANICS, 2007, 40 (16) :3744-3747
[10]  
CHOUTEAU J, 2008, J ARTH IN PRESS 0811