Development and validation of a cost-effective, efficient, and robust liquid chromatographic method for the simultaneous determination of the acetyl and succinoyl content in hydroxypropyl methylcellulose acetate succinate polymer

被引:0
作者
Chen, R [1 ]
Sekulic, S [1 ]
Zelesky, T [1 ]
机构
[1] Pfizer Inc, Global Res & Dev, Pharmaceut Sci, Analyt RD,Groton Labs, Groton, CT 06340 USA
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reversed-phase liquid chromatographic method was developed and validated for the determination of the content of free acetic acid, free succinic acid, acetyl substituents, and succinoyl substituents in hydroxypropyl methylcellulose acetate succinate (HPMCAS; Chemical Abstracts Service Registry No. 71138-97-1) polymer. This single new method gave accurate and precise measurement of both acetyl and succinoyl substituents, which had previously required 3 Japanese Pharmaceutical Excipients (JPE) methods to accomplish. Consequently, analysis time and turnaround time are decreased significantly. Furthermore, this method can also separate and determine the free acetic and succinic acids in HPMCAS polymer, a task that the corresponding JPE method cannot achieve. The values for accuracy (average recovery from 12 standard samples) were 99.9% for acetic acid and 99.8% for succinic acid. The values for injection precision (relative standard deviation [RSD]) were 0.11% for acetic acid and 0.28% for succinic acid. The values for intermediate precision (RSD) were 1.25% for determination of the acetyl content at the 8.78% (w/w) level and 1.33% for determination of the succinoyl content at the 10.9% (w/w) level. The values for intermediate precision (RSD) were 5.98% for determination of free acetic acid at the 0.12% (w/w) level and 5.13% for determination of free succinic acid at the 0.029% (w/w) level. The method was proven to be robust with respect to variation in the pH of the mobile phase, the concentration of potassium dihydrogen phosphate, and the flow rate. The method is well suited for quality control in today's fast-paced pharmaceutical laboratories.
引用
收藏
页码:824 / 831
页数:8
相关论文
共 13 条
  • [1] *ASTM, 1997, D81796 ASTM
  • [2] *ASTM, 1997, D87196 ASTM
  • [3] DETERMINATION OF THE ACIDIC DEGRADATION PRODUCTS, ACETIC, PROPIONIC, BUTYRIC, AND PHTHALIC-ACID IN AQUEOUS PSEUDOLATEXES OF CELLULOSIC ESTERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BODMEIER, R
    CHEN, HG
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1991, 17 (13) : 1811 - 1822
  • [4] Guyton AC, 1996, TXB MED PHYSL, P817
  • [5] NAGAI T, 1997, AQUEOUS POLYM COATIN, V79, P177
  • [6] Onda Y., 1980, US Patent Office, Patent No. [4,226,981, 4226981]
  • [7] Determination of the degree of succinylation in diverse modified starches by Raman spectroscopy
    Phillips, DL
    Xing, J
    Chong, CK
    Liu, HJ
    Corke, H
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (11) : 5105 - 5108
  • [8] Swartz MichaelE., 1997, ANAL METHOD DEV VALI
  • [9] PREPARATION OF POLYESTER SAMPLES FOR COMPOSITION ANALYSIS
    TINDALL, GW
    PERRY, RL
    LITTLE, JL
    SPAUGH, AT
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (13) : 1251 - 1256
  • [10] DETERMINATION OF ESTER SUBSTITUENTS IN CELLULOSE ESTERS
    TINDALL, GW
    PERRY, RL
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2): : 227 - 233