SURGE PROTECTIVE DEVICES SELECTION FOR TRUE INSTALLATIONS

被引:0
|
作者
Rousseau, Alain [1 ]
Gruet, Pierre [2 ]
机构
[1] SEFTIM, Vincennes, France
[2] INERIS, Vincennes, France
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper intends to show how to select SPDs in practical applications when standards only gives general rules. This addresses the selection of voltage protection level lip and the value of current limp. Based on these two values an SPD can be determined and appropriate selection of these two parameters is then important. lEC 62305- 2 allows to determine the Lightning Protection Level ( LPL). Based on this, the current circulating inside an SPD can be determined using simple calculation or a more sophisticated one. Based on the LPL, the probability of protection of the SPD can also be determined and this is related to the current withstand of the SPD and also to its voltage protection level even if this last parameter is less easy to assess in spite of being fundamental.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Requirements on surge protective devices for high speed data line networks
    Holterhoff, Martin
    2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [32] The overvoltage dangers in electrical installation with multistep circuits with surge protective devices
    Sowa, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11B): : 185 - 187
  • [33] Protection distance of surge protective devices in low voltage distribution systems
    Zhang D.
    Fu Z.-C.
    Zhao G.
    Sun W.
    J. Shanghai Jiaotong Univ. Sci., 2008, 4 (477-481): : 477 - 481
  • [34] Protection Distance of Surge Protective Devices in Low Voltage Distribution Systems
    张栋
    傅正财
    赵刚
    孙伟
    JournalofShanghaiJiaotongUniversity(Science), 2008, (04) : 477 - 481
  • [35] Lingering lead length legacies in surge-protective devices applications
    Martzloff, FD
    Phipps, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) : 151 - 157
  • [36] Failure rate estimation of MOV for condition monitoring of surge protective devices
    Kim, Y.S. (yskim@joongbu.ac.kr), 1600, Korean Institute of Electrical Engineers (62):
  • [37] Waterproof Surge Protective Grounding Devices for HV Power Cable Lines
    Luo, Junhua
    Zhang, Li
    Li, Huachun
    Luo, Min
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 253 - +
  • [38] Lightning and surge protection in photovoltaic installations
    Hernandez, Jesus C.
    Vidal, Pedro G.
    Jurado, Francisco
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1961 - 1971
  • [39] SELECTION AND USE OF RESPIRATORY PROTECTIVE DEVICES.
    Ruschena, Leo
    CEA, Chemical Engineering in Australia, 1982, ChE 7 (02): : 43 - 48
  • [40] High demands on cellular networks-high demands on surge protective devices
    Bissmeier, Ralf
    INTELEC 2006: 28TH INTERNATIONAL TELECOMMUNICATION ENERGY CONFERENCE, VOLS 1 AND 2, 2006, : 208 - 211