3.0 T versus 1.5 T MR angiography of the head and neck

被引:17
作者
DeLano, MC [1 ]
DeMarco, JK [1 ]
机构
[1] Michigan State Univ, Dept Radiol, E Lansing, MI 48824 USA
关键词
D O I
10.1016/j.nic.2006.03.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This article presents the advantages and challenges of MR angiography of the intracranial and extracranial cerebral vasculature at 3.0 T with comparative assessment to 1.5 T approaches. The physical basis for the superiority of 3.0 T MR angiography is discussed in the context of evolving technological capabilities afforded by the synergistic advent of higher field scanners, improved coil design, and parallel imaging. This review emphasizes 3.0 T issues related to noncontrast three-dimensional time of flight MR angiography of the intracranial circulation, contrast enhanced three-dimensional time of flight MR angiography of the extracranial cerebral vasculature, and carotid plaque characterization.
引用
收藏
页码:321 / +
页数:22
相关论文
共 75 条
[1]   Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries [J].
Al-Kwifi, O ;
Emery, DJ ;
Wilman, AH .
MAGNETIC RESONANCE IMAGING, 2002, 20 (02) :181-187
[2]  
Alvarez-Linera J, 2003, AM J NEURORADIOL, V24, P1012
[3]   MEASUREMENT OF INTERNAL CAROTID-ARTERY STENOSIS FROM SOURCE MR ANGIOGRAMS [J].
ANDERSON, CM ;
LEE, RE ;
LEVIN, DL ;
ALONSO, SD ;
SALONER, D .
RADIOLOGY, 1994, 193 (01) :219-226
[4]   Carotid artery stenosis: Intraindividual correlations of 3D time-of-flight MR angiography, contrast-enhanced MR angiography, conventional DSA, and rotational angiography for detection and grading [J].
Anzalone, N ;
Scomazzoni, F ;
Castellano, R ;
Strada, L ;
Righi, C ;
Politi, LS ;
Kirchin, MA ;
Chiesa, R ;
Scotti, G .
RADIOLOGY, 2005, 236 (01) :204-213
[5]   Grading of carotid artery stenosis using high resolution dynamic magnetic resonance angiography in comparison to intraarterial digital subtraction angiography. Are stenoses over 70% reliably detectable? [J].
Aschenbach, R ;
Eger, C ;
Basche, S ;
Vogl, TJ .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (03) :357-362
[6]  
Bernstein MA, 2001, MAGNET RESON MED, V46, P955, DOI 10.1002/mrm.1282
[7]  
Borisch I, 2003, AM J NEURORADIOL, V24, P1117
[8]   Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 tesla [J].
Botnar, RM ;
Stuber, M ;
Lamerichs, R ;
Smink, J ;
Fischer, SE ;
Harvey, P ;
Manning, WJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (04) :589-594
[9]   High-resolution contrast-enhanced magnetic resonance angiography of the carotid arteries using fluoroscopic monitoring of contrast arrival: Diagnostic accuracy and interobserver variability [J].
Butz, B ;
Dorenbeck, U ;
Borisch, I ;
Zorger, N ;
Lenhart, M ;
Feuerbach, S ;
Link, J .
ACTA RADIOLOGICA, 2004, 45 (02) :164-170
[10]  
Campeau N G, 2001, Top Magn Reson Imaging, V12, P183, DOI 10.1097/00002142-200106000-00005