Use of an anatomical mid-sagittal plane for 3-dimensional cephalometry: A preliminary study

被引:9
作者
Vernucci, Roberto Antonio [1 ]
Aghazada, Huseynagha [1 ]
Gardini, Kelly [1 ]
Fegatelli, Danilo Alunni [2 ]
Barbato, Ersilia [1 ]
Galluccio, Gabriella [1 ]
Silvestri, Alessandro [1 ]
机构
[1] Sapienza Univ Rome, Sch Dent, Dept Oral & Maxillofacial Sci, Via Caserta 6, I-00161 Rome, Italy
[2] Sapienza Univ Rome, Dept Publ Hlth Infect Dis, Rome, Italy
关键词
Cephalometry; Cone-Beam Computed Tomography; Dimensional Measurement Accuracy; BEAM COMPUTED-TOMOGRAPHY; LANDMARK IDENTIFICATION; FACIAL ASYMMETRY; RELIABILITY; IMAGES; REPRODUCIBILITY; ACCURACY; MULTIPLANAR;
D O I
10.5624/isd.2019.49.2.159
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Cone-beam computed tomography (CBCT) is widely used for 3-dimensional assessments of cranio-maxillo-facial relationships, especially in patients undergoing orthognathic surgery. We have introduced, for reference in CBCT cephalometry, an anatomical mid-sagittal plane (MSP) identified by the nasion, the midpoint between the posterior clinoid processes of the sella turcica, and the basion. The MSP is an updated version of the median plane previously used at our institution for 2D posterior-anterior cephalometry. This study was conducted to test the accuracy of the CBCT measures compared to those obtained using standard posterior-anterior cephalometry. Materials and Methods: Two operators measured the inter-zygomatic distance on 15 CBCT scans using the MSP as a reference plane, and the CBCT measurements were compared with measurements made on patients' posterior-anterior cephalograms. The statistical analysis evaluated the absolute and percentage differences between the 3D and 2D measurements. Results: As demonstrated by the absolute mean difference (roughly 1 mm) and the percentage difference (less than 3%), the MSP showed good accuracy on CBCT compared to the 2D plane, especially for measurements of the left side. However, the CBCT measurements showed a high standard deviation, indicating major variability and low precision. Conclusion: The anatomical MSP can be used as a reliable reference plane for transverse measurements in 3D cephalometry in cases of symmetrical or asymmetrical malocclusion. In patients who suffer from distortions of the skull base, the identification of landmarks might be difficult and the MSP could be unreliable. Becoming familiar with the relevant software could reduce errors and improve reliability.
引用
收藏
页码:159 / 169
页数:11
相关论文
共 50 条
  • [41] Accuracy of 3-Dimensional Virtual Surgical Simulation Combined With Digital Teeth Alignment: A Pilot Study
    Kim, Jung-Hoon
    Park, Young-Chel
    Yu, Hyung-Seog
    Kim, Moon-Key
    Kang, Sang-Hoon
    Choi, Yoon Jeong
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (11) : 2441.e1 - 2441.e13
  • [42] Effect of Ambient Lights on the Accuracy of a 3-Dimensional Optical Scanner for Face Scans: An In Vitro Study
    Thongma-Eng, Punrit
    Amornvit, Pokpong
    Silthampitag, Patcharawan
    Rokaya, Dinesh
    Pisitanusorn, Attavit
    JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [43] Aortic Annular Sizing Using a Novel 3-Dimensional Echocardiographic Method Use and Comparison With Cardiac Computed Tomography
    Khalique, Omar K.
    Kodali, Susheel K.
    Paradis, Jean-Michel
    Nazif, Tamim M.
    Williams, Mathew R.
    Einstein, Andrew J.
    Pearson, Gregory D.
    Harjai, Kishore
    Grubb, Kendra
    George, Isaac
    Leon, Martin B.
    Hahn, Rebecca T.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2014, 7 (01) : 155 - 163
  • [44] Comparison Between Amide Proton Transfer Magnetic Resonance Imaging Using 3-Dimensional Acquisition and Diffusion-Weighted Imaging for Characterization of Prostate Cancer: A Preliminary Study
    Kido, Ayumu
    Tamada, Tsutomu
    Ueda, Yu
    Takeuchi, Mitsuru
    Kanki, Akihiko
    Yamamoto, Akira
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 178 - 185
  • [45] A comparative study of the normal oesophageal wall thickness based on 3-dimensional, 4-dimensional, and cone beam computed tomography
    Hu, Chao Yue
    Li, Yan Kang
    Li, Jian Bin
    Wang, Jin Zhi
    Shao, Qian
    Wang, Wei
    Guo, Yan Luan
    Xu, Min
    Li, Wen Wu
    MEDICINE, 2020, 99 (45) : E22553
  • [46] Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique
    Lo Giudice, Antonino
    Quinzi, Vincenzo
    Ronsivalle, Vincenzo
    Farronato, Marco
    Nicotra, Carmelo
    Indelicato, Francesco
    Isola, Gaetano
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (13) : 1 - 15
  • [47] Comparison of user satisfaction and image quality of fixed and mobile camera systems for 3-dimensional image capture of edentulous patients: A pilot clinical study
    Sailer, Irena
    Liu, Shiming
    Moerzinger, Roland
    Lancelle, Marcel
    Beeler, Thabo
    Gross, Markus
    Wu, Chenglei
    Fehmer, Vincent
    Srinivasan, Murali
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (04) : 520 - 524
  • [48] Prevalence, clinical characteristics, and 3-dimensional radiographic analysis of supernumerary teeth in Guangzhou, China: a retrospective study
    He, Lidan
    Que, Guoying
    Yang, Xiaoxia
    Yan, Siqi
    Luo, Song
    BMC ORAL HEALTH, 2023, 23 (01)
  • [49] Effect of Short-Term 3-Dimensional Schroth Exercises In Adolescent Idiopathic Scoliosis: An Observational Study
    Aktan, Deniz
    Erdoganoglu, Yildiz
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2021, 44 (08) : 612 - 620
  • [50] In vivo 3-Dimensional Kinematics Study of the Healthy Cervical Spine Based on CBCT Combined with 3D-3D Registration Technology
    Tang, Benyu
    Yao, Haoqun
    Wang, Shaobai
    Zhong, Yanlong
    Cao, Kai
    Wan, Zongmiao
    SPINE, 2021, 46 (24) : E1301 - E1310