Use of an anatomical mid-sagittal plane for 3-dimensional cephalometry: A preliminary study

被引:9
作者
Vernucci, Roberto Antonio [1 ]
Aghazada, Huseynagha [1 ]
Gardini, Kelly [1 ]
Fegatelli, Danilo Alunni [2 ]
Barbato, Ersilia [1 ]
Galluccio, Gabriella [1 ]
Silvestri, Alessandro [1 ]
机构
[1] Sapienza Univ Rome, Sch Dent, Dept Oral & Maxillofacial Sci, Via Caserta 6, I-00161 Rome, Italy
[2] Sapienza Univ Rome, Dept Publ Hlth Infect Dis, Rome, Italy
关键词
Cephalometry; Cone-Beam Computed Tomography; Dimensional Measurement Accuracy; BEAM COMPUTED-TOMOGRAPHY; LANDMARK IDENTIFICATION; FACIAL ASYMMETRY; RELIABILITY; IMAGES; REPRODUCIBILITY; ACCURACY; MULTIPLANAR;
D O I
10.5624/isd.2019.49.2.159
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Cone-beam computed tomography (CBCT) is widely used for 3-dimensional assessments of cranio-maxillo-facial relationships, especially in patients undergoing orthognathic surgery. We have introduced, for reference in CBCT cephalometry, an anatomical mid-sagittal plane (MSP) identified by the nasion, the midpoint between the posterior clinoid processes of the sella turcica, and the basion. The MSP is an updated version of the median plane previously used at our institution for 2D posterior-anterior cephalometry. This study was conducted to test the accuracy of the CBCT measures compared to those obtained using standard posterior-anterior cephalometry. Materials and Methods: Two operators measured the inter-zygomatic distance on 15 CBCT scans using the MSP as a reference plane, and the CBCT measurements were compared with measurements made on patients' posterior-anterior cephalograms. The statistical analysis evaluated the absolute and percentage differences between the 3D and 2D measurements. Results: As demonstrated by the absolute mean difference (roughly 1 mm) and the percentage difference (less than 3%), the MSP showed good accuracy on CBCT compared to the 2D plane, especially for measurements of the left side. However, the CBCT measurements showed a high standard deviation, indicating major variability and low precision. Conclusion: The anatomical MSP can be used as a reliable reference plane for transverse measurements in 3D cephalometry in cases of symmetrical or asymmetrical malocclusion. In patients who suffer from distortions of the skull base, the identification of landmarks might be difficult and the MSP could be unreliable. Becoming familiar with the relevant software could reduce errors and improve reliability.
引用
收藏
页码:159 / 169
页数:11
相关论文
共 50 条
  • [21] Easy, Fast, and Accurate Method of 3-Dimensional Mirror Plane Creation for Actual Clinical Users
    Kwon, Min-Soo
    Lee, Hyunwoo
    Hwang, Bo-Yeon
    Lee, Jung-Woo
    APPLIED SCIENCES-BASEL, 2020, 10 (17):
  • [22] Role of 3-Dimensional Sonography in the Assessment of Submucous Fibroids: A Pilot Study
    Keizer, Alieke L.
    Nieuwenhuis, Lotte L.
    Twisk, Jos W. R.
    Huirne, Judith A. F.
    Hehenkamp, Wouter J. K.
    Broelmann, Hans A. M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (01) : 191 - 199
  • [23] Does Alt-RAMEC protocol and facemask treatment affect dentoalveolar structures? A 3-dimensional study
    Ozbilen, Elvan Onem
    Yilmaz, Hanife Nuray
    Acar, Yasemin Bahar
    ANGLE ORTHODONTIST, 2021, 91 (05) : 626 - 633
  • [24] Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging
    Montreuil, Julien
    Saleh, Joseph
    Cresson, Thierry
    De Guise, Jacques A.
    Lavoie, Frederic
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (04)
  • [25] Morphologic reproducibility in 6 regions of the 3-dimensional facial models acquired by a standardized procedure: An in vivo study
    Wang, Xin-wen
    Liu, Zi-jin
    Diao, Jing
    Zhao, Yi-jiao
    Jiang, Jiu-hui
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (03) : E287 - E295
  • [26] Using an additively manufactured natural head position reference device to transfer the horizon orientation plane and integrate it with a 3-dimensional virtual patient: A dental technique
    Rosmaninho, Alberto
    Zeitler, Jonathan M.
    Vedovato, Euripedes
    Kois, John C.
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01) : 7 - 12
  • [27] Assessing agreement in measurements of orthodontic study models: Digital caliper on plaster models vs 3-dimensional software on models scanned by structured-light scanner
    Hassan, Wan Nurazreena Wan
    Othman, Siti Adibah
    Chan, Chee Seng
    Ahmad, Roshahida
    Ali, Siti Nor'Ain
    Rohim, Anis Abd
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (05) : 886 - 895
  • [28] Advantages of 3-dimensional Measurements for Supraspinatus Intramuscular Fatty Evaluation in Patients With Medium to Massive Rotator Cuff Tears: Comparison With a Single Sagittal Slice
    Liu, Beibei
    Xu, Junjie
    Jin, Yuchen
    Su, Wei
    Zhang, Xiuyuan
    Qiao, Yi
    Yu, Weibin
    Cheng, Lude
    Zhao, Jinzhong
    Li, Yuehua
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (03) : 699 - 707
  • [29] Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study
    Oh, Song Hee
    Kang, Ju Hee
    Seo, Yu-Kyeong
    Lee, Sae Rom
    Choi, Hwa-Young
    Choi, Yong-Suk
    Hwang, Eui-Hwan
    IMAGING SCIENCE IN DENTISTRY, 2018, 48 (02) : 111 - 119
  • [30] Feasibility of Measuring 3-Dimensional Renal Parenchymal Volume to Predict Postnatal Renal Function in Near-Term Fetuses With Congenital Hydronephrosis A Preliminary Study
    Nam, Ka Hyun
    Cho, Arthur
    Kwon, Ja Young
    Park, Yong Won
    Kim, Young Han
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (06) : 955 - 962