Smoke Flow in Chinese Kangs

被引:16
作者
Zhuang, Zhi [1 ,2 ]
Li, Yuguo [2 ]
Chen, Bin [1 ]
机构
[1] Dalian Univ Technol, Bldg Environm & New Energy Resource Lab, Sch Civil & Hydraul Engn, Dalian 116024, Peoples R China
[2] Univ Hong Kong, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Chinese kang; Elevated kang; Macroscopic model; Smoke backflow;
D O I
10.1177/1420326X09105454
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Chinese kangs are widely used today, in nearly 85% of rural homes by 175 million people in Northern China. While Chinese kangs are a potentially energy sustainable solution for home heating, existing systems are characterized by their poor energy efficiency and significant concerns about the impact of indoor air pollution in homes caused by smoke backflow or smoke leakages. Existing kang designs are based on the intuition and historical accumulation of past craftsmanship experiences. As the first attempt, a macroscopic thermal-fluid approach is used to model the airflow and heat transfer process of an elevated kang with a focus on smoke flow. This model considers nonlinear interaction of thermal buoyancy force, wind force and heat transfer from kang plates and chimney walls. Five parameter groups are identified for characterizing the kang systems to guide the kang smoke flow design. Our work has explained the so-called smoke backflow phenomenon that can lead to serious indoor air quality problems in rural homes and based on the results, we have provided some design recommendations for avoiding smoke backflow, and for enhancing energy efficiency by increasing the heat utilization of the kang body.
引用
收藏
页码:219 / 233
页数:15
相关论文
共 16 条
[1]  
ANDERSEN KT, 2003, BUILD ENVIRON, V11, P1281
[2]  
ANDERSEN KT, 2007, BUILD ENVIRON, V2, P534
[3]  
Bruce N, 2000, B WORLD HEALTH ORGAN, V78, P1078
[4]   Selected major risk factors and global and regional burden of disease [J].
Ezzati, M ;
Lopez, AD ;
Rodgers, A ;
Vander Hoorn, S ;
Murray, CJL .
LANCET, 2002, 360 (9343) :1347-1360
[5]   Indoor air pollution from biomass combustion and acute respiratory infections in Kenya: an exposure-response study [J].
Ezzati, M ;
Kammen, DM .
LANCET, 2001, 358 (9282) :619-624
[6]  
Idelchik I., 1993, Handbook of hydraulic resistance
[7]  
LI YG, 2001, BUILD ENVIRON, V7, P851
[8]  
LI YG, 2002, ANAL NATURAL SMOKE F
[9]  
LI YG, 2001, BUILD ENVIRON, V1, P59
[10]  
Li Z., 2005, THESIS SICHUAN U