Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

被引:43
作者
Richter, Daniel [1 ,2 ]
Saito, Nami [1 ]
Chaudhri, Naved [3 ]
Haertig, Martin [4 ]
Ellerbrock, Malte [3 ]
Jaekel, Oliver [3 ,4 ]
Combs, Stephanie E. [4 ]
Habermehl, Daniel [4 ]
Herfarth, Klaus [4 ]
Durante, Marco [1 ,2 ]
Bert, Christoph [1 ,5 ,6 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, Dept Biophys, Darmstadt, Germany
[2] Tech Univ Darmstadt, Darmstadt, Germany
[3] Heidelberg Ion Beam Therapy Ctr, Dept Med Phys, Heidelberg, Germany
[4] Univ Heidelberg Hosp, Dept Radiat Oncol, Heidelberg, Germany
[5] Univ Clin Erlangen, Erlangen, Germany
[6] Univ Erlangen Nurnberg, Dept Radiat Oncol, D-91054 Erlangen, Germany
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2014年 / 89卷 / 01期
关键词
DEFORMABLE IMAGE REGISTRATION; RADIATION-THERAPY; RESPIRATORY MOTION; GATED IRRADIATION; PARTICLE BEAMS; RADIOTHERAPY; TARGETS; VERIFICATION; VALIDATION; ALGORITHM;
D O I
10.1016/j.ijrobp.2014.01.043
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)-weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V-95) and 107% (V-107) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V-95 and V-107 values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V-95 > 87%, SD < 3%) and overdose (mean V-107 < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment. (C) 2014 Elsevier Inc.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 31 条
[11]   Clinical Implementation of Gating and Dose Verification with Scanned Ion Beams at HIT [J].
Chaudhri, N. ;
Richter, D. ;
Haertig, M. ;
Ecker, S. ;
Ackermann, B. ;
Naumann, J. ;
Haberer, T. ;
Bert, C. ;
Habermehl, D. ;
Herfarth, K. ;
Ellerbrock, M. ;
Jaekel, O. .
MEDICAL PHYSICS, 2012, 39 (06) :3780-3781
[12]   Particle therapy at the Heidelberg Ion Therapy Center (HIT) - Integrated research-driven university-hospital-based radiation oncology service in Heidelberg, Germany [J].
Combs, Stephanie E. ;
Jaekel, Oliver ;
Haberer, Thomas ;
Debus, Juergen .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (01) :41-44
[13]   Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma - feasibility and clinical response [J].
Habermehl, Daniel ;
Debus, Juergen ;
Ganten, Tom ;
Ganten, Maria-Katharina ;
Bauer, Julia ;
Brecht, Ingo C. ;
Brons, Stephan ;
Haberer, Thomas ;
Haertig, Martin ;
Jaekel, Oliver ;
Parodi, Katia ;
Welzel, Thomas ;
Combs, Stephanie E. .
RADIATION ONCOLOGY, 2013, 8
[14]  
International Commission on Radiation Units and Measurements (ICRU), 1993, 50 ICRU
[15]  
Kaplan W, 2003, ADV CALCULUS, P90
[16]  
Leow A, 2005, LECT NOTES COMPUT SC, V3565, P493
[17]   4D patient dose reconstruction using online measured EPID cine images for lung SBRT treatment validation [J].
Lin, Mu-Han ;
Li, Jinsheng ;
Wang, Lu ;
Koren, Sion ;
Fan, Jiajing ;
Forkal, Eugene ;
Ma, C. -M. .
MEDICAL PHYSICS, 2012, 39 (10) :5949-5958
[18]   A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beam's eye view [J].
McMahon, Ryan ;
Berbeco, Ross ;
Nishioka, Seiko ;
Ishikawa, Masayori ;
Papiez, Lech .
MEDICAL PHYSICS, 2008, 35 (09) :3875-3888
[19]   Respiratory gated irradiation system for heavy-ion radiotherapy [J].
Minohara, S ;
Kanai, T ;
Endo, M ;
Noda, K ;
Kanazawa, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04) :1097-1103
[20]   Liver motion during cone beam computed tomography guided stereotactic body radiation therapy [J].
Park, Justin C. ;
Park, Sung Ho ;
Kim, Jong Hoon ;
Yoon, Sang Min ;
Song, Si Yeol ;
Liu, Zhaowei ;
Song, Bongyong ;
Kauweloa, Kevin ;
Webster, Matthew J. ;
Sandhu, Ajay ;
Mell, Loren K. ;
Jiang, Steve B. ;
Mundt, Arno J. ;
Song, William Y. .
MEDICAL PHYSICS, 2012, 39 (10) :6431-6442