Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

被引:42
作者
Richter, Daniel [1 ,2 ]
Saito, Nami [1 ]
Chaudhri, Naved [3 ]
Haertig, Martin [4 ]
Ellerbrock, Malte [3 ]
Jaekel, Oliver [3 ,4 ]
Combs, Stephanie E. [4 ]
Habermehl, Daniel [4 ]
Herfarth, Klaus [4 ]
Durante, Marco [1 ,2 ]
Bert, Christoph [1 ,5 ,6 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, Dept Biophys, Darmstadt, Germany
[2] Tech Univ Darmstadt, Darmstadt, Germany
[3] Heidelberg Ion Beam Therapy Ctr, Dept Med Phys, Heidelberg, Germany
[4] Univ Heidelberg Hosp, Dept Radiat Oncol, Heidelberg, Germany
[5] Univ Clin Erlangen, Erlangen, Germany
[6] Univ Erlangen Nurnberg, Dept Radiat Oncol, D-91054 Erlangen, Germany
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2014年 / 89卷 / 01期
关键词
DEFORMABLE IMAGE REGISTRATION; RADIATION-THERAPY; RESPIRATORY MOTION; GATED IRRADIATION; PARTICLE BEAMS; RADIOTHERAPY; TARGETS; VERIFICATION; VALIDATION; ALGORITHM;
D O I
10.1016/j.ijrobp.2014.01.043
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)-weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V-95) and 107% (V-107) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V-95 and V-107 values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V-95 > 87%, SD < 3%) and overdose (mean V-107 < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment. (C) 2014 Elsevier Inc.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 31 条
  • [11] Clinical Implementation of Gating and Dose Verification with Scanned Ion Beams at HIT
    Chaudhri, N.
    Richter, D.
    Haertig, M.
    Ecker, S.
    Ackermann, B.
    Naumann, J.
    Haberer, T.
    Bert, C.
    Habermehl, D.
    Herfarth, K.
    Ellerbrock, M.
    Jaekel, O.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3780 - 3781
  • [12] Particle therapy at the Heidelberg Ion Therapy Center (HIT) - Integrated research-driven university-hospital-based radiation oncology service in Heidelberg, Germany
    Combs, Stephanie E.
    Jaekel, Oliver
    Haberer, Thomas
    Debus, Juergen
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (01) : 41 - 44
  • [13] Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma - feasibility and clinical response
    Habermehl, Daniel
    Debus, Juergen
    Ganten, Tom
    Ganten, Maria-Katharina
    Bauer, Julia
    Brecht, Ingo C.
    Brons, Stephan
    Haberer, Thomas
    Haertig, Martin
    Jaekel, Oliver
    Parodi, Katia
    Welzel, Thomas
    Combs, Stephanie E.
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [14] International Commission on Radiation Units and Measurements (ICRU), 1993, 50 ICRU
  • [15] Kaplan W, 2003, ADV CALCULUS, P90
  • [16] Leow A, 2005, LECT NOTES COMPUT SC, V3565, P493
  • [17] 4D patient dose reconstruction using online measured EPID cine images for lung SBRT treatment validation
    Lin, Mu-Han
    Li, Jinsheng
    Wang, Lu
    Koren, Sion
    Fan, Jiajing
    Forkal, Eugene
    Ma, C. -M.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 5949 - 5958
  • [18] A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beam's eye view
    McMahon, Ryan
    Berbeco, Ross
    Nishioka, Seiko
    Ishikawa, Masayori
    Papiez, Lech
    [J]. MEDICAL PHYSICS, 2008, 35 (09) : 3875 - 3888
  • [19] Respiratory gated irradiation system for heavy-ion radiotherapy
    Minohara, S
    Kanai, T
    Endo, M
    Noda, K
    Kanazawa, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04): : 1097 - 1103
  • [20] Liver motion during cone beam computed tomography guided stereotactic body radiation therapy
    Park, Justin C.
    Park, Sung Ho
    Kim, Jong Hoon
    Yoon, Sang Min
    Song, Si Yeol
    Liu, Zhaowei
    Song, Bongyong
    Kauweloa, Kevin
    Webster, Matthew J.
    Sandhu, Ajay
    Mell, Loren K.
    Jiang, Steve B.
    Mundt, Arno J.
    Song, William Y.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6431 - 6442