The tungsten divertor experiment at ASDEX upgrade

被引:78
作者
Neu, R
Asmussen, K
Krieger, K
Thoma, A
Bosch, HS
Deschka, S
Dux, R
Engelhardt, W
GarciaRosales, C
Gruber, O
Herrmann, A
Kallenbach, A
Kaufmann, M
Mertens, V
Ryter, F
Rohde, V
Roth, J
Sokoll, M
Stabler, A
Suttrop, W
Weinlich, M
Zohm, H
Alexander, M
Becker, G
Behler, K
Behringer, K
Behrisch, R
Bergmann, A
BessenrodtWeberpals, M
Brambilla, M
Brinkschulte, H
Buchl, K
Carlson, A
Chodura, R
Coster, D
Cupido, L
deBlank, HJ
Hempel, SD
Drube, R
Fahrbach, HU
Feist, JH
Feneberg, W
Fiedler, S
Franzen, P
Fuchs, JC
Fussmann, G
Gafert, J
Gehre, O
Gernhardt, J
Haas, G
机构
[1] MAX PLANCK INST PLASMA PHYS, IPP, EURATOM, BERLIN, GERMANY
[2] CTR ESTUDIOS & INVEST TECN GUIPUZCOA, SAN SEBASTIAN, SPAIN
[3] CTR FUSAO NUCL, LISBON, PORTUGAL
[4] UNIV STUTTGART, INST PLASMAFORSCH, D-7000 STUTTGART, GERMANY
[5] FORSCHUNGSZENTRUM JULICH, JULICH, GERMANY
[6] UNIV COLL CORK, CORK, IRELAND
[7] INST NUCL TECHNOL & RADIAT PROTECT, ATHENS, GREECE
关键词
D O I
10.1088/0741-3335/38/12A/013
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Tungsten-coated tiles, manufactured by plasma spray on graphite, were mounted in the divertor of the ASDEX Upgrade tokamak and cover almost 90% of the surface facing the plasma in the strike zone. Over 600 plasma discharges have been performed to date, around 300 of which were auxiliary heated with heating powers up to 10 MW. The production of tungsten in the divertor was monitored by a W I line at 400.8 nm. In the plasma centre an array of spectral lines at 5 nm emitted by ionization states around W XXX was measured. From the intensity of these lines the W content was derived. Under normal discharge conditions W-concentrations around 10(-5) or even lower were found. The influence on the main plasma parameters was found to be negligible. The maximum concentrations observed decrease with increasing heating power. In several low power discharges accumulation of tungsten occurred and the temperature profile was Battened. The concentrations of the intrinsic impurities carbon and oxygen were comparable to the discharges with the graphite divertor. Furthermore, the density and the beta limits remained unchanged and no negative influence on the energy confinement or on the H-mode threshold was found. Discharges with neon radiative cooling showed the same behaviour as in the graphite divertor case.
引用
收藏
页码:A165 / A179
页数:15
相关论文
共 37 条
[1]  
ARUNASALAM V, 1978, P 8 C EPS PRAG 1977, V2, P17
[2]  
ASMUSSEN K, 1996, 102 IPP
[3]  
ASMUSSEN K, IN PRESS
[4]  
DUX R, 1996, P 23 EPS C CONTR FUS
[5]   A spatially scanning vacuum ultraviolet and visible range spectrometer for spectroscopy of tokamak plasmas in ASDEX-Upgrade [J].
Field, AR ;
Fink, J ;
Dux, R ;
Fussmann, G ;
Wenzel, U ;
Schumacher, U .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12) :5433-5441
[6]   EROSION PROCESSES IN PLASMA-WALL INTERACTIONS [J].
GARCIAROSALES, C .
JOURNAL OF NUCLEAR MATERIALS, 1994, 211 (03) :202-214
[7]  
GARCIAROSALES C, IN PRESS ASDEX UPGRA
[8]   POWER BALANCE AND SCALING OF THE RADIATED POWER IN THE DIVERTOR AND MAIN PLASMA OF ALCATOR C-MOD [J].
GOETZ, JA ;
LIPSCHULTZ, B ;
GRAF, MA ;
KURZ, C ;
NACHTRIEB, R ;
SNIPES, JA ;
TERRY, JL .
JOURNAL OF NUCLEAR MATERIALS, 1995, 220 :971-975
[9]   ENERGY FLUX TO THE ASDEX-UPGRADE DIVERTOR PLATES DETERMINED BY THERMOGRAPHY AND CALORIMETRY [J].
HERRMANN, A ;
JUNKER, W ;
GUNTHER, K ;
BOSCH, S ;
KAUFMANN, M ;
NEUHAUSER, J ;
PAUTASSO, G ;
RICHTER, T ;
SCHNEIDER, R .
PLASMA PHYSICS AND CONTROLLED FUSION, 1995, 37 (01) :17-29
[10]   THE ITER DIVERTOR CONCEPT [J].
JANESCHITZ, G ;
BORRASS, K ;
FEDERICI, G ;
IGITKHANOV, Y ;
KUKUSHKIN, A ;
PACHER, HD ;
PACHER, GW ;
SUGIHARA, M .
JOURNAL OF NUCLEAR MATERIALS, 1995, 220 :73-88