Seismic response control of base-isolated buildings using tuned mass damper

被引:32
|
作者
Stanikzai, Mohammad Hamayoun [1 ]
Elias, Said [2 ]
Matsagar, Vasant A. [3 ]
Jain, Arvind K. [3 ]
机构
[1] Old Dominion Univ, Dept Civil & Environm Engn, Norfolk, VA USA
[2] Univ Iceland, Earthquake Engn Res Ctr, Reykjavik, Iceland
[3] Indian Inst Technol IIT Delhi, Dept Civil Engn, New Delhi, India
关键词
Base-isolated buildings; bearing displacement; top floor acceleration; tuned mass damper; hybrid vibration controller; SYSTEMS;
D O I
10.1080/13287982.2019.1635307
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Earthquake response mitigation of base-isolated (BI) buildings with a tuned mass damper (TMD) is investigated. Two-dimensional reinforced concrete buildings having multiple degrees of freedom are numerically modelled. The placement of a TMD is varied on different floor levels and the building response under earthquake excitations is studied. The laminated rubber bearing (LRB), lead rubber bearing (N-Z), friction pendulum system and resilient-friction base isolator (R-FBI) are used as isolation systems for the buildings with 5, 10 and 15 floor levels. Newmark's step-by-step method of integration is used for solving differential equations of motion of the coupled buildings. Installation of a TMD at different story of the BI buildings mitigates the acceleration at the top level and displacement at bearings. It is found that at increased time period of the isolators the effectiveness of the TMD is reduced. Further, for low-rise buildings, the placement of TMD has no significant role in reducing the response of the buildings. However, the efficiency of TMD placement is more noticeable for buildings with a larger number of stories.
引用
收藏
页码:310 / 321
页数:12
相关论文
共 50 条
  • [1] Seismic response control of base-isolated buildings using multiple tuned mass dampers
    Stanikzai, Mohammad Hamayoun
    Elias, Said
    Matsagar, Vasant A.
    Jain, Arvind K.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (03):
  • [2] Assessment of the tuned mass damper inerter for seismic response control of base-isolated structures
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (02):
  • [3] Seismic performance improvement of base-isolated structures using a semi-active tuned mass damper
    Wang, Liangkun
    Nagarajaiah, Satish
    Shi, Weixing
    Zhou, Ying
    ENGINEERING STRUCTURES, 2022, 271
  • [4] Seismic response control of base-isolated structures with fluid inerter damper
    Akhare, Ashish R.
    INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2023, 13 (01) : 1 - 21
  • [5] Seismic Response Mitigation of Base-Isolated Buildings
    Stanikzai, Mohammad Hamayoun
    Elias, Said
    Rupakhety, Rajesh
    APPLIED SCIENCES-BASEL, 2020, 10 (04):
  • [6] STOCHASTIC SEISMIC RESPONSE OF BASE-ISOLATED BUILDINGS
    Jacob, C.
    Sepahvand, K.
    Matsagar, V. A.
    Marburg, S.
    INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2013, 5 (01)
  • [7] THE EFFECT OF TUNED-MASS DAMPERS ON THE SEISMIC RESPONSE OF BASE-ISOLATED STRUCTURES
    TSAI, HC
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 1995, 32 (8-9) : 1195 - 1210
  • [8] A Novel Approach for Vibration Control of Base-Isolated Structures Under Seismic Load Using a Tuned Mass Damper-Clutching Inerter
    Kiran, K. K.
    Al-Osta, Mohammed A.
    Ahmad, Shamsad
    Bahraq, Ashraf A.
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2024, 12 (07) : 8737 - 8757
  • [9] Optimum design for more effective tuned mass damper system and its application to base-isolated buildings
    Xiang, P.
    Nishitani, A.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (01): : 98 - 114
  • [10] Effect of tuned mass damper on displacement demand of base-isolated structures
    Taniguchi, Tomoyo
    Der Kiureghian, Armen
    Melkumyan, Mikayel
    ENGINEERING STRUCTURES, 2008, 30 (12) : 3478 - 3488