Ultra-trace plutonium determination in small volume seawater by sector field inductively coupled plasma mass spectrometry with application to Fukushima seawater samples

被引:35
|
作者
Bu, Wenting [1 ,2 ]
Zheng, Jian [2 ]
Guo, Qiuju [1 ]
Aono, Tatsuo [3 ]
Tagami, Keiko [2 ]
Uchida, Shigeo [2 ]
Tazoe, Hirofumi [4 ]
Yamada, Masatoshi [4 ]
机构
[1] Peking Univ, Sch Phys, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
[2] Natl Inst Radiol Sci, Res Ctr Radiat Protect, Inage Ku, Chiba 2638555, Japan
[3] Natl Inst Radiol Sci, Fukushima Project Headquarters, Inage Ku, Chiba 2638555, Japan
[4] Hirosaki Univ, Inst Radiat Emergency Med, Dept Radiat Chem, Hirosaki, Aomori 0368564, Japan
基金
中国国家自然科学基金;
关键词
Plutonium; Seawater; Anion-exchange chromatography; SF-ICP-MS; FDNPP; NUCLEAR-POWER-PLANT; PU-240/PU-239; ISOTOPIC-RATIOS; PU ISOTOPES; ATOM RATIOS; PACIFIC-OCEAN; ICP-MS; RADIONUCLIDES; CS-137; SEPARATION; IMPACTS;
D O I
10.1016/j.chroma.2014.02.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Long-term monitoring of Pu isotopes in seawater is required for assessing Pu contamination in the marine environment from the Fukushima Dai-ichi Nuclear Power Plant accident. In this study, we established an accurate and precise analytical method based on anion-exchange chromatography and SF-ICP-MS. This method was able to determine Pu isotopes in seawater samples with small volumes (20-60L). The U decontamination factor was 3 x 10(7)-1 x 10(8), which provided sufficient removal of interfering U from the seawater samples. The estimated limits of detection for (PU)-P-239 and Pu-240 were 0.11 fgmL(-1) and 0.08 fg mL(-1), respectively, which corresponded to 0.01 mBq m(-3) for (PU)-P-239 and 0.03 mBq m(-3) for (240)pu when a 20 L volume of seawater was measured. We achieved good precision (2.9%) and accuracy (0.8%) for measurement of the (PU)-P-240/2(39)PU atom ratio in the standard Pu solution with a (PU)-P-239 concentration of 11 fg mL(-1) and Pu-240 concentration of 2.7 fg mL(-1). Seawater reference materials were used for the method validation and both the Pu239+240 activities and Pu-240/Pu-239 atom ratios agreed well with the expected values. Surface and bottom seawater samples collected off Fukushima in the western North Pacific since March 2011 were analyzed. Our results suggested that there was no significant variation of the Pu distribution in seawater in the investigated areas compared to the distribution before the accident. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 50 条
  • [1] Plutonium determination in seawater by inductively coupled plasma mass spectrometry: A review
    Cao, Liguo
    Bu, Wenting
    Zheng, Jian
    Pan, Shaoming
    Wang, Zhongtang
    Uchida, Shigeo
    TALANTA, 2016, 151 : 30 - 41
  • [2] Rapid determination of ultra-trace plutonium in large volume of urine samples by tandem quadrupole inductively coupled plasma-mass spectrometry
    Wu, Yang
    Xu, Yihong
    Xing, Shan
    Dai, Xiongxin
    Yuan, Ni
    Luo, Maoyi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 184
  • [3] Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry
    Lindahl, Patric
    Keith-Roach, Miranda
    Worsfold, Paul
    Choi, Min-Seok
    Shin, Hyung-Seon
    Lee, Sang-Hoon
    ANALYTICA CHIMICA ACTA, 2010, 671 (1-2) : 61 - 69
  • [4] Determination of low-level plutonium in seawater by sector field inductively coupled plasma mass spectrometry: method validation
    Vassileva, Emilia
    Han, Eunmi
    Levy, Isabelle
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (09) : 7898 - 7910
  • [5] Determination of low-level plutonium in seawater by sector field inductively coupled plasma mass spectrometry: method validation
    Emilia Vassileva
    Eunmi Han
    Isabelle Levy
    Environmental Science and Pollution Research, 2017, 24 : 7898 - 7910
  • [6] Determination of ultra-trace elements in snow samples by inductively coupled plasma source sector field mass spectrometry using ultrasonic nebulization
    Bensimon, M
    Bourquin, J
    Parriaux, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (06) : 731 - 734
  • [8] Determination of phosphate in seawater by ion chromatography inductively coupled plasma sector field mass spectrometry
    Cheong, Chikako
    Miura, Tsutomu
    Nonose, Naoko
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2021, 19 (10): : 682 - 691
  • [9] Determination of plutonium and americium in environmental samples by inductively coupled plasma sector field mass spectrometry and alpha spectrometry
    Varga, Zsolt
    Suranyi, Gergely
    Vajda, Nora
    Stefanka, Zsolt
    MICROCHEMICAL JOURNAL, 2007, 85 (01) : 39 - 45
  • [10] Determination of ultra-trace plutonium by online high-speed countercurrent chromatography coupled with inductively coupled plasma mass spectrometry
    Wu, JF
    Jin, YR
    Zhou, GQ
    Zhang, LX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (10) : 1397 - 1400