Nanoporous cobalt oxide nanowires for non-enzymatic electrochemical glucose detection

被引:111
作者
Kang, Luqi [1 ]
He, Daiping [1 ]
Bie, Lili [1 ]
Jiang, Ping [1 ]
机构
[1] Chongqing Normal Univ, Coll Chem, Key Lab Green Synth & Applicat, Chongqing 401331, Peoples R China
关键词
Nanoporous Co3O4 nanowires; Hydrothermal growth; Calcination; Non enzymatic; Glucose detection; CO3O4; NANOFIBERS; SENSOR; NANOPARTICLES; FABRICATION; NANOTUBES;
D O I
10.1016/j.snb.2015.06.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nanoporous Co3O4 nanowires (NCoNWs) were synthesized via a two-step process with hydrothermal growth of cobalt nanowires (NWs) precursors and subsequent calcination of corresponding precursors in air. The structures and morphologies of the resulting cobalt NWs precursors and NCoNWs were characterized by X-ray diffraction (XRD), scanning electron microscopic (SEM) and transmission electron microscopic (TEM). NCoNWs show high electrocatalytic activity toward glucose oxidation in alkaline medium and be used for non-enzymatic electrochemical detection of glucose. The sensor displays a high sensitivity of 300.8 mu A mM(-1) cm(-2), a low detection limit of 5 mu M (S/N =3), and a wide linear dynamic range (5.0 x 10(-6)-5.7 x 10(-4) M). Furthermore, the sensor exhibits a high selectivity for glucose against the common interferences including ascorbic acid, uric acid and dopamine which co-exist with glucose in human serum samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:888 / 894
页数:7
相关论文
共 33 条
[21]   A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides [J].
Rahman, Md. Mahbubur ;
Ahammad, A. J. Saleh ;
Jin, Joon-Hyung ;
Ahn, Sang Jung ;
Lee, Jae-Joon .
SENSORS, 2010, 10 (05) :4855-4886
[22]   Ordered mesoporous metal oxides: synthesis and applications [J].
Ren, Yu ;
Ma, Zhen ;
Bruce, Peter G. .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (14) :4909-4927
[23]   A non-enzymatic amperometric sensor for glucose based on cobalt oxide nanoparticles [J].
Sattarahmady, N. ;
Heli, H. .
JOURNAL OF EXPERIMENTAL NANOSCIENCE, 2012, 7 (05) :529-546
[24]   A Cheap Amperometric and Optical Sensor for Glucose Determination [J].
Scavetta, E. ;
Ballarin, B. ;
Tonelli, D. .
ELECTROANALYSIS, 2010, 22 (04) :427-432
[25]   Potentiometric sensors based on the inductive effect on the pKa of poly(aniline):: A nonenzymatic glucose sensor [J].
Shoji, E ;
Freund, MS .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (14) :3383-3384
[26]   Graphene Oxide: Intrinsic Peroxidase Catalytic Activity and Its Application to Glucose Detection [J].
Song, Yujun ;
Qu, Konggang ;
Zhao, Chao ;
Ren, Jinsong ;
Qu, Xiaogang .
ADVANCED MATERIALS, 2010, 22 (19) :2206-2210
[27]   Raman scattering and high temperature ferromagnetism of Mn-doped ZnO nanoparticles [J].
Wang, J. B. ;
Huang, G. J. ;
Zhong, X. L. ;
Sun, L. Z. ;
Zhou, Y. C. ;
Liu, E. H. .
APPLIED PHYSICS LETTERS, 2006, 88 (25)
[28]   Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition [J].
Wei, A. ;
Sun, X. W. ;
Wang, J. X. ;
Lei, Y. ;
Cai, X. P. ;
Li, C. M. ;
Dong, Z. L. ;
Huang, W. .
APPLIED PHYSICS LETTERS, 2006, 89 (12)
[29]  
Wu J. W., 2014, SENSOR LETT, V1, P69
[30]   Nonenzymatic glucose sensor based on ultrasonic-electrode position of bimetallic PtM (M = Ru, Pd and Au) nanoparticles on carbon nanotubes-ionic liquid composite film [J].
Xiao, Fei ;
Zhao, Faqiong ;
Mei, Deping ;
Mo, Zhirong ;
Zeng, Baizhao .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3481-3486