Fuzzy model based on-line stator winding turn fault detection for induction motors

被引:0
|
作者
Wang Xu-hong [1 ]
He Yi-gang [2 ]
机构
[1] Changsha Univ Sci & Technol, Coll Elect & Informat Engn, Changsha, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha, Hunan 410012, Peoples R China
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A fuzzy model based on-line turn fault detection approach for induction motors is presented in this paper. Two T-S fuzzy models are employed to detect turn fault, one is used to estimate the fault severity, the other is used to determine the exact number of fault turns. During fuzzy modeling, a fuzzy clustering algorithm based on similarity assessing is proposed to determine the optimal structure of the model and real-coded genetic algorithm (GA) is adopted to online optimize model parameters. All these techniques make the fuzzy model compact and accurate. Based on it, Experiments are carried out on a special rewound laboratory induction motor, the results show T-S fuzzy model based diagnosis model determines the shorted turns exactly, and is more effective than the forward neural network based diagnosis model under the condition of detecting a slowly developing turn fault.
引用
收藏
页码:838 / 843
页数:6
相关论文
共 50 条
  • [11] Detection of stator-winding turn-to-turn faults in induction motors, based on virtual instrumentation
    Zamarron, A.
    Arjona, M. A.
    INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 2010, 47 (01) : 63 - 72
  • [12] Novel detection method of stator winding inter-turn short circuit fault in induction motors
    School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, China
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2008, 21 (73-79):
  • [13] Stator winding inter-turn insulation fault detection in induction motors by symmetrical components method
    Ballal, M. S.
    Suryawanshi, H. M.
    Mishra, Mahesh K.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2008, 36 (07) : 741 - 753
  • [14] Voltage-current locus-based stator winding inter-turn fault detection in induction motors
    Dongare, Ujwala V.
    Umre, Bhimrao S.
    Ballal, Makarand S.
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2023, 51 (06) : 2889 - 2911
  • [15] Apparent impedance angle based detection of stator winding inter-turn short circuit fault in induction motors
    Xu, BQ
    Li, HM
    Sun, LL
    2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS, 2003, : 1118 - 1125
  • [16] Detection of turn to turn faults in stator winding with axial magnetic flux in induction motors
    Toni, Krstevski
    Slobodan, Mircevski
    Aleksandar, Buckovski
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 826 - +
  • [17] On-line stator fault diagnosis in low voltage induction motors
    Albizu, I
    Zamora, I
    Mazón, AJ
    Saenz, JR
    Tapia, A
    UPEC 2004: 39TH INTERNATIONAL UNIVERSITITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2005, : 504 - 508
  • [18] Stator Winding Fault Detection in Induction Motors Using Wiener Filter
    Abbasi, R.
    Ghazal, M.
    Kazemi, M. G.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (04): : 4800 - 4807
  • [19] Detection for Stator Winding Turn Fault by using Fuzzy Neural Network
    Wang Xu-hong
    He Yi-gang
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, PTS 1 AND 2, 2011, 48-49 : 415 - +
  • [20] Negative sequence admittance average based detection of stator winding inter-turn short circuit fault in induction motors
    Xu, BQ
    Li, HM
    Sun, LL
    ICEMS 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1 AND 2, 2003, : 867 - 870