Cardiac output monitoring by pressure recording analytical method in cardiac surgery

被引:75
作者
Giomarelli, P [1 ]
Biagioli, B [1 ]
Scolletta, S [1 ]
机构
[1] Univ Siena, Dept Surg & Bioengn, Thorac & Cardiovasc Unit, I-53100 Siena, Italy
关键词
cardiac output; monitoring; pulse contour; coronary artery bypass grafting;
D O I
10.1016/j.ejcts.2004.05.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: A less-invasive method has been developed that may provide an alternative to monitor cardiac output from arterial pressure: beat-to-beat values of cardiac output can be obtained by pressure recording analytical method (PRAM). The purpose of this study was to assess the reliability of cardiac output determination by PRAM in cardiac surgery. Methods: Cardiac output was measured in 28 patients undergoing coronary artery bypass grafting at 15 min after anaesthesia induction, 30 min after extracorporeal circulation, 1 and 3 h after arrival in the intensive care unit using thermodilution (ThD) method through a pulmonary artery catheter and PRAM. ThD cardiac output was calculated as the mean of five separate measurements. PRAM provided beat-by-beat cardiac output data continuously throughout the study and the cardiac output values displayed on a dedicated personal computer at each time point were recorded. Correlations were calculated and differences were compared by Bland-Altman analysis. Results: A total of 112 measurements were obtained. Cardiac output ranged from 2.3 to 7.4 l/min, and a good linear correlation (R-2 = 0.78, P < 0.0001) was found between ThD and PRAM. The highest degree of correlation (R-2 = 0.86) was obtained at 3 It after arrival in the intensive care unit. The lower degree of correlation (R-2 = 0.70) was obtained 30 min after extracorporeal circulation. At Bland-Altman analysis, the overall estimates of cardiac output measured by PRAM closely agreed with ThD (mean difference, 0.027; standard deviation, 0.43; limits of agreement, -0.83 and +0.89). Conclusions: Under the studied conditions, our results demonstrate good agreement between PRAM data and ThD measurements, and this new method has shown to be accurate for real-time monitoring of cardiac output in cardiac surgery. Further studies will be required to assess this method in higher-risk patients and in the setting of haemodynamic instability or arrhythmias. This is the first study designed to assess the accuracy of PRAM in cardiac surgery. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:515 / 520
页数:6
相关论文
共 21 条
  • [1] ERRORS IN THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS CAUSED BY RAPID PULMONARY-ARTERY TEMPERATURE DECREASES AFTER CARDIOPULMONARY BYPASS
    BAZARAL, MG
    PETRE, J
    NOVOA, R
    [J]. ANESTHESIOLOGY, 1992, 77 (01) : 31 - 37
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Bottiger BW, 1996, INTENS CARE MED, V22, P312
  • [4] CONTINUOUS VERSUS INTERMITTENT CARDIAC-OUTPUT MEASUREMENT IN CARDIAC SURGICAL PATIENTS UNDERGOING HYPOTHERMIC CARDIOPULMONARY BYPASS
    BOTTIGER, BW
    RAUCH, H
    BOHRER, H
    MOTSCH, J
    SODER, M
    FLEISCHER, F
    MARTIN, E
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (04) : 405 - 411
  • [5] Burton AC, 1962, HDB PHYSIOLOGY 2, VI, P85
  • [6] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [7] Lack of agreement between thermodilution and fick cardiac output in critically ill patients
    Dhingra, VK
    Fenwick, JC
    Walley, KR
    Chittock, DR
    Ronco, JJ
    [J]. CHEST, 2002, 122 (03) : 990 - 997
  • [8] Myocardial and lung injury after cardiopulmonary bypass: Role of interleukin (IL)-10
    Giomarelli, P
    Scolletta, S
    Borrelli, E
    Biagioli, B
    [J]. ANNALS OF THORACIC SURGERY, 2003, 76 (01) : 117 - 123
  • [9] Gödje O, 2002, CRIT CARE MED, V30, P52
  • [10] Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients
    Gonzalez, J
    Delafosse, C
    Fartoukh, M
    Capderou, A
    Straus, C
    Zelter, M
    Derenne, JP
    Similowski, T