Measuring intraocular pressure by different methods

被引:0
作者
Lamparter, J. [1 ]
Hoffmann, E. M. [1 ]
机构
[1] Univ Augenklin Mainz, D-55131 Mainz, Germany
来源
OPHTHALMOLOGE | 2009年 / 106卷 / 08期
关键词
Glaucoma; Tonometry; Intraocular Pressure; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; TRANSPALPEBRAL TONOMETRY; TGDC-01; ICARE;
D O I
10.1007/s00347-009-1971-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Tonometry is the measurement of intraocular pressure (IOP). Normal IOP values range from 10 to 21 mmHg (15.5 mmHg +/- 2 SD). They are influenced by various factors, including the patient's position during measurement, central corneal thickness, corneal diameter and curvature, rigidity of the cornea, and the cornea's state of hydration. Until now, Goldmann applanation tonometry has been seen as the gold standard for intraocular pressure measurement. But many new techniques and devices for determining IOP have been developed, such as noncontact tonometry, the To-no-Pen, the ICare tonometer, dynamic con-tour tonometry, TGDc-01 tonometry, and the ocular response analyzer. The aim of these techniques is to minimize distorting influences to obtain the "true IOP." Several of these methods show advantages in specific situations; however, limitations exist that should be considered when interpreting the obtained IOP results. This article describes the individual methods of measurement and discusses their advantages and disadvantages.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 50 条
[31]   An update on postrefractive surgery intraocular pressure determination [J].
Yao, Wen-Jeng ;
Crossan, Alessa Sook .
CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (04) :258-263
[32]   INTRAOCULAR-PRESSURE DURING MECHANICAL VENTILATION WITH DIFFERENT LEVELS OF POSITIVE END-EXPIRATORY PRESSURE [J].
TEBA, L ;
VITI, A ;
BANKS, DE ;
FONS, A ;
BARBERA, M ;
HSHIEH, PB .
CRITICAL CARE MEDICINE, 1993, 21 (06) :867-870
[33]   Comparison of different devices to measure the intraocular pressure in thyroid-associated orbitopathy [J].
Aylin Garip Kuebler ;
Caroline Wiecha ;
Lukas Reznicek ;
Annemarie Klingenstein ;
Kathrin Halfter ;
Siegfried Priglinger ;
Christoph Hintschich .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 :2025-2032
[34]   Intraocular pressure in keratoconus [J].
Read, Scott A. ;
Collins, Michael J. .
ACTA OPHTHALMOLOGICA, 2011, 89 (04) :358-364
[35]   Comparison of Intraocular Pressure Measurements Using Three Different Methods (Goldmann Applanation Tonometry (GAT), Corvis ST, and iCare) Following Penetrating Keratoplasty [J].
Tziola, Tatiana ;
Tzamalis, Argyrios ;
Koronis, Spyridon ;
Garitsis, Panagiotis ;
Tsinopoulos, Ioannis ;
Ziakas, Nikolaos .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)
[36]   A device for measuring intraocular pressure through the eyelid [J].
Piletskii G.K. .
Biomedical Engineering, 1998, 32 (4) :244-245
[37]   A new electromechanical method for measuring intraocular pressure [J].
Kontiola, A .
DOCUMENTA OPHTHALMOLOGICA, 1997, 93 (03) :265-276
[38]   A new electromechanical method for measuring intraocular pressure [J].
Antti Kontiola .
Documenta Ophthalmologica, 1997, 93 :265-276
[39]   Initial investigations on systems for measuring intraocular pressure [J].
Schnakenberg, U ;
Walter, P ;
Bögel, GV ;
Krüger, C ;
Lüdtke-Handjery, HC ;
Richter, HA ;
Specht, W ;
Ruokonen, P ;
Mokwa, W .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 85 (1-3) :287-291
[40]   Value of Pressure Measurements: Methods and Sources of Errors [J].
Ruefer, F. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (07) :847-U103