Measuring intraocular pressure by different methods

被引:0
作者
Lamparter, J. [1 ]
Hoffmann, E. M. [1 ]
机构
[1] Univ Augenklin Mainz, D-55131 Mainz, Germany
来源
OPHTHALMOLOGE | 2009年 / 106卷 / 08期
关键词
Glaucoma; Tonometry; Intraocular Pressure; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; TRANSPALPEBRAL TONOMETRY; TGDC-01; ICARE;
D O I
10.1007/s00347-009-1971-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Tonometry is the measurement of intraocular pressure (IOP). Normal IOP values range from 10 to 21 mmHg (15.5 mmHg +/- 2 SD). They are influenced by various factors, including the patient's position during measurement, central corneal thickness, corneal diameter and curvature, rigidity of the cornea, and the cornea's state of hydration. Until now, Goldmann applanation tonometry has been seen as the gold standard for intraocular pressure measurement. But many new techniques and devices for determining IOP have been developed, such as noncontact tonometry, the To-no-Pen, the ICare tonometer, dynamic con-tour tonometry, TGDc-01 tonometry, and the ocular response analyzer. The aim of these techniques is to minimize distorting influences to obtain the "true IOP." Several of these methods show advantages in specific situations; however, limitations exist that should be considered when interpreting the obtained IOP results. This article describes the individual methods of measurement and discusses their advantages and disadvantages.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 50 条
[21]   Intraocular Pressure Measurements After Descemet Membrane Endothelial Keratoplasty [J].
Maier, Anna-Karina ;
Gundlach, Enken ;
Pahlitzsch, Milena ;
Gonnermann, Johannes ;
Corkhill, Caitlin ;
Bertelmann, Eckart ;
Joussen, Antonia M. ;
Klamann, Matthias K. J. ;
Torun, Necip .
JOURNAL OF GLAUCOMA, 2017, 26 (03) :258-265
[22]   Hornhautdickenunabhängige Methoden der Messung des AugeninnendrucksMethods of measuring intraocular pressure independently of central corneal thickness [J].
A. Hager ;
W. Wiegand .
Der Ophthalmologe, 2008, 105 :840-844
[23]   Comparison of three tonometers for measuring intraocular pressure in rabbits [J].
Abrams, LS ;
Vitale, S ;
Jampel, HD .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (05) :940-944
[24]   Evaluation of a Contact Lens-Embedded Sensor for Intraocular Pressure Measurement [J].
Twa, Michael D. ;
Roberts, Cynthia J. ;
Karol, Huikai J. ;
Mahmoud, Ashraf M. ;
Weber, Paul A. ;
Small, Robert H. .
JOURNAL OF GLAUCOMA, 2010, 19 (06) :382-390
[25]   Impact of corneal parameters on intraocular pressure measurements in different tonometry methods [J].
Aleksandra Zakrzewska ;
Marta P.Wi?cek ;
Anna Machalińska .
International Journal of Ophthalmology, 2019, (12) :1853-1858
[26]   A Dynamic Tonometer for Measuring Intraocular Pressure [J].
Dikin V.I. ;
Ivanyschev C.V. ;
Kornev N.P. ;
Mikheev A.A. ;
Solomakha V.N. .
Biomedical Engineering, 2013, 47 (03) :130-133
[27]   Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings [J].
Berk, Thomas A. ;
Yang, Patrick T. ;
Chan, Clara C. .
JOURNAL OF GLAUCOMA, 2016, 25 (10) :E897-E904
[28]   Comparison of three methodologies for measuring intraocular pressure in healthy cats [J].
Ricci, Claudia Lizandra ;
Passareli, Joao Victor Goulart Consoni ;
Nascimento, Felipe Franco ;
Kanashiro, Glaucia Prada ;
Zulim, Luis Felipe da Costa ;
Giuffrida, Rogerio ;
Andrade, Silvia Franco .
VETERINARY WORLD, 2024, 17 (08) :1803-1809
[29]   Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness [J].
Carbonaro, F. ;
Andrew, T. ;
Mackey, D. A. ;
Spector, T. D. ;
Hammond, C. J. .
EYE, 2010, 24 (07) :1165-1170
[30]   A Review on Different Tonometers for Intraocular Pressure Measurement After Photo refractive Keratectomy or Small Incision Lenticule Extraction [J].
Chow, Shing Chuen ;
Yeung, Barry Yat Ming .
CLINICAL OPHTHALMOLOGY, 2020, 14 :3305-3323