Tonometry is the measurement of intraocular pressure (IOP). Normal IOP values range from 10 to 21 mmHg (15.5 mmHg +/- 2 SD). They are influenced by various factors, including the patient's position during measurement, central corneal thickness, corneal diameter and curvature, rigidity of the cornea, and the cornea's state of hydration. Until now, Goldmann applanation tonometry has been seen as the gold standard for intraocular pressure measurement. But many new techniques and devices for determining IOP have been developed, such as noncontact tonometry, the To-no-Pen, the ICare tonometer, dynamic con-tour tonometry, TGDc-01 tonometry, and the ocular response analyzer. The aim of these techniques is to minimize distorting influences to obtain the "true IOP." Several of these methods show advantages in specific situations; however, limitations exist that should be considered when interpreting the obtained IOP results. This article describes the individual methods of measurement and discusses their advantages and disadvantages.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 50 条
  • [1] Measuring intraocular pressure
    Okafor, Kingsley C.
    Brandt, James D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (02) : 103 - 109
  • [2] Methods of measuring intraocular pressure independently of central corneal thickness
    Hager, A.
    Wiegand, W.
    OPHTHALMOLOGE, 2008, 105 (09): : 840 - 844
  • [3] New technologies for measuring intraocular pressure
    Garcia-Feijoo, Julian
    Martinez-de-la-Casa, Jose Maria
    Morales-Fernandez, Laura
    Frances, Federico Saenz
    Santos-Bueso, Enrique
    Garcia-Saenz, Sofia
    Mendez-Hernandez, Carmen
    NEW TRENDS IN BASIC AND CLINICAL RESEARCH OF GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE VISUAL SYSTEM, PT B, 2015, 221 : 67 - 79
  • [4] Changes in intraocular pressure after intraocular eye surgery-the influence of measuring technique
    Kovacic, Hrvoje
    Wolfs, Roger C. W.
    Kilic, Emine
    Ramdas, Wishal D.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (06) : 967 - 973
  • [5] Impact of corneal parameters on intraocular pressure measurements in different tonometry methods
    Zakrzewska, Aleksandra
    Wiacek, Marta P.
    Machalinska, Anna
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (12) : 1853 - 1858
  • [6] Comparison of Three Intraocular Pressure Measurement Methods Including Biomechanical Properties of the Cornea
    Smedowski, Adrian
    Weglarz, Beata
    Tarnawska, Dorota
    Kaarniranta, Kai
    Wylegala, Edward
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (02) : 666 - 673
  • [7] Most common mistakes in measuring intraocular pressure
    Markovic, Vujica
    Marjanovic, Ivan
    Krstic, Vera
    Kovacevic, Dragana
    Radovic, Nada
    Gvojie, Alisa
    Jovanovic, Svetlana
    VOJNOSANITETSKI PREGLED, 2009, 66 (07) : 577 - 582
  • [8] Intraocular pressure measurement: A review *
    Da Silva, Filipe
    Lira, Madalena
    SURVEY OF OPHTHALMOLOGY, 2022, 67 (05) : 1319 - 1331
  • [9] Messung des Augeninnendrucks (Tonometrie) mit unterschiedlichen VerfahrenMeasuring intraocular pressure by different methods
    J. Lamparter
    E.M. Hoffmann
    Der Ophthalmologe, 2009, 106 (8): : 676 - 682
  • [10] Intraocular Pressure Measurement after Penetrating Keratoplasty
    Dumitrescu, Otilia-Maria
    Istrate, Sinziana
    Macovei, Mioara-Laura
    Gheorghe, Alina Gabriela
    DIAGNOSTICS, 2022, 12 (02)