On-line monitoring of solutes in dialysate using absorption of ultraviolet radiation: Technique description

被引:47
作者
Fridolin, I [1 ]
Magnusson, M
Lindberg, LG
机构
[1] Linkoping Univ, Univ Hosp, Dept Biomed Engn, SE-58185 Linkoping, Sweden
[2] Linkoping Univ, Univ Hosp, Dept Nephrol, S-58183 Linkoping, Sweden
关键词
hemodialysis; dialysis monitoring; spectrophotometry; ultraviolet; absorption; spent dialysate; dialysis dose; dialysis adequacy; dialysis efficiency; urea; creatinine; uric acid;
D O I
10.1177/039139880202500802
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The aim of this work was to describe a new optical method for monitoring solutes in a spent dialysate using absorption of UV radiation. Method: The method utilises UV-absorbance determined in the spent dialysate using a spectrophotometrical set-up. Measurements were performed both on collected dialysate samples and on-line. During on-line monitoring, a spectrophotometer was connected to the fluid outlet of the dialysis machine, with all spent dialysate passing through a specially-designed cuvette for optical single-wavelength measurements. The concentrations of several substances of various molecular sizes, electrical charge, transport mechanism, etc. were determined in the dialysate and in the blood using standard laboratory techniques. The correlation coefficient between UV-absorbance of the spent dialysate and concentration of the substances in the spent dialysate and in the, blood was calculated from data based on the collected samples. Results: The obtained on-line UV-absorbance curve demonstrates the possibility to follow a single hemodialysis session continuously and to monitor deviations in the dialysator performance using UV-absorbance. The experimental results indicate a very good correlation between UV-absorbance and several small waste solutes removed such as urea, creatinine and uric acid in the spent dialysate and in the blood for every individual treatment at a fixed wavelength of 285 nm. Moreover, a good correlation between the UV-absorbance and substances like potassium, phosphate and beta(2)-microglobulin was obtained. The lowest correlation was achieved for sodium, calcium, glucose, vitamin B-12 and albumin. Conclusions: A technique for on-line monitoring of solutes in the spent dialysate utilising the UV-absorbance was developed. On-line monitoring during a single hemodialysis session exploiting UVabsorbance represents a possibility to follow a single hemodialysis session continuously and monitor deviations in dialysis efficiency (e.g. changes in blood flow and clearance). The UV-absorbance correlates well to the concentration of several solutes known to accumulate in dialysis patients indicating that the technique can be used to estimate the removal of retained substances.
引用
收藏
页码:748 / 761
页数:14
相关论文
共 56 条
  • [1] [Anonymous], COMPLICATIONS DIALYS
  • [2] ASABA H, 1979, CLIN NEPHROL, V11, P257
  • [3] BIOCHEMISTRY OF THE UREMIC SYNDROME
    BAKIR, A
    WILLIAMS, RH
    SHAYKH, M
    DUNEA, G
    DUBIN, A
    [J]. ADVANCES IN CLINICAL CHEMISTRY, 1992, 29 : 61 - 120
  • [4] BHATLA B, 1995, ASAIO J, V41, pM442, DOI 10.1097/00002480-199507000-00048
  • [5] Beyond "adequate dialysis"
    Bosch, JP
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 35 (02) : XLVI - XLVIII
  • [6] COMBINATION OF CONVENTIONAL AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC TECHNIQUES FOR THE ISOLATION OF SO-CALLED UREMIC TOXINS
    BRUNNER, H
    MANN, H
    [J]. JOURNAL OF CHROMATOGRAPHY, 1984, 297 (AUG): : 405 - 416
  • [7] A new biosensor for continuous monitoring of the spent dialysate urea level in standard hemodialysis
    Calzavara, P
    Calconi, G
    Da Rin, G
    Canini, E
    Paolini, F
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (03) : 147 - 150
  • [8] On-line dialysis quantification in acutely ill patients - Preliminary clinical experience with a multipurpose urea sensor monitoring device
    Canaud, B
    Bosc, JY
    Leblanc, M
    Vaussenat, F
    Leray-Moragues, H
    Garred, LJ
    Mathieu-Daude, JC
    Mion, G
    [J]. ASAIO JOURNAL, 1998, 44 (03) : 184 - 190
  • [9] Charra B, 2001, SEMIN DIALYSIS, V14, P8, DOI 10.1046/j.1525-139x.2001.00003.x
  • [10] CLARK WR, 2000, COMPLICATIONS DIALYS, P251