Update on MRI Pulse Sequences for the Knee: Imaging of Cartilage, Meniscus, Tendon, and Hardware

被引:8
作者
Ariyachaipanich, Aticha [1 ,2 ,3 ]
Bae, Won C. [1 ,4 ]
Statum, Sheronda [1 ,4 ]
Chung, Christine B. [1 ,4 ]
机构
[1] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[2] King Chulalongkorn Mem Hosp, Dept Radiol, Bangkok, Thailand
[3] Chulalongkorn Univ, Dept Med, Bangkok, Thailand
[4] VA San Diego Healthcare Syst, Dept Radiol, 3350 Jolla Village Dr,MC-114, San Diego, CA 92161 USA
关键词
quantitative MRI; UTE; T2; T1; rho; osteoarthritis; ULTRASHORT ECHO TIME; T2; RELAXATION-TIME; METAL ARTIFACT REDUCTION; TRABECULAR BONE-STRUCTURE; CRUCIATE LIGAMENT INJURY; DUAL INVERSION-RECOVERY; CONTRAST-ENHANCED MRI; ARTICULAR-CARTILAGE; MAGNETIC-RESONANCE; CALCIFIED CARTILAGE;
D O I
10.1055/s-0037-1599209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) is widely used in the clinical setting as well as for research applications. Since its inception, technical development has broadly progressed as a response to challenges in both the clinical and research settings. Higher magnetic field strength and advances in hardware and software have revolutionized the diagnostic potential of MRI and moved well beyond diagnosis to characterization of tissue metabolism, biochemistry, disease pathogenesis, and material property, to name a few. This article focuses on state-of-the-art clinical and cutting-edge novel pulse sequences applied to knee MRI.
引用
收藏
页码:45 / 62
页数:18
相关论文
共 152 条
[71]  
JOZSA L, 1991, ACTA ANAT, V142, P306
[72]   Diagnosis of Internal Derangement of the Knee at 3.0-T MR Imaging: 3D Isotropic Intermediate-weighted versus 2D Sequences [J].
Jung, Jee Young ;
Yoon, Young Cheol ;
Kwon, Jong Won ;
Ahn, Jin Hwan ;
Choe, Bong-Keun .
RADIOLOGY, 2009, 253 (03) :780-787
[73]   Meniscal Tear Configurations: Categorization With 3D Isotropic Turbo Spin-Echo MRI Compared With Conventional MRI at 3 T [J].
Jung, Joon-Yong ;
Jee, Won-Hee ;
Park, Michael Y. ;
Lee, So-Yeon ;
Kim, Jung-Man .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) :W173-W180
[74]   Bi-exponential T2* analysis of healthy and diseased Achilles tendons: an in vivo preliminary magnetic resonance study and correlation with clinical score [J].
Juras, Vladimir ;
Apprich, Sebastian ;
Szomolanyi, Pavol ;
Bieri, Oliver ;
Deligianni, Xeni ;
Trattnig, Siegfried .
EUROPEAN RADIOLOGY, 2013, 23 (10) :2814-2822
[75]   Structure of the tendon connective tissue [J].
Kannus, P .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2000, 10 (06) :312-320
[76]   Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging-Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T [J].
Kijowski, Richard ;
Davis, Kirkland W. ;
Woods, Michael A. ;
Lindstrom, Mary J. ;
De Smet, Arthur A. ;
Gold, Garry E. ;
Busse, Reed F. .
RADIOLOGY, 2009, 252 (02) :486-495
[77]   Vastly Undersampled Isotropic Projection Steady-State Free Precession Imaging of the Knee: Diagnostic Performance Compared with Conventional MR [J].
Kijowski, Richard ;
Blankenbaker, Donna G. ;
Klaers, Jessica L. ;
Shinki, Kazuhiko ;
De Smet, Arthur A. ;
Block, Walter F. .
RADIOLOGY, 2009, 251 (01) :185-194
[78]   Imaging Near Metal with a MAVRIC-SEMAC Hybrid [J].
Koch, K. M. ;
Brau, A. C. ;
Chen, W. ;
Gold, G. E. ;
Hargreaves, B. A. ;
Koff, M. ;
McKinnon, G. C. ;
Potter, H. G. ;
King, K. F. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) :71-82
[79]   Ultrashort echo imaging of cyclically loaded rabbit patellar tendon [J].
Koff, Matthew F. ;
Pownder, Sarah L. ;
Shah, Parina H. ;
Yang, Lim Wei ;
Potter, Hollis G. .
JOURNAL OF BIOMECHANICS, 2014, 47 (13) :3428-3432
[80]   Quantifying image distortion of orthopedic materials in magnetic resonance imaging [J].
Koff, Matthew F. ;
Shah, Parina ;
Koch, Kevin M. ;
Potter, Hollis G. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) :610-618