Crack closure and stress intensity factor measurements in nodular graphite cast iron using three-dimensional correlation of laboratory X-ray microtomography images

被引:106
作者
Limodin, Nathalie [1 ]
Rethore, Julien [2 ]
Buffiere, Jean-Yves [1 ]
Gravouil, Anthony [2 ]
Hild, Francois [3 ]
Roux, Stephane [3 ]
机构
[1] Inst Natl Sci Appl, CNRS, UMR 5510, MATEIS, F-69621 Villeurbanne, France
[2] Inst Natl Sci Appl, CNRS, UMR 5529, LaMCos, F-69621 Villeurbanne, France
[3] Univ Paris Sud, CNRS, LMT Cachan, ENS Cachan,UPMC,PRES, F-94235 Cachan, France
关键词
X-ray microtomography; 3-D digital image correlation; Stress intensity factors; Nodular graphite cast iron; SHORT FATIGUE-CRACK; STRAIN-MEASUREMENTS; TOMOGRAPHY; GROWTH; BEHAVIOR; ALLOY; VISUALIZATION; NUCLEATION; DAMAGE; SHAPE;
D O I
10.1016/j.actamat.2009.05.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Three-dimensional (3-D) tomographic images of a nodular graphite cast iron obtained using a laboratory X-ray source were used to analyze the opening of a fatigue crack during in situ mechanical loading. Direct image analysis and digital image correlation are utilized to obtain the 3-D morphology and front location of the crack, as well as the displacement fields in the bulk of the specimen. From digital image correlation results it is possible to extract the crack opening displacement (COD) map in the whole sample cross-section and to compute stress intensity factors (SIFs) all along the crack front, even for COD values that are less than the image resolution. The comparison of COD maps with local values of the SIF enabled for an estimation of the opening SIF (K-op) equal to 6 MPa m(1/2). (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:4090 / 4101
页数:12
相关论文
共 32 条
  • [21] Analysis and Artifact Correction for Volume Correlation Measurements Using Tomographic Images from a Laboratory X-ray Source
    Limodin, N.
    Rethore, J.
    Adrien, J.
    Buffiere, J. -Y.
    Hild, F.
    Roux, S.
    EXPERIMENTAL MECHANICS, 2011, 51 (06) : 959 - 970
  • [22] Investigating the three-dimensional myocardial micro-architecture in the laminar structure using X-ray phase-contrast microtomography
    Wang, Shunli
    Wang, Yan
    Li, Zhaorui
    Zhao, Yifei
    Zhang, Ying
    Varray, Francois
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Quantitative characterization of three-dimensional pore structure in hardened cement paste using X-ray microtomography combined with centrifuge driven metal alloy intrusion
    Qian, Rusheng
    Zhang, Yunsheng
    Liu, Cheng
    Yang, Lin
    Liu, Guojian
    She, Wei
    MATERIALS CHARACTERIZATION, 2018, 145 : 277 - 283
  • [24] Measuring the stress field around an evolving crack in tensile deformed Mg AZ31 using three-dimensional X-ray diffraction
    Oddershede, Jette
    Camin, Bettina
    Schmidt, Soren
    Mikkelsen, Lars P.
    Sorensen, Henning Osholm
    Lienert, Ulrich
    Poulsen, Henning Friis
    Reimers, Walter
    ACTA MATERIALIA, 2012, 60 (08) : 3570 - 3580
  • [25] Three-Dimensional (3D) Microstructure-Based Modeling of a Thermally-Aged Cast Duplex Stainless Steel Based on X-ray Microtomography, Nanoindentation and Micropillar Compression
    Zhang, Qingdong
    Zhu, Kai
    Singaravelu, Arun Sundar S.
    Sun, Weizhao
    Jing, Tao
    Chawla, Nikhilesh
    METALS, 2019, 9 (06)
  • [26] Three-dimensional (3D) morphological and liquid absorption assessment of sustainable biofoams absorbents using X-ray microtomography analysis
    Federico, Carlos Eloy
    Wu, Qiong
    Olsson, Richard T.
    Capezza, Antonio J.
    POLYMER TESTING, 2022, 116
  • [27] Three-dimensional curving of crystal planes in wide bandgap semiconductor wafers visualized using a laboratory X-ray diffractometer
    Yao, Yongzhao
    Sato, Koji
    Sugawara, Yoshihiro
    Okada, Narihito
    Tadatomo, Kazuyuki
    Sasaki, Kohei
    Kuramata, Akito
    Ishikawa, Yukari
    JOURNAL OF CRYSTAL GROWTH, 2022, 583
  • [28] X-ray microtomography as a fast three-dimensional imaging technology using a CCD camera coupled with a CdWO4 single-crystal scintillator
    Lee, HR
    Lai, B
    Yun, WB
    Mancini, DC
    Cai, ZH
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 257 - 264
  • [29] Three-Dimensional Investigation of Free-Edge Effects in Laminate Composites Using X-ray Tomography and Digital Volume Correlation
    Lecomte-Grosbras, P.
    Rethore, J.
    Limodin, N.
    Witz, J. -F.
    Brieu, M.
    EXPERIMENTAL MECHANICS, 2015, 55 (01) : 301 - 311
  • [30] Quantitative analysis of three-dimensional fatigue crack path selection in Mg alloy WE43 using high-energy X-ray diffraction microscopy
    Greeley, Duncan A.
    Adams, Jacob F.
    Kenesei, Peter
    Spear, Ashley D.
    Allison, John E.
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2024, 47 (04) : 1150 - 1171