Contributions of Advanced Techniques to the Success and Safety of Transvenous Leads Extraction

被引:29
作者
Marijon, Eloi [1 ]
Boveda, Serge [1 ]
De Guillebon, Maxime [2 ]
Jacob, Sophie [3 ]
Vahdat, Olivier [4 ]
Barandon, Laurent [5 ]
Combes, Nicolas [1 ]
Sidobre, Laurent [4 ]
Albenque, Jean-Paul [1 ]
Clementy, Jacques [2 ]
Bordachar, Pierre [2 ]
机构
[1] Clin Pasteur, Dept Rythmol, F-31076 Toulouse 3, France
[2] Hop Haut Leveque, Dept Cardiol, Pessac, France
[3] IRSN, Dept Epidemiol, Fontenay Aux Roses, France
[4] Clin Pasteur, Dept Chirurg Cardiothorac, F-31076 Toulouse, France
[5] Hop Haut Leveque, Dept Chirurg Cardiaque, Pessac, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷
关键词
lead extraction; pacing lead complication; pacing lead infection; implantable cardioverter defibrillator; DEFIBRILLATOR LEADS; PACEMAKER; SHEATH;
D O I
10.1111/j.1540-8159.2008.02225.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We measured the proportion of intravascular leads, which can be extracted by simple traction versus with newer techniques, and examined 'the overall safety and success rate of lead extractions. Methods: Between nuary 2005 and December 2007, 311 consecutive patients (mean age = 70 +/- 14 years, 79% men) underwent extractions of 250 atria], 318 ventricular' and 22 coronary sinus leads, in the surgical facilities of two experienced medical centers, under general anesthesia, at a mean of 7.2 +/- 5.1 years (range 0.1-27.0) after lead implantation. Infection was the indication for extraction in 67.5% of cases. Complementary techniques were used when simple extraction with a locking stylet was unsuccessful. Results: Simple traction, with or without a locking stylet, allowed the complete removal in 27.0% (95% confidence interval [CI] 22.1-31.9) of patients. A mechanical sheath, loser sheath, and/or lasso catheter were used in the remaining patients. The overall extraction success rate was 89.7% (95% CI 86.3-93.1). There was one procedure-related death (0.3%; 95% CI 0.0-1.0). Among five other deaths occurring within 10 days after the procedure, four were due to septic shock. Duration of lead implantation was the strongest independent predictor of major adverse events (P = 0,002) and incomplete lead extraction (P = 0.005). Conclusion: In contrast with simple traction, advanced techniques allowed the complete extraction of nearly 90% of leads. In experienced hands and with surgical back-up, these techniques were safe. Patients presenting with infected implanted cardiac devices suffered a high rate of major adverse despite complete extraction of the lead(s). (PACE 2009; 32:S38-S41)
引用
收藏
页码:S38 / S41
页数:4
相关论文
共 8 条
[1]   Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads [J].
Bongiorni, Maria Grazia ;
Soldati, Ezio ;
Zucchelli, Giulio ;
Di Cori, Andrea ;
Segreti, Luca ;
De Lucia, Raffaele ;
Solarino, Gianluca ;
Balbarini, Alberto ;
Marzilli, Mario ;
Mariani, Mario .
EUROPEAN HEART JOURNAL, 2008, 29 (23) :2886-2893
[2]   Extraction of pacemaker and implantable cardioverter defibrillator leads: Patient and lead characteristics in relation to the requirement of extraction tools [J].
Bracke, F ;
Meijer, A ;
Van Gelder, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (07) :1037-1040
[3]   Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads [J].
Esposito, M ;
Kennergren, C ;
Holmström, N ;
Nilsson, S ;
Eckerdal, J ;
Thomsen, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (05) :548-558
[4]   Laser-assisted lead extraction: the European experience [J].
Kennergren, C. ;
Bucknall, C. A. ;
Butter, C. ;
Charles, R. ;
Fuhrer, J. ;
Grosfeld, M. ;
Tavernier, R. ;
Morgado, T. B. ;
Mortensen, P. ;
Paul, V. ;
Richter, P. ;
Schwartz, T. ;
Wellens, F. .
EUROPACE, 2007, 9 (08) :651-656
[5]  
Love CJ, 2000, PACE, V23, P544
[6]   AUTOPSY FINDINGS WITH PERMANENT PERVENOUS PACEMAKERS [J].
ROBBOY, SJ ;
HARTHORNE, JW ;
LEINBACH, RC ;
SANDERS, CA ;
AUSTEN, WG .
CIRCULATION, 1969, 39 (04) :495-+
[7]   Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003 [J].
Voigt, Andrew ;
Shalaby, Alaa ;
Saba, Samir .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (03) :590-591
[8]   Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (PLEXES) trial [J].
Wilkoff, BL ;
Byrd, CL ;
Love, CJ ;
Hayes, DL ;
Sellers, TD ;
Schaerf, R ;
Parsonnet, V ;
Epstein, LM ;
Sorrentino, RA ;
Reiser, C .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1671-1676