Effect of compliant flooring on impact force during falls on the hip

被引:47
作者
Laing, Andrew C. [1 ]
Tootoonchi, Iman [1 ]
Hulme, Paul A. [1 ]
Robinovitch, Stephen N. [1 ]
机构
[1] Simon Fraser Univ, Fac Sci Appl, Sch Kinesiol, Injury Prevent & Mobil Lab, Burnaby, BC V5A 1S6, Canada
关键词
falls; hip fracture; osteoporosis; injury prevention; floor design;
D O I
10.1002/jor.20172
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Compliant flooring represents a promising but understudied strategy for reducing impact force and hip fracture risk due to falls in high-risk environments such as nursing homes, hospitals, gymnasiums, and senior centers. We conducted "pelvis release experiments" with young women (n = 15) to determine whether floor stiffness influences peak hip impact force during safe, low-height falls. During the trials, we used a pelvic sling and electromagnet to lift and instantly release the participant from a height of 5 cm above a force plate, which measured the force applied to the hip region during impact. Trials were conducted for rigid floor conditions and with layers of ethylene vinyl acetate foam rubber overlying the floor that we regarded as firm (1.5-cm thick; stiffness-263 kN/m), semifirm (4.5-cm thick; stiffness=95 kN/m), semisoft (7.5-cm thick: stiffness 67 kN/m), and soft (10.5-cm thick; stiffness = 59 kN/m). When compared to the rigid condition, peak hip impact force averaged 8% lower in the firm condition and 15% lower in the semifirm condition. Peak forces were not significantly different between the semifirm, semisoft, and soft floor conditions, indicating that a 4.5 cm-thick foam mat provides nearly the same force attenuation as a 10.5 cm-thick mat. These results support the need for laboratory experiments to measure the effect of floor stiffness on postural stability and for clinical trials to determine the effect of compliant flooring on hip fracture incidence in high-risk environments. (c) 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:1405 / 1411
页数:7
相关论文
共 25 条
[1]   The Penn State safety floor: Part II - Reduction of fall-related peak impact forces on the femur [J].
Casalena, JA ;
Badre-Alam, A ;
Ovaert, TC ;
Cavanagh, PR ;
Streit, DA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04) :527-532
[2]   EFFECTS OF LOADING RATE ON STRENGTH OF THE PROXIMAL FEMUR [J].
COURTNEY, AC ;
WACHTEL, EF ;
MYERS, ER ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1994, 55 (01) :53-58
[3]   Epidemiology and outcomes of osteoporotic fractures [J].
Cummings, SR ;
Melton, LJ .
LANCET, 2002, 359 (9319) :1761-1767
[4]   Measurement of impact force, simulation of fall and hip fracture [J].
Gardner, TN ;
Simpson, AHRW ;
Booth, C ;
Sprukkelhorst, P ;
Evans, M ;
Kenwright, J ;
Evans, JG .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (01) :57-65
[5]   RISK-FACTORS FOR FALLS AS A CAUSE OF HIP FRACTURE IN WOMEN [J].
GRISSO, JA ;
KELSEY, JL ;
STROM, BL ;
CHIU, GY ;
MAISLIN, G ;
OBRIEN, LA ;
HOFFMAN, S ;
KAPLAN, F .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (19) :1326-1331
[6]  
HAYES WC, 1996, BONE, V18, P77
[7]  
Jaglal SB, 1996, CAN J SURG, V39, P105
[8]   Biomechanics of fall arrest using the upper extremity: age differences [J].
Kim, KJ ;
Ashton-Miller, JA .
CLINICAL BIOMECHANICS, 2003, 18 (04) :311-318
[9]   IMPACT ATTENUATION OF FLOOR COVERINGS IN SIMULATED FALLING ACCIDENTS [J].
MAKI, BE ;
FERNIE, GR .
APPLIED ERGONOMICS, 1990, 21 (02) :107-114
[10]   GROUCHO RUNNING [J].
MCMAHON, TA ;
VALIANT, G ;
FREDERICK, EC .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (06) :2326-2337